QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 6,901–7,000 of 14,770
Home-based screening tools for amblyopia: a systematic review
Sii, S. S. Z., Chean, C. S., Kuht, H. J., Bunce, C., Thomas, M. G., & Rufai, S. R. (2023) · Eye · doi:10.1038/s41433-023-02412-3 · Cited by 14
Al-baker, B., Alkalaly, A., Ayoub, A. F., Ju, X., & Mossey, P. A. (2023) · European Journal of Orthodontics · doi:10.1093/ejo/cjac077 · Cited by 16
Xing, H., Jiang, Z., Wu, Y., Ou, S., Qin, J., Xue, L., & Wu, W. (2023) · International Urology and Nephrology · doi:10.1007/s11255-023-03593-2 · Cited by 15
Shafti, V., Azarboo, A., Ghaemi, M., Gargari, O. K., & Madineh, E. (2023) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2023.05.039 · Cited by 14
Liu, M., Qiu, H., Zhang, W., Mei, T., Tang, S., Gao, Y., Zhu, Y., Huang, X., & Yu, H. (2023) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16240 · Cited by 16
Mahajan, M., Prasad, M. L., Kumar, P., Kumar, A., Chatterjee, N., Singh, S., Marandi, S., & Prasad, M. K. (2023) · Infection and Chemotherapy · doi:10.3947/ic.2023.0014 · Cited by 14
Li, X., Wang, L., Guo, P., Sun, Q., Zhang, Y., Chen, C., & Zhang, Y. (2023) · Annals of Nuclear Medicine · doi:10.1007/s12149-023-01856-7 · Cited by 14
Allergic Fungal Rhinosinusitis in Europe: Literature Review and Own Experience
Kokoszka, M., Stryjewska‐Makuch, G., Kantczak, A., Górny, D., & Glück, J. (2023) · International Archives of Allergy and Immunology · doi:10.1159/000531017 · Cited by 14
The Human Body as an Ethanol-Producing Bioreactor—The Forensic Impacts
Šoša, I. (2023) · Fermentation · doi:10.3390/fermentation9080738 · Cited by 15
Dondi, F., Antonelli, A., Suardi, N. R., Guerini, A. E., Albano, D., Lucchini, S., Camoni, L., Treglia, G., & Bertagna, F. (2023) · Cancers · doi:10.3390/cancers15174404 · Cited by 14
Tian, X., Zhao, J., Song, Y., Wang, Q., Li, M., Liu, J., & Zeng, X. (2023) · Rheumatology and Immunology Research · doi:10.2478/rir-2023-0019 · Cited by 14
Moretti, A., Kovacevic, B., Vilmann, P., Annema, J. T., & Korevaar, D. A. (2023) · Lung Cancer · doi:10.1016/j.lungcan.2023.107391 · Cited by 14
Shufen, C., Jinmin, L., Xiaohui, Z., & Bin, G. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06926-5 · Cited by 14
A systematic review on removal of osseointegrated implants: un update
Tafuri, G., Santilli, M., Manciocchi, E., Rexhepi, I., D’Addazio, G., Caputi, S., & Sinjari, B. (2023) · BMC Oral Health · doi:10.1186/s12903-023-03438-5 · Cited by 18
van der Hulst, H. J., Jansen, R. W., Vens, C., Bos, P., Schats, W., de Jong, M. C., Martens, R. M., Bodalal, Z., Beets‐Tan, R. G. H., van den Brekel, M. W. M., et al. (2023) · Cancers · doi:10.3390/cancers15205077 · Cited by 15
Chang, C.-T., Chan, T., Yu, H., & Yu, K. (2023) · RMD Open · doi:10.1136/rmdopen-2023-003498 · Cited by 14
Diller, G., Gerwing, M., Grazioli, S. B., De-Torres-Alba, F., Radke, R., Vormbrock, J., Baumgartner, H., Kaleschke, G., & Orwat, S. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13020631 · Cited by 16
A meta‐analysis of diabetes risk prediction models applied to prediabetes screening
Liu, Y., Yu, S., Feng, W., Mo, H., Hua, Y., Zhang, M., Zhu, Z., Zhang, X., Wu, Z., Zheng, L., et al. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15457 · Cited by 15
