QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 6,701–6,800 of 14,770
van Vliet, J. T., Majani, N. G., Chillo, P., & Slieker, M. G. (2023) · Children · doi:10.3390/children11010047 · Cited by 18
Luo, X., Zheng, R., Zhang, J., He, J., Luo, W., Jiang, Z. L., & Li, Q. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1329801 · Cited by 20
A meta-analysis for the diagnostic accuracy of SelectMDx in prostate cancer
Wu, H., Wu, Y., He, P., Liang, J., Xu, X., & Ji, C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0285745 · Cited by 15
Macêdo, J. V. D. L., da Silva, A. G., Oliveira, M. D. L., & Andrade, C. A. S. (2024) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2024.116227 · Cited by 15
Current evidence for lung ultrasound elastography in the field of pneumology: a systematic review
Vargas-Ursúa, F., Hernández, C. R., Pazos-Area, L. A., Fernández-Granda, I., Rodríguez-Otero, I., Gómez-Corredoira, E., Pintos-Louro, M., & Fernández‐Villar, A. (2024) · ERJ Open Research · doi:10.1183/23120541.00081-2024 · Cited by 15
“The studies included for every respiratory pathology subtype all presented biases, especially in relation to patient selection (as individually presented in supplementary tables 1S – 3S according to the results from the QUADAS-2 tool [12]).”
InfluentialYoung, G. C., & Erdődi, L. A. (2024) · Psychological Injury and Law · doi:10.1007/s12207-024-09504-9 · Cited by 15
Vacca, S., Scicolone, R., Gupta, A. K., Wasserman, B. A., Song, J. H., Nardi, V., Yang, Q., Benson, J. C., Lanzino, G. S., Paraskevas, K. I., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111547 · Cited by 16
Noguchi, S., Katsurada, M., Yatera, K., Nakagawa, N., Xu, D., Fukuda, Y., Shindo, Y., Senda, K., Tsukada, H., Miki, M., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-63618-3 · Cited by 16
The role of microRNAs as super-early biomarkers in acute ischemic stroke: A systematic review
Loggini, A., Hornik, J., & Hornik, A. (2024) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2024.108416 · Cited by 16
Luo, Y., Huang, Y.-T., Chiu, V. J.-Y., Chang, Y.-W., & Horng, Y.-S. (2024) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2024.06.026 · Cited by 15
Kim, M. N., An, J., Kim, E. H., Kim, H. Y., Lee, H. A., Yu, J. H., Jin, Y., Chon, Y. E., Kim, S. U., Jun, D. W., et al. (2024) · Clinical and Molecular Hepatology · doi:10.3350/cmh.2024.0371 · Cited by 17
Diagnostic Accuracy of Artificial Intelligence in Endoscopy: Umbrella Review
Zha, B., Cai, A., & Wang, G. (2024) · JMIR Medical Informatics · doi:10.2196/56361 · Cited by 20
“In 2011, researchers developed QUADAS-2 for better evaluation [38].”
BackgroundDiagnostic accuracy of portable sleep monitors in pediatric sleep apnea: A systematic review
Landry, V., Semsar‐Kazerooni, K., Chen, T., Gurberg, J., Nguyen, L. H. P., & Constantin, E. (2024) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2024.101991 · Cited by 15
Hirabayashi, E., Mercado, G., Hull, B., Soin, S., Koshy-Chenthittayil, S., Raman, S., Huang, T., Keerthisinghe, C., Feliciano, S., Dongo, A., et al. (2024) · JBI Evidence Synthesis · doi:10.11124/jbies-23-00291 · Cited by 18
Jie, P., Fan, M., Zhang, H., Wang, O., Lv, J., Liu, Y., Zhang, C., Liu, Y., & Zhao, J. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1398963 · Cited by 15
Carroll, J., Manzano, C. L., Tomlinson, E., Sadek, A., Cooper, C., Jones, H. E., Rowsell, L., Knight, J., Mumford, A. D., Palmer, R., et al. (2024) · Health Technology Assessment · doi:10.3310/pwcb4016 · Cited by 17
Self-citationUsing heart rate variability to predict neurological outcomes in preterm infants: a scoping review
Smolkova, M., Sekar, S., Kim, S. H., Sunwoo, J., & El‐Dib, M. (2024) · Pediatric Research · doi:10.1038/s41390-024-03606-5 · Cited by 17
“36 HRV metrics were further classi fi ed based on Chiera et al. 21 as time domain, frequency domain, or non-linear with HRC also being a separate category.”
