QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 6,501–6,600 of 14,770
Youssef, A. R., & Gumaa, M. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1325319 · Cited by 17
Freeman, K., Taylor‐Phillips, S., Connock, M. J., Court, R. A., Tsertsvadze, A., Shyangdan, D., Auguste, P., Mistry, H., Arasaradnam, R. P., Sutcliffe, P. A., et al. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-014581 · Cited by 16
“Quality assessment Studies were quality assessed using a modified QUADAS-2 checklist.(11) Items included were method of patient selection, blinding of index test results, exclusion of uninterpretable test results from 2×2 table data and method of assessment of clinical status (the reference case).”
The diagnostic performance of 18F-FAMT PET and 18F-FDG PET for malignancy detection: a meta-analysis
Achmad, A., Bhattarai, A., Yudistiro, R., Heryanto, Y. D., Higuchi, T., & Tsushima, Y. (2017) · BMC Medical Imaging · doi:10.1186/s12880-017-0237-1 · Cited by 16
Zhang, Z., Brusasco, C., Anile, A., Corradi, F., Mariyaselvam, M. Z. A., Young, P., Almog, Y., Du, B., Yu, X., Zhu, H., et al. (2018) · Journal of Emergency and Critical Care Medicine · doi:10.21037/jeccm.2018.05.05 · Cited by 25
Kim, D. W., Yoon, H. M., Lee, J., Kim, J. H., Jung, A. Y., Lee, J. S., & Cho, Y. A. (2018) · Emergency Radiology · doi:10.1007/s10140-018-1624-9 · Cited by 16
Brinkman, M., Jentjens, S., Boone, K., Anten, M. H. M. E., Schrander-Stumpel, C. T. R. M., Nelemans, P. J., & van Kroonenburgh, M. J. P. G. (2018) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000889 · Cited by 16
Aldehyde dehydrogenase 1 as a predictor of the neoadjuvant chemotherapy response in breast cancer
Li, J., Zhang, B., Yang, Y. F., Jin, J., & Liu, Y. H. (2018) · Medicine · doi:10.1097/md.0000000000012056 · Cited by 16
Borja, L. S., Coelho, L. B., de Jesus, M. S., Queiroz, A. T. L., Celedón, P. A. F., Zanchin, N. I. T., da Silva, E. D., Ferreira, A., Krieger, M. A., Veras, P. S. T., et al. (2018) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0006871 · Cited by 16
Yousefifard, M., Sarveazad, A., Babahajian, A., Baikpour, M., Shokraneh, F., Vaccaro, A. R., Harrop, J. S., Fehlings, M. G., Hosseini, M., & Rahimi‐Movaghar, V. (2018) · Journal of Neurochemistry · doi:10.1111/jnc.14637 · Cited by 16
The diagnostic accuracy of liquid exosomes for lung cancer detection: a meta-analysis
Song, Z., Wang, S., & Liu, Y. (2018) · OncoTargets and Therapy · doi:10.2147/ott.s188832 · Cited by 16
“3 software.(12) The QUADAS-2 tool is composed of four key domains: patient selection, index test, reference standard, and flow and timing.”