Parra-Medina, R. S., Castañeda-González, J. P., Chaves-Cabezas, V., Álzate, J. P., & Cháves, J. J. (2024) · Pathology - Research and Practice · doi:10.1016/j.prp.2024.155276 · Cited by 14
Cavion, C. C., Altmayer, S., Forte, G. C., Andrade, R. G. F., Hochhegger, D. R., Francisco, M. Z., Camargo, C., Patel, P., & Hochhegger, B. (2024) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.230241 · Cited by 14
Jin, M. X., Qin, P. P., Xia, A. W. L., Kan, R. L. D., Zhang, B. B. B., Tang, A. H. P., Li, A. S. M., Lin, T. T. Z., Giron, C. G., Pei, J. J., et al. (2024) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2024.105695 · Cited by 16
Thermal mapping the eye: A critical review of advances in infrared imaging for disease detection
Persiya, J., & Sasithradevi, A. (2024) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2024.103867 · Cited by 14
Daqqaq, T. S., Alhasan, A. S., & Ghunaim, H. A. (2024) · Neurosciences · doi:10.17712/nsj.2024.2.20230103 · Cited by 16
Shujaat, S., Alfadley, A. A., Morgan, N., Jamleh, A. O., Riaz, M., Aboalela, A. A., & Jacobs, R. (2024) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.13352 · Cited by 14
Cox, E., Wade, R., Hodgson, R. M., Fulbright, H., Phung, T. H., Meader, N., Walker, S., Rothery, C., & Simmonds, M. C. (2023) · Health Technology Assessment · doi:10.3310/ydsl3294 · Cited by 15
Automated Diagnosis of Alzheimer’s Disease Using OCT and OCTA: A Systematic Review
Turkan, Y., Faik Boray, T. E. K., Arpaci, F., Arslan, O., Toslak, D., Bulut, M., & Yaman, A. (2024) · IEEE Access · doi:10.1109/access.2024.3434670 · Cited by 17
“We did not use QUADAS-2 [65] for bias and validity analysis in our study because its construct validity and the reliability of its items for measuring study quality have not been confirmed [66], particularly in Alzheimer’s disease diagnostic accuracy analyses where sample sizes are typically small.”
MethodAhmed, A. S., Ahmed, S. S., Mohamed, S., Salman, N. E., Humidan, A. A. M., Ibrahim, R. F., Salim, R. S., Elamir, A. A. M., & Hakim, E. M. (2024) · Cureus · doi:10.7759/cureus.66453 · Cited by 22
“As for the risk of bias assessment, the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used, which is a tool used for the assessment of the risk of bias and applicability in systematic reviews of primary diagnostic test accuracy studies [15].”
MethodMahmoudi, S., & Moghaddasi, A. H. S. (2024) · Expert Review of Anti-infective Therapy · doi:10.1080/14787210.2024.2389876 · Cited by 14
“(2) Studies that included participants already diagnosed with TB solely based on Truenat assay results, without any additional diagnostic tests being conducted.”
Garmaa, G., Nagy, R., Kói, T., To, U. N. D., Gergő, D., Kleiner, D., Csupor, D., Hegyi, P., & Kökény, G. (2024) · BMC Nephrology · doi:10.1186/s12882-024-03702-y · Cited by 14
“The Quality Assessment of Diagnostic Accuracy Studies (QUA-DAS-2) [23] guidelines were used to evaluate study quality and assess the following variables: patient selection, index test, reference standard, and flow and timing (see Supplementary Material).”
MethodDyer, C., Jin, F., Hillman, R. J., Nyitray, A. G., Roberts, J. M., Law, C. L. H., Grulich, A. E., & Poynten, I. M. (2024) · International Journal of Cancer · doi:10.1002/ijc.35133 · Cited by 14
“28 Any discrepancies were discussed, and consensus was reached.”