MethodLlewellyn, A., Phung, T. H., Soares, M. O., Shepherd, L., Glynn, D., Harden, M., Walker, R., Duarte, A., & Dias, S. (2024) · Health Technology Assessment · doi:10.3310/plfg4210 · Cited by 18
Zou, Z., Chen, B., Xiao, D., Tang, F., & Li, X. (2024) · Journal of Medical Internet Research · doi:10.2196/55986 · Cited by 19
Muhib, M., Abidi, S. L. F., Ahmed, U., Afzal, A., Farooqui, A., Jamil, O. B. K., Ahmed, S., & Agha, H. (2024) · SAGE Open Medicine · doi:10.1177/20503121241293496 · Cited by 16
de Mesquita, Y. L. L., Marques, I. R., Calvi, I. P., Cruz, S. A., Godoi, A., Lapenda, I., de Moraes‐Souza, R., Relvas, J. H., Vilbert, M., Nehal, K. S., et al. (2024) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.20383 · Cited by 19
“18 Each of the four domains and three applicability concerns were rated as low, high or unclear risk of bias.”
Taheri, O., Samain, J., Mauny, F., Puyraveau, M., Desmettre, T., & Marx, T. (2024) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001205 · Cited by 15
Sharifi, G., Hajibeygi, R., Zamani, S. A. M., Easa, A. M., Bahrami, A., Eshraghi, R., Moafi, M., Ebrahimi, M. J., Fathi, M., Mirjafari, A., et al. (2024) · Emergency Radiology · doi:10.1007/s10140-024-02300-7 · Cited by 18
“[32] This scoring system assesses the reliability and generalizability of data particularly on diagnostic accuracy studies based on a questionnaire that investigates potential bias with respect to 4 domains of (1) patient selection, (2) index test(s), (3) reference standard and (4) flow and timing.”
Kaul, R. D., Sacks, P., Thiel, C., Rimmer, J., Kalish, L. H., Campbell, R. G., Sacks, R., Ieva, A. D., & Harvey, R. J. (2024) · American Journal of Rhinology and Allergy · doi:10.1177/19458924241304082 · Cited by 16
“15,16 Level of evidence: The level of evidence for each study was recorded as per the Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence table.”
Yang, F., Zhu, L., Cao, B., Zeng, L., Yuan, Z., Tian, Y., Li, Y., & Chen, X. (2024) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2024.105419 · Cited by 17
Wejnaruemarn, S., Susantitaphong, P., Komolmit, P., Treeprasertsuk, S., & Thanapirom, K. (2025) · World Journal of Gastroenterology · doi:10.3748/wjg.v31.i6.99506 · Cited by 19
“The quality of selected studies was assessed by two independent reviewers (Wejnaruemarn S and Thanapirom K) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2)[42].”
Gareeballah, A., Gameraddin, M. B., Alshoabi, S. A., Alsaedi, A. F., Elzaki, M. M., Alsharif, W. M., Daoud, I. M., Aldahery, S. T., Alelyani, M., AbdElrahim, E., et al. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2024.1474930 · Cited by 15
Tavanaei, R., Akhlaghpasand, M., Alikhani, A., Hajikarimloo, B., Ansari, A., Yong, R. L. M., & Margetis, K. D. (2025) · Neurosurgical Review · doi:10.1007/s10143-025-03236-3 · Cited by 17
Palumbo, A. M., Jacob, C. M., Khademioore, S., Sakib, M. N., Yoshida‐Montezuma, Y., Christodoulakis, N., Yassa, P., Vanama, M. S., Gamra, S., Ho, P., et al. (2025) · Obesity Reviews · doi:10.1111/obr.13894 · Cited by 21
“Risk of bias and concerns regarding applicability were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool, 26 only for studies included in the validity and reliability extraction phase.”