A revised systematic review and meta‐analysis on the effect of statins on D‐dimer levels
Schol‐Gelok, S., Morelli, F., Arends, L. R., Boersma, E. H., Kruip, M. J. H. A., Versmissen, J., & van Gelder, T. (2019) · European Journal of Clinical Investigation · doi:10.1111/eci.13130 · Cited by 16
Chun, X., Lin, Y., Ma, J., He, J., Ye, L., & Yang, H. (2019) · Pediatric Research · doi:10.1038/s41390-019-0465-x · Cited by 16
State of the Art of Natural Killer Cell Imaging: A Systematic Review
Varani, M., Auletta, S., Signore, A., & Galli, F. (2019) · Cancers · doi:10.3390/cancers11070967 · Cited by 16
Virarkar, M., Ganeshan, D., Devine, C. E., Bassett, R. L., Kuchana, V., & Bhosale, P. (2019) · Clinical Imaging · doi:10.1016/j.clinimag.2019.11.018 · Cited by 16
Siempis, T., Tsakiris, C., Alexiou, G. Α., Xydis, V. G., Voulgaris, S., & Argyropoulou, M. I. (2019) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2019.105643 · Cited by 16
Li, K., Pei, Y., Wu, Y., Guo, Y. C., & Cui, W. (2020) · Journal of Ovarian Research · doi:10.1186/s13048-019-0605-2 · Cited by 16
Haber, M., Drake, A., & Nightingale, J. M. (2020) · Radiography · doi:10.1016/j.radi.2020.01.002 · Cited by 17
Ballová, V., Muoio, B., Albano, D., Bertagna, F., Canziani, L., Ghielmini, M. E. G., Ceriani, L., & Treglia, G. (2020) · Diagnostics · doi:10.3390/diagnostics10020101 · Cited by 16
Divala, T. H., Fielding, K., Kandulu, C. C., Nliwasa, M., Sloan, D. J., Gupta‐Wright, A., & Corbett, E. L. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30143-2 · Cited by 16
Singh, S., Singh, M., Verma, N., Sharma, M., Pradhan, P., Chauhan, A., Jaiswal, N., Chakrabarti, A., & Singh, M. (2020) · Medical Mycology · doi:10.1093/mmy/myaa038 · Cited by 18
Navarro, D. F., Sullivan, F., Azcoaga-Lorenzo, A., & Santiago, V. H. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033424 · Cited by 22
Rella, R., Contegiacomo, A., Bufi, E., Mercogliano, S., Belli, P., & Manfredi, R. M. (2020) · British Journal of Radiology · doi:10.1259/bjr.20200630 · Cited by 16
Lambert, P., Miguens, S. A. Q., Solda, C., Sganzerla, J. T., Reichert, L. A., Estrela, C., & Barletta, F. B. (2020) · Restorative Dentistry & Endodontics · doi:10.5395/rde.2020.45.e48 · Cited by 16
Cheng, L., Li, L., Liu, C., Yan, S., & Li, Y. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033880 · Cited by 18
D-dimer for diagnosis of periprosthetic joint infection: A meta-analysis
Yan, J., Xie, K., Jiang, X., Han, X., Wang, L., & Yan, M. (2020) · Journal of Orthopaedic Science · doi:10.1016/j.jos.2020.09.015 · Cited by 16
Zapf, A., Albert, C., Frömke, C., Haase, M., Hoyer, A., Jones, H. E., & Rücker, G. (2021) · Biometrical Journal · doi:10.1002/bimj.202000091 · Cited by 19
Noninvasive methods for bilirubin measurements in newborns: A report
Okwundu, C. I., & Saini, S. S. (2020) · Seminars in Perinatology · doi:10.1016/j.semperi.2020.151355 · Cited by 16
Ma, H.-Y., Chen, S., Cao, W.-D., & Min, C.-T. (2020) · Renal Failure · doi:10.1080/0886022x.2020.1853568 · Cited by 16
Zhang, Z., Zheng, B., Chen, W., Xiong, H. F., & Jiang, C. (2020) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2020.9595 · Cited by 16
Berner, J. E., Pereira, N., Troisi, L., Will, P. A., Nanchahal, J., & Jain, A. (2021) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2020.12.093 · Cited by 16
Kromm, J. A., Fiest, K. M., Alkhachroum, A. M., Josephson, C. B., Kramer, A. H., & Jetté, N. (2021) · Neurocritical Care · doi:10.1007/s12028-020-01172-2 · Cited by 18
Shu, X., Wu, G., Zhang, Y., Wang, Y., Zheng, Y., Guo, Q., Ji, R., & Zhou, Y. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-1051 · Cited by 21
Mander, G., & Munn, Z. (2021) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2021.02.005 · Cited by 17