Dadam, M. N., Hien, L. T., Makram, E. M., Lam, V. S., Morad, A., Khalil, N., Tran, L. T., Makram, A. M., & Huy, N. T. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305895 · Cited by 15
Shi, L., Zhao, J., Wei, Z., Wu, H., & Sheng, M. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1381217 · Cited by 14
“The purpose of QUADAS-2 is to evaluate the quality of primary diagnostic studies, which includes 4 key domains: patient selection, index test, reference standard, and fl ow and timing (15).”
BackgroundWan, Q.-C., Bai, L., Wang, Z., & Ji, B. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.09.026 · Cited by 14
Rey, I., Lago, V., Arnáez, M., Bizzarri, N., Agustí, N., Nero, C., Díaz‐Feijoó, B., Padilla-Iserte, P., & Domingo, S. (2024) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2024-005970 · Cited by 14
Toe-brachial index and toe systolic blood pressure for the diagnosis of peripheral arterial disease
Tehan, P. E., Mills, J. L., Leask, S., Oldmeadow, C. J., Peterson, B. J., Sebastian, M. G., & Chuter, V. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013783.pub2 · Cited by 23
Hajikarimloo, B., Tos, S. M., Alvani, M. S., Rafiei, M. A., Akbarzadeh, D., Eftekhar, M. S., Akhlaghpasand, M., & Habibi, M. A. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.10.089 · Cited by 14
Abbaspour, E., Mansoori, B., Karimzadhagh, S., Chalian, M., Pouramini, A., Sheida, F., Daskareh, M., & Haseli, S. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04668-z · Cited by 14
“E.A. and S.K. independently assessed the included articles using the modified Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [26].”
Zanjirband, M., Nasr‐Esfahani, M. H., Curtin, N. J., Drew, Y., Saha, S. K., Adibi, P., & Lunec, J. (2024) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.70312 · Cited by 14
Ahmadzadeh, A. M., Lomer, N. B., Ashoobi, M. A., Bathla, G., & Sotoudeh, H. (2024) · Clinical Imaging · doi:10.1016/j.clinimag.2024.110386 · Cited by 14
O’Donald, F., & Calia, C. (2025) · Health Science Reports · doi:10.1002/hsr2.70289 · Cited by 16
“The Quality Assessment of Diagnostic Accuracy Studies Version 2 (QUADAS ‐ 2), developed by Whiting et al. [54], was used as a tool for evaluating the potential risk of bias and applicability of studies included in this review.”
Various biases in systematic review and meta-analysis and their assessment
Nair, A. S., & Borkar, N. B. (2025) · Indian Journal of Anaesthesia · doi:10.4103/ija.ija_1212_24 · Cited by 14
“[14] The four domains of QUADAS-2 are patient selection, index test, reference standard, flow, and timing.”
Gupta, A., Anis, S., & de Pablo, P. (2025) · Rheumatology · doi:10.1093/rheumatology/keaf045 · Cited by 14
Giaccone, P., D’Antoni, F., Russo, F., Ambrosio, L., Papalia, G. F., d’Angelis, O., Vadalà, G., Comelli, A., Vollero, L., Merone, M., et al. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-08356-x · Cited by 14
Wang, S.-T., Gu, H.-Y., Huang, Z.-C., Li, C., Liu, W.-N., & Li, R. (2025) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2025.105029 · Cited by 14
Ullah, N., Muccio, M., Magnasco, L., Sepulcri, C., Giacobbe, D. R., Vena, A., Bassetti, M., & Mikulska, M. (2025) · Journal of Fungi · doi:10.3390/jof11020149 · Cited by 18
Eisinger, G. J., Hosler, Q., Crouser, E. D., & Herman, D. D. (2025) · Journal of the American College of Emergency Physicians Open · doi:10.1016/j.acepjo.2025.100073 · Cited by 18
Texture Analysis in Musculoskeletal Ultrasonography: A Systematic Review