Stehlik, P., Withers, C., Bourke, R., Barnett, A. G., Brandenburg, C., Noble, C., Bannach‐Brown, A., Keijzers, G., Scott, I. A., Glasziou, P., et al. (2025) · The Medical Journal of Australia · doi:10.5694/mja2.52611 · Cited by 17
Ebell, M. H., Rahmatullah, I., Hulme, C., Buhr, M., Kotnik, J. H., Geyer, R. E., Thompson, M., & Lutz, B. R. (2025) · BMJ Open · doi:10.1136/bmjopen-2022-067574 · Cited by 19
Genetic Biomarkers for Periodontal Diseases: A Systematic Review
Dommisch, H., Hoedke, D., Lu, E. M., Schäefer, A. S., Richter, G. M., Kang, J. X., & Nibali, L. (2025) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.14149 · Cited by 21
“The quality of the included studies was assessed using the critical review checklist of the revised Quality Assessment of Diagnostic Studies (QUADAS-2) (Whiting et al. 2011).”
Diagnostic Utility of Biomarkers in Anaphylaxis: A Systematic Review and Meta-Analysis
Khalaf, R., Prosty, C. J., Davalan, W., Abrams, E. M., Kaouache, M., & Ben‐Shoshan, M. (2025) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2025.04.008 · Cited by 24
Shahbazi, S., Esmaeili, S., Kavousinejad, S., Younessian, F., & Behnaz, M. (2025) · International Orthodontics · doi:10.1016/j.ortho.2025.101010 · Cited by 15
Salimi, M., Houshi, S., Gholamrezanezhad, A., Vadipour, P., & Seifi, S. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110494 · Cited by 16
Castro-Luna, D. I., Porras-Hernández, J. D., Flores-García, J. A., Dies-Suárez, P., Servin-Martínez, M. F., & Pierdant-Pérez, M. (2025) · Pediatric Radiology · doi:10.1007/s00247-025-06261-y · Cited by 16
“Methodological quality was evaluated using the QUADAS-2 tool [15] by two independent reviewers.”
Alexander, C. E., Warren, H. R., Light, A., Agarwal, R., Asif, A., Chow, B. J., Clement, K. D., Chan, V. W., Zimmermann, E. F., Khadhouri, S., et al. (2025) · European Urology Focus · doi:10.1016/j.euf.2025.04.026 · Cited by 15
Lomer, N. B., Ghasemi, A., Ahmadzadeh, A. M., & Torigian, D. A. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04982-0 · Cited by 15
“Two independent reviewers assessed the quality of each study using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and the METhodological Radiom-ICs Score (METRICS) tools [19, 20].”
Bridging Genomics to Cardiology Clinical Practice
Hosseini, K., Anaraki, N., Dastjerdi, P., Kazemian, S., Hasanzad, M., Alkhouli, M. A., Alam, M., Nasir, K., Rana, J. S., & Bhatt, A. B. (2025) · JACC Advances · doi:10.1016/j.jacadv.2025.101803 · Cited by 25
Translating radiomics into clinical practice: A step-by-step guide to study design and evaluation
Chen, M., Linton‐Reid, K., Aboagye, E. O., & Copley, S. J. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.107053 · Cited by 19
Singh, S., Singha, B., & Kumar, S. (2024) · The Journal of Forensic Odonto-Stomatology · doi:10.5281/zenodo.11088512 · Cited by 28
“15 In the present systematic review, an e ff ort has been made to analyse various AI tools for prompt identification involving a ge and sex in maxillofacial radiographs ( Table 2 ) .”