Engbersen, M. P., Lahaye, M. J., Lok, C. A. R., Koole, S. N., Sonke, G. S., Beets‐Tan, R. G. H., & van Driel, W. J. (2021) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2021.03.233 · Cited by 18
Detecting serum galactomannan to diagnose acute invasive Aspergillus sinusitis: a meta-analysis
Chang, S. W., Nam, J. S., Ha, J., Kim, N. W., Almarzouq, W. F., Kim, C., Yoon, J., & Cho, H. (2021) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-021-06857-8 · Cited by 16
Zhan, Y., Zhang, G., Li, M., & Zhou, X. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633833 · Cited by 18
Paladino, L., Baron, B. J., Shan, G., & Sinert, R. H. (2021) · Academic Emergency Medicine · doi:10.1111/acem.14298 · Cited by 16
Urabe, F., Kimura, S., Yasue, K., Yanagisawa, T., Tsuzuki, S., Kimura, T., Miki, J., & Egawa, S. (2021) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2021.03.013 · Cited by 16
Guo, Y., Zhu, H., Yao, Z., Liu, F., & Yang, D. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109792 · Cited by 18
Luo, Y., Mao, M., Xiang, R., Han, B., Chang, J., Zuo, Z., Wu, F., & Kang-hua, M. (2021) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2021.05.004 · Cited by 16
Osei, E., Nkambule, S. J., Vezi, P. N., & Mashamba-Thompson, T. P. (2021) · Diagnostics · doi:10.3390/diagnostics11061081 · Cited by 19
Baker, H., Pilarski, N., Morton, V. H., & Morris, R. K. (2021) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2021.05.048 · Cited by 17
Pillay, S., Davies, G., Chaplin, M., de Vos, M., Schumacher, S. G., Warren, R. M., Steingart, K. R., & Theron, G. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014841 · Cited by 34
Aly, M. M., Al-Shoaibi, A. M., Fattani, A. A., & AlJuzair, A. H. (2021) · World Neurosurgery · doi:10.1016/j.wneu.2021.06.109 · Cited by 16
Alotaibi, A., Alghamdi, A., Reynard, C., & Body, R. M. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-045815 · Cited by 16
Adamou, A., Beltsios, E. T., & Papanagiotou, P. (2021) · Diagnostics · doi:10.3390/diagnostics11091620 · Cited by 20
de Krom, M. A. P., Kalmet, P. H. S., Jagtenberg, E. M., Hermus, J. P. S., van Vugt, R., Seelen, H. A. M., & Poeze, M. (2021) · Injury · doi:10.1016/j.injury.2021.09.034 · Cited by 16
Manfredi, C., Fernández‐Pascual, E., Arcaniolo, D., Emberton, M., Sánchez-Salas, R., Artigas, C., Bianco, F. J., Cathcart, P. J., Murphy, D. G., Couñago, F., et al. (2021) · European Urology Focus · doi:10.1016/j.euf.2021.08.013 · Cited by 16
Wong, M. L., Silva, L. O. J. E., Gerberi, D., Edlow, J. A., & Dubosh, N. M. (2021) · Academic Emergency Medicine · doi:10.1111/acem.14390 · Cited by 16
Aggarwal, N., Quaglia, A., McPhail, M. J. W., & Monahan, K. J. (2021) · International Journal of Colorectal Disease · doi:10.1007/s00384-021-04046-x · Cited by 76
Cholera Rapid Diagnostic Tests for the Detection of Vibrio cholerae O1: An Updated Meta-Analysis
Muzembo, B. A., Kitahara, K., Ohno, A., Debnath, A., Okamoto, K., & Miyoshi, S. (2021) · Diagnostics · doi:10.3390/diagnostics11112095 · Cited by 16
Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
Wang, Y., Li, N., & Qu, Y. (2021) · Jornal de Pediatria · doi:10.1016/j.jped.2021.10.003 · Cited by 16
Use of Smartphones for the Detection of Uterine Cervical Cancer: A Systematic Review
Champin, D., Ramírez-Soto, M. C., & Vargas-Herrera, J. (2021) · Cancers · doi:10.3390/cancers13236047 · Cited by 16
de Graaff, A. M., Cuijpers, P. J., Leeflang, M., Sferra, I., Uppendahl, J. R., de Vries, R., & Sijbrandij, M. (2021) · Cambridge Prisms Global Mental Health · doi:10.1017/gmh.2021.39 · Cited by 21
“Another limitation is related to the quality of studies, with 17 studies scoring high risk of bias on at least two QUADAS-2 domains.”