Jan, Y., Hung, I. Y., & Cheung, W. C. (2025) · Diagnostics · doi:10.3390/diagnostics15050524 · Cited by 15
Javid, R. N., Moradi, M., Mahalleh, M., Najafi‐Vosough, R., Arzhangzadeh, A., Khalique, O. K., Mojibian, H. R., Kuno, T., Mohsen, A., Alam, M., et al. (2025) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2025.02.004 · Cited by 14
Cutaneous manifestations of Fabry disease: A systematic review
Al‐Chaer, R. N., Folkmann, M., Mårtensson, N. L., Feldt‐Rasmussen, U., & Mogensen, M. (2025) · The Journal of Dermatology · doi:10.1111/1346-8138.17690 · Cited by 14
Ultrasound accuracy in acute diverticulitis: A systematic review and Meta-analysis
Shokoohi, H., Peksa, G. D., Hutchison, A., Jalbout, N. A., Montoya, K., Westrick, J. C., Goldsmith, A. J., Nazerian, P., & Gottlieb, M. A. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.03.002 · Cited by 14
Jiang, Y., Yan, H., Cui, J., Yang, K., & An, Y. (2025) · Helicobacter · doi:10.1111/hel.70026 · Cited by 14
Lee, C.-F., Lin, J., Huang, Y.-L., Chen, S.-T., Chou, C., Chen, D.-R., & Wu, W.-P. (2025) · Cancer Imaging · doi:10.1186/s40644-025-00863-3 · Cited by 14
“Finally, study quality assessment was performed by the same two readers according to the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS)- AI [35, 36].”
Diagnosis of Oral Cancer With Deep Learning. A Comparative Test Accuracy Systematic Review
Nieri, M., Serni, L., Clauser, T., Paoletti, C., & Franchi, L. (2025) · Oral Diseases · doi:10.1111/odi.15330 · Cited by 14
“QUADAS-C is an extension of QUADAS-2 (Whiting et al. 2011) specifically designed for evaluating the risk of bias in comparative diagnostic test accuracy studies.”
Augmented intelligence in oral and maxillofacial radiology: a systematic review
Math, S. Y., Ameli, N., Stefani, C. M., Kung, J. Y. C., Punithakumar, K., Amin, M. S., & Pachêco‐Pereira, C. (2025) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2025.03.015 · Cited by 21
Zhong, R., Wu, X., Chen, J., & Fang, Y. (2025) · Journal of Medical Internet Research · doi:10.2196/72229 · Cited by 20
Dedhia, M., & Germano, I. M. (2025) · Cancers · doi:10.3390/cancers17091582 · Cited by 14
Ju, C., Yao, L., Yoon, S.-Y., Lenchik, L., Johnston, A., Derry, L. T., Hom, J., Svec, D., Chaudhari, A. S., & Boutin, R. D. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.25.32781 · Cited by 15
Ebner, D. W., Johnson, H. A., Estes, C., Johnson, W. K., Khan, R. S., Thompson, G., Kong, J., Camardo, M., Dore, M. M., Vahdat, V., et al. (2025) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2025.107654 · Cited by 14
Bechyna, S., & Baltzer, P. (2025) · Radiology · doi:10.1148/radiol.241919 · Cited by 14
Lomer, N. B., Abdi, S., Ashoobi, M. A., Ahmadzadeh, A. M., Ghasemi, A., & Torigian, D. A. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.05.049 · Cited by 14
Antolí, A., Rodriguez-Lozano, F. J., Cañas, J. J., Vacas, J., Cuadrado, F., Sánchez-Raya, A., Dueñas, C. P., & Gámez, J. C. V. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1558621 · Cited by 16
Luo, M., Duan, Z., Li, Y., Wang, Y., Chen, L., Gao, J., Wu, M., Sun, Y., Chen, L., & Feng, X. (2025) · Age and Ageing · doi:10.1093/ageing/afaf181 · Cited by 17
Ju, J., Qu, Z., Qing, H., Ding, Y., & Peng, L. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-08842-2 · Cited by 16
“This tool comprises four key domains: patient selection, index test, reference standard, and flow and timing [18, 19].”