Lai, S. W., Roberts, D. J., Rabi, D. M., & Winston, K. Y. (2015) · Systematic Reviews · doi:10.1186/s13643-015-0109-0 · Cited by 18
How to Critically Appraise the Clinical Literature
Cronin, P., Rawson, J. V., Heilbrun, M. E., Lee, J. M., Kelly, A. M., Sanelli, P. C., Bresnahan, B. W., & Paladin, A. M. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.05.004 · Cited by 15
Lü, W., Zheng, J., Pan, X., Zhang, M., Zhu, T.-Y., Li, B., & Sun, L. (2015) · PubMed Central · doi:10.3978/j.issn.2072-1439.2015.01.27 · Cited by 15
Kapaya, H., Jacques, R., Rahaim, N., & Anumba, D. O. C. (2016) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2016.1156670 · Cited by 16
Alternative Colposcopy Techniques
Hermens, M., Ebisch, R. M. F., Galaal, K. A., & Bekkers, R. L. M. (2016) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000001613 · Cited by 15
Procalcitonin, C-reactive protein, and presepsin for the diagnosis of sepsis in adults and children
Onyenekwu, C. P., Okwundu, C. I., & Ochodo, E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012627 · Cited by 20
A meta-analysis: The diagnostic values of long non-coding RNA as a biomarker for gastric cancer
Hu, Q., Zhao, Z., Li, S., Li, L., & Li, G. (2017) · Molecular and Clinical Oncology · doi:10.3892/mco.2017.1227 · Cited by 15
Syer, T., Godley, K. C., Cameron, D., & Malcolm, P. N. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1400-4 · Cited by 15
Michelessi, M., Lucenteforte, E., Miele, A., Oddone, F., Crescioli, G., Fameli, V., Korevaar, D. A., & Virgili, G. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189716 · Cited by 19
Low, G. K. K., Looi, S. Y., Yong, M.-H., & Sharma, D. (2018) · Journal of Vector Borne Diseases · doi:10.4103/0972-9062.242568 · Cited by 15
Sano, H., Tomita, K., Sano, A., 佐伯, 翔., Nishikawa, Y., Nishiyama, O., Iwanaga, T., & Tohda, Y. (2018) · Allergology International · doi:10.1016/j.alit.2018.08.013 · Cited by 14
Minaker, S. A., Mason, R. H., Bamakrid, M., Lee, Y., & Muni, R. H. (2019) · Journal of VitreoRetinal Diseases · doi:10.1177/2474126419880391 · Cited by 15
Hu, X., Peng, Q., Zhu, J., Shen, Y., Lin, K., Shen, Y., & Zhu, Y. (2019) · Gene · doi:10.1016/j.gene.2019.144225 · Cited by 17
Lao, Y., Jia, B., Yan, P., Pan, M., Xu, H., Li, J., Luo, W. P., Li, X., Han, J., Yan, P., et al. (2019) · Medicine · doi:10.1097/md.0000000000018324 · Cited by 16
Evolutions and upcoming on Zika virus diagnosis through an outbreak: A systematic review
Jorge, F. A., Thomazella, M. V., Moreira, D. D. C., Lopes, L. D. G., Teixeira, J. J. V., & Bertolini, D. A. (2020) · Reviews in Medical Virology · doi:10.1002/rmv.2105 · Cited by 17
Liu, X., McNally, T. W., Beese, S. E., Downie, L. E., Solebo, A. L., Faes, L., Husain, S. A., Keane, P. A., Moore, D., & Denniston, A. K. (2020) · Ocular Immunology and Inflammation · doi:10.1080/09273948.2019.1709650 · Cited by 15
Histographic analysis of oedema and fat in inflamed bone marrow based on quantitative MRI
Bray, T., Sakai, N. S., Dudek, A., Fisher, C., Rajesparan, K., Lopes, A., Ciurtin, C., Sen, D., Bainbridge, A. P., & Hall-Craggs, M. A. (2020) · European Radiology · doi:10.1007/s00330-020-06785-x · Cited by 15
Higginbotham, O., O’Neill, A., Barry, L. A., Leahy, A. M., Robinson, K., O’Connor, M., & Galvin, R. (2020) · HRB Open Research · doi:10.12688/hrbopenres.13042.1 · Cited by 16
Accuracy of Ultrasonography in Breast Implant Rupture Diagnosis: Systematic Review and Meta-Analysis
Macedo, A. C. L., Carvalho, G., Uggioni, M. L. R., Bavaresco, D. V., Simon, C. S., Cruz, M., Silva, F., & da Rosa, M. I. (2021) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000008408 · Cited by 15
The effectiveness of different teaching methods on medical or nursing students
Yun, B., Su, Q., Cai, Y., Chen, L., Qu, C., & Han, L. (2020) · Medicine · doi:10.1097/md.0000000000021668 · Cited by 15
“Two reviewers (Y.B. and C. YT.) will independently assess the risk of bias for each study as low, moderate, or high using the Quality Assessment of Diagnostic Accuracy Studies.”