BackgroundMethodInfluentialSelf-citationGianola, S., Castellini, G., Biffi, A., Porcu, G., Napoletano, A., Coclite, D., D’Angelo, D., Fauci, A. J., Iacorossi, L., Latina, R., et al. (2021) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000003496 · Cited by 17
Jin, J., Liu, Y. H., & Zhang, B. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15930 · Cited by 16
Injury of the Thoracolumbar Posterior Ligamentous Complex: A Bibliometric Literature Review
Aly, M. M., Elemam, R., El-Sharkawi, M. M., & Hurlbert, R. J. (2022) · World Neurosurgery · doi:10.1016/j.wneu.2022.01.041 · Cited by 17
Ge, S., & Huang, C. (2022) · Journal of Thoracic Disease · doi:10.21037/jtd-21-1664 · Cited by 17
Ibraheem, S. A. W., Mahmud, R., Saini, S. M., Hassan, H. A., Keiteb, A. S., & Dirie, A. M. (2022) · Diagnostics · doi:10.3390/diagnostics12020541 · Cited by 16
Macedo, A. C. L., Prestes, G. D. S., Colonetti, T., Cândido, A. C. R., Uggioni, M. L. R., Gomes, A. C., Silva, F. R., Ceretta, L. B., Grande, A. J., & da Rosa, M. I. (2022) · Journal of Clinical Virology · doi:10.1016/j.jcv.2022.105121 · Cited by 16
Qu, E., Zhang, M., Ju, J., Chen, Y., Lin, X., & Zhang, X. (2022) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15988 · Cited by 16
Dondi, F., Albano, D., Bellini, P., Giulia, V., Giubbini, R., & Bertagna, F. (2022) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001566 · Cited by 16
Nomura, O., Hashiba, K., Kikuchi, M., Kojima, S., Hanada, H., Mano, T., Yamamoto, T., Nakashima, T., Tanaka, A., Nakayama, N., et al. (2022) · Circulation Reports · doi:10.1253/circrep.cr-22-0001 · Cited by 16
Sharrod–Cole, H., Fenn, J. S., Gama, R. M., Ford, C., Giri, R., & Luckraz, H. (2022) · Scientific Reports · doi:10.1038/s41598-022-10477-5 · Cited by 21
SARS-CoV-2 saliva testing using RT-PCR: a systematic review
Okoturo, E., & Amure, M. (2022) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2022.05.008 · Cited by 17
Llor, C., Moragas, A., Aguilar-Sánchez, M., García-Sangenís, A., Monfà, R., & Morros, R. (2022) · Family Practice · doi:10.1093/fampra/cmac058 · Cited by 19
Li, Y., Li, X., Zhang, B., Yu, Q., & Lu, Y. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2092100 · Cited by 16
Gao, J., Fan, Y.-Z., Gao, S., & Zhang, W. (2022) · Reproductive Sciences · doi:10.1007/s43032-022-01019-5 · Cited by 16
Roque, R., Cordeiro, M. R., Armas, M., Caramelo, F. J., Caseiro‐Alves, F., & Figueiredo-Dias, M. (2022) · npj Breast Cancer · doi:10.1038/s41523-022-00441-x · Cited by 16
Yang, L., Perry, E., Shan, L. L., Wilding, H., Connell, W., Thompson, A. J. V., Taylor, A. C. F., Desmond, P. V., & Holt, B. A. (2022) · Endoscopy International Open · doi:10.1055/a-1846-0642 · Cited by 17
Machine learning as a new horizon for colorectal cancer risk prediction? A systematic review