Aghayan, A. H., Bayani, A., Abbaspour, M., Gharehchahi, F., & Samarkhazan, H. S. (2025) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.104884 · Cited by 14
Acosta-Reyes, J. L., Garrido, D. P. R., Acosta, T., Aschner, P. J., Fraga, C. A., Vázquez‐Fernández, A., Tuomilehto, J. O., & Gabriel, R. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112480 · Cited by 15
Hein, I. M., Daams, J. G., Troost, P. W., Lindeboom, R., & Lindauer, R. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011099.pub2 · Cited by 14
MacInnis, M. J., Lohse, K. R., Strong, J. K., & Koehle, M. S. (2013) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-092921 · Cited by 15
Magnetic resonance imaging (MRI) for diagnosis of acute appendicitis
D’Souza, N., Thaventhiran, A., Beable, R., Higginson, A., & Rud, B. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012028 · Cited by 14
Diagnostic Value of Contrast‐Enhanced Sonography for Differentiation of Breast Lesions
Ma, X., Liu, R., Zhu, C., Zhang, J., & Ling, W. (2016) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.10005 · Cited by 14
Wang, Y., Zhao, M., Ma, Y., & Yang, B. (2016) · Journal of Cancer Research and Therapeutics · doi:10.4103/0973-1482.200742 · Cited by 14
Mackenzie, C. F., Pasley, J. D., Garofalo, E. M., Shackelford, S. A., Chen, H., Longinaker, N., Granite, G., Pugh, K., Hagegeorge, G., & Tisherman, S. A. (2017) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000001467 · Cited by 14
Chen, Z., Zheng, Y., Ji, G., Liu, X., Li, P., Cai, L., Yulin, G., & Yang, J. (2017) · Oncotarget · doi:10.18632/oncotarget.20316 · Cited by 16
Liao, J., Chen, Y., Cai, Y., Zhan, N., Sylvia, S., Hanson, K., Wang, H., Wasserheit, J. N., Gong, W., Zhou, Z., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020943 · Cited by 14
Elkaryoni, A., Nanda, N. C., Baweja, P. S., Arisha, M. J., Zamir, H., Elgebaly, A. S., Altibi, A. M. A., & Sharma, R. (2018) · Echocardiography · doi:10.1111/echo.14147 · Cited by 14
Tests to detect and inform the diagnosis of root caries
Fee, P. A., Macey, R., Walsh, T., Clarkson, J., & Ricketts, D. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013806 · Cited by 19
Faes, L., Bodmer, N. S., Locher, S., Keane, P. A., Balaskas, K., Bachmann, L. M., Schlingemann, R. O., & Schmid, M. (2019) · Eye · doi:10.1038/s41433-019-0421-3 · Cited by 14
Rational use of diagnostic tests for clinical decision making
Buehler, A. M., Ascef, B. D. O., de Oliveira, H. A., Ferri, C. P., & Fernandes, J. G. (2019) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.65.3.452 · Cited by 18
Zuo, W., Yang, M., Chen, Y., Xie, A., Chen, L., & Ma, G. (2019) · BioMed Research International · doi:10.1155/2019/5828931 · Cited by 14
“3 (Nordic Cochrane Centre, The Cochrane Collaboration, 2014, Copenhagen, Denmark) with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [13] by two investigators.”