Bosco, A., Caffò, A. O., Spano, G., & Lopez, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815854-8.00025-2 · Cited by 16
Diagnostic Accuracy of T-SPOT.TB Assay for Tuberculous Meningitis: An Updated Meta-Analysis
Luo, Y., Xue, Y., Guo, X., Lin, Q., Mao, L., Tang, G., Song, H., Wang, F., & Sun, Z. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00866 · Cited by 17
Cho, S. J., Kim, J. H., Baik, S. H., Sunwoo, L., Bae, Y. J., & Choi, B. S. (2020) · Neuroradiology · doi:10.1007/s00234-020-02538-1 · Cited by 15
Cardiac Imaging to Assess Left Ventricular Systolic Function in Atrial Fibrillation
Bunting, K. V., O'Connor, K., Steeds, R. P., & Kotecha, D. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.10.012 · Cited by 15
Wu, J., Sun, Y., Wang, Y., Ge, L., Jin, Y. H., & Wang, Z. (2021) · Medical Ultrasonography · doi:10.11152/mu-2971 · Cited by 15
Kim, P. H., Lee, D. H., Suh, C. H., Kim, M., Shim, W. H., & Kim, S. J. (2021) · European Radiology · doi:10.1007/s00330-020-07627-6 · Cited by 15
Andrade, E. S. N., Brandão, J. G., da Silva, J. S., Kurizky, P. S., Rosa, P. S., de Araújo, W. N., & Gomes, C. M. (2021) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2021.115325 · Cited by 17
Gill, H. S., & Hiller, J. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00417-0 · Cited by 18
Prognostic Significance of CD30 in Transformed Mycosis Fungoides
Travaglino, A., Russo, D., Varricchio, S., Pignatiello, S., Baldo, A., Picardi, M., Pane, F., & Mascolo, M. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa261 · Cited by 15
Åneman, A., Wilander, P., Zoerner, F., Lipcsey, M., & Chew, M. S. (2021) · Shock · doi:10.1097/shk.0000000000001762 · Cited by 18
Yokoyama, K., Tsuchiya, J., & Tateishi, U. (2021) · Diagnostics · doi:10.3390/diagnostics11040706 · Cited by 15
Luo, D., Liu, F., Dai, W., Zhang, J., Shao, Q., Tao, W., Xiao, R., Feng, X., & Qian, K. (2021) · Pediatric Anesthesia · doi:10.1111/pan.14195 · Cited by 15
Assessments of Physicians’ Electrocardiogram Interpretation Skill: A Systematic Review
Cook, D. A., Oh, S.-Y., & Pusic, M. V. (2022) · Academic Medicine · doi:10.1097/acm.0000000000004140 · Cited by 15
Abdalla‐Aslan, R., Shilo, D., Nadler, C., Eran, A., & Rachmiel, A. (2021) · Journal of Oral Rehabilitation · doi:10.1111/joor.13179 · Cited by 17
Vali, Y., Leeflang, M., & Bossuyt, P. M. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01744-z · Cited by 17
Self-citationZhao, G., Murphy, K. E., Berger, H. M., Shah, B. R., Halperin, I. J., Barrett, J. F. R., & Melamed, N. (2021) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2021.1956896 · Cited by 16
Komolafe, T. E., Cao, Y., Nguchu, B. A., Monkam, P., Olaniyi, E. O., Sun, H., Zheng, J., & Yang, X. (2021) · Academic Radiology · doi:10.1016/j.acra.2021.08.008 · Cited by 15
Aly, M. M., Al-Shoaibi, A. M., Ali, S. A., Alzahrani, A., & Eldawoody, H. A. F. (2021) · European Spine Journal · doi:10.1007/s00586-021-06987-x · Cited by 15
Diagnostic accuracy of lung ultrasonography in childhood pneumonia: a meta-analysis
Lu, X., Jin, Y., Li, Y., Weng, L., & Li, H. (2021) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000883 · Cited by 15
Serum CA-125 for the diagnosis of pulmonary tuberculosis: a systematic review and meta-analysis
Zhao, P., Yu, Q., Zhang, A., He, F., Xu, S., & Chen, L. (2021) · BMC Infectious Diseases · doi:10.1186/s12879-021-06772-7 · Cited by 15