Kennion, O., Maitland, S., & Brady, R. R. W. (2022) · Health Sciences Review · doi:10.1016/j.hsr.2022.100041 · Cited by 16
Jerome, E., Cavazza, A., Menon, K., & McPhail, M. J. W. (2022) · Transplant Immunology · doi:10.1016/j.trim.2022.101675 · Cited by 16
Ramlee, S., Hulse, D., Bernatowicz, K., Pérez-López, R., Sala, E., & Aloj, L. (2022) · Cancers · doi:10.3390/cancers14153656 · Cited by 18
de Mendonça, D. S., Ribeiro, E. C., Silva, P. G. D. B., Rodrigues, A. A., Kurita, L. M., de Aguiar, A. S. W., Tuji, F. M., Neves, F. S., Carvalho, F. S. R., & Costa, F. W. G. (2022) · Journal of Forensic Sciences · doi:10.1111/1556-4029.15117 · Cited by 16
Duncan, D. B., Mackett, K., Ali, M. U., Yamamura, D. L. R., & Balion, C. M. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.08.004 · Cited by 16
Watson, E. L., Patel, B., Katsogridakis, E., Pepper, C., Messeder, S. J., Saratzis, A. N., Zubair, M., Nicholls, J. K., Chung, E. M. L., & Bown, M. J. (2022) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2022.08.008 · Cited by 19
Siltari, A., Lönnerbro, R., Pang, K. H., Ширанов, К. А., Asiimwe, A., Axelsson, S. E., Franks, B., Kiran, A., Murtola, T. J., Schalken, J. A., et al. (2022) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2022.09.006 · Cited by 20
Reconsidering evidence-based management of endometriosis
Koninckx, P. R., Ussia, A., Al-Suwaidi, S., Amro, B., Keckstein, J., Adamyan, L. V., Donnez, J., Dan, M. C., & Wattiez, A. (2022) · Facts Views and Vision in ObGyn · doi:10.52054/fvvo.14.3.033 · Cited by 18
Lu, W., Tian, F., Ma, J., Zhong, Y., Liu, Z., & Xue, L. (2022) · Frontiers in Immunology · doi:10.3389/fimmu.2022.1023451 · Cited by 16
Weeda, Y. A., Kalisvaart, G. M., van Velden, F. H. P., Gelderblom, H. A. J., van der Molen, A. J., Bovée, J. V. M. G., van der Hage, J. A., Grootjans, W., & de Geus‐Oei, L. (2022) · Diagnostics · doi:10.3390/diagnostics12112722 · Cited by 16
“To assess applicability concerns and the risk of bias in articles covering the topic of monitoring, the Quality Assessment of Diagnostic Accuracy Studies Tool, Version 2 (QUADAS-2) was applied [17].”
Clemente, B., Pineda-Cortel, M. R., & Villaflores, O. B. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11829 · Cited by 16
Fulgione, C., Raffone, A., Travaglino, A., Arciuolo, D., Santoro, A., Cianfrini, F., Russo, D., Varricchio, S., Raimondo, I., Inzani, F. S., et al. (2022) · Pathology - Research and Practice · doi:10.1016/j.prp.2022.154261 · Cited by 16
Diagnostic and Prognostic Value of microRNAs in Patients with Laryngeal Cancer: A Systematic Review
Broseghini, E., Filippini, D. M., Fabbri, L., Leonardi, R., Abeshi, A., Molin, D. D., Fermi, M., Ferracin, M., & Fernandez, I. J. (2023) · Non-Coding RNA · doi:10.3390/ncrna9010009 · Cited by 20
Validity of ultrasonography in detecting enthesitis in children: A systematic literature review
Rossi