InfluentialLockwood, P., & Pittock, L. J. (2019) · Radiography · doi:10.1016/j.radi.2019.04.013 · Cited by 15
Wu, Y., Jing, J., Wang, J., Xu, B., Du, M., & Chen, M. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00585 · Cited by 14
Leone, A. M., Campo, G. C., Gallo, F., Pavasini, R., Basile, E., D’Amario, D., Tebaldi, M., Biscaglia, S., Maietti, E., Trani, C., et al. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.07.035 · Cited by 14
Yan, L., & Hu, Z.-D. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.06.72 · Cited by 17
Arévalo-Rodríguez, I., Moreno-Nuñez, P., Nußbaumer-Streit, B., Steingart, K. R., Peña, L. D. M. G., Buitrago‐García, D., Kaunelis, D., Emparanza, J. I., Alonso‐Coello, P., Tricco, A. C., et al. (2019) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2019.09.004 · Cited by 14
Persistence of Crystals in Stored Synovial Fluid Samples
Pastor, S., Bernal, J. A., Caño, R., Gómez, S., Borrás, F., & Andrés, M. (2020) · The Journal of Rheumatology · doi:10.3899/jrheum.190468 · Cited by 14
Kim, T., Woo, S., Halpenny, D. F., Kim, Y. J., Yoon, S. H., & Suh, C. H. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108978 · Cited by 17
Wu, J., Wang, Y., & Wang, Z. (2020) · Medical Ultrasonography · doi:10.11152/mu-2659 · Cited by 14
Sun, W. Y. L., Dang, J. T., Modasi, A., Nasralla, A., Switzer, N. J., Birch, D. W., Turner, S. R., & Karmali, S. (2020) · General Thoracic and Cardiovascular Surgery · doi:10.1007/s11748-020-01400-8 · Cited by 14
Diagnostic performance of coagulation indices for direct oral anticoagulant concentration
Zhang, H., Liu, Z., Mu, G., Wang, Z., Zhou, S., Xie, Q., Ma, L., Wang, Z., Hu, K., Gong, Y., et al. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.07.031 · Cited by 15
Chen, B., Zhang, R. N., Fan, X., Wang, J., Xu, C., An, B., Wang, Q., Wang, J., Leung, E. L., Sui, X., et al. (2020) · Journal of Cancer · doi:10.7150/jca.46358 · Cited by 14
Translating Laboratory Tests into Clinical Practice: A Conceptual Framework
Nagler, M. (2020) · Hämostaseologie · doi:10.1055/a-1227-8008 · Cited by 15
Xie, T., Liu, Y., Meng, R.-C., Liu, X., Fang, K., Deng, S., Fan, S.-J., Chen, C., Lin, Q.-R., He, Z., et al. (2020) · BioMed Research International · doi:10.1155/2020/2892734 · Cited by 14
Krastman, P., Mathijssen, N. M. C., Bierma‐Zeinstra, S., Kraan, G. A., & Runhaar, J. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-037810 · Cited by 14
Jiang, X., Hui, F., Qin, X., Wu, Y., Liu, H., Gao, J., Li, X., Xu, Y., & Zhang, Y. (2020) · Journal of Cancer · doi:10.7150/jca.49970 · Cited by 16
Guo, L.-Y., Schneider, P., & Harrison, W. (2020) · Language Speech and Hearing Services in Schools · doi:10.1044/2020_lshss-20-00043 · Cited by 18
Subclassification of BI-RADS 4 Magnetic Resonance Lesions: A Systematic Review and Meta-Analysis
Li, J., Zheng, H., Cai, W., Wang, Y., Zhang, H., & Liao, M. (2020) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001108 · Cited by 14
Folger, L. V., Panchal, P., Eglovitch, M., Whelan, R., & Lee, A. C. (2020) · BMJ Global Health · doi:10.1136/bmjgh-2020-002976 · Cited by 18
Martin-Key, N. A., Schei, T. S., Barker, E., Spadaro, B., Funnell, E. L., Benáček, J., Tomasik, J., & Bahn, S. (2020) · JMIR Research Protocols · doi:10.2196/25382 · Cited by 14
Tranoulis, A., Georgiou, D., Yap, J. K. W., Montalto, S. A., Twigg, J., Elattar, A., Singh, K., Balega, J., & Kehoe, S. T. (2020) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2020.12.001 · Cited by 14
Huang, J., Liu, M., He, W., Liu, F., Cheng, J., & Wang, H. (2021) · BMC Neurology · doi:10.1186/s12883-021-02060-8 · Cited by 14
Leigheb, M., Tricca, S., Percivale, I., Licandro, D., Paladini, A., Barini, M., Guzzardi, G., Grassi, F. A., Stecco, A., & Carriero, A. (2021) · Brain Sciences · doi:10.3390/brainsci11020173 · Cited by 14
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.