Inzani, F. S., Santoro, A., Travaglino, A., D’Alessandris, N., Raffone, A., Straccia, P., Angelico, G., Arciuolo, D., Scaglione, G., Valente, M., et al. (2021) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-021-06305-2 · Cited by 15
Wang, L., Li, J., Xiong, X., Hao, T., Zhang, C., Gao, Z., Zhong, L., & Zhao, Y. (2021) · Scientific Reports · doi:10.1038/s41598-021-02906-8 · Cited by 16
Li, W., Shang, W., Lu, F., Sun, Y., Tian, J. Q., Wu, Y., & Dong, A. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2021.792120 · Cited by 18
Ughi, N., Padoan, R., Crotti, C., Sciascia, S., Carrara, G., Zanetti, A., Rozza, D., Monti, S. M., Camellino, D., Muratore, F., et al. (2022) · Reumatismo · doi:10.4081/reumatismo.2021.1470 · Cited by 16
van Liere, E. L. S. A., de Boer, N. K. H., Dekker, E., van Leerdam, M. E., de Meij, T. G. J., & Ramsoekh, D. (2022) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.16824 · Cited by 15
Kalot, M. A., Husainat, N. M., Abughanimeh, O. K. M., Diab, O. A., Alayli, A. E., Tayiem, S., Madoukh, B., Dimassi, A. B., Qureini, A., Ameer, B., et al. (2022) · Blood Advances · doi:10.1182/bloodadvances.2021005431 · Cited by 15
Lee, S. W., & Kim, S.-J. (2022) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000004110 · Cited by 18
Wu, X., Shi, Y., Wang, X., Yu, X., & Yang, M. (2022) · The Clinical Respiratory Journal · doi:10.1111/crj.13485 · Cited by 15
Yue, X., Zhong, L., Wang, Y., Zhang, C., Chen, X., Wang, S., Hu, J., Hu, J., Wang, C., & Liu, X. (2022) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2022.02.001 · Cited by 15
Sharma, G., Sharma, A., Krishna, M., Ahluwalia, P., & Gautam, G. (2022) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2022.03.001 · Cited by 15
Rath, C. P., Rao, S. C., Suryawanshi, P. B., Desai, S., Chetan, C., Patil, K. H., & Patole, S. (2022) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.15236 · Cited by 15
Momeni-Moghaddam, M., Hashemi, C., Fathi, A., & Khamesipour, F. (2022) · Beni-Suef University Journal of Basic and Applied Sciences · doi:10.1186/s43088-022-00243-x · Cited by 18
Circulating Non-coding RNAs as Potential Biomarkers for Ischemic Stroke: A Systematic Review
Zhao, J., Wang, Q., Zhu, R., & Yang, J. (2022) · Journal of Molecular Neuroscience · doi:10.1007/s12031-022-01991-2 · Cited by 15
Pei, Y., Tang, X., Zhang, E., Lu, K., Xia, B., Zhang, J., Huang, Y., Zhang, H., & Dong, L. (2022) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-022-01979-y · Cited by 22
Sentinel node biopsy for diagnosis of lymph node involvement in endometrial cancer
Nagar, H., Goodall, R. J., Lyons, T. J., Schmidt‐Hansen, M., & Morrison, J. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013021 · Cited by 17
Pan, J., Li, W., Gu, L., Liu, C., Zhang, K., & Hong, G. (2022) · European Radiology · doi:10.1007/s00330-022-08826-z · Cited by 15
Zhang, X., Meng, Q.-W., Miao, R., & Huang, P. (2022) · Tuberculosis · doi:10.1016/j.tube.2022.102223 · Cited by 15
Yu, Q., Liu, Y., Hu, P., Gao, F., & Huang, G. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.837116 · Cited by 18
Cardona-Trujillo, M. C., Ocampo-Cárdenas, T., Tabares-Villa, F. A., Zuluaga‐Vélez, A., & Arias, J. C. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e10225 · Cited by 15
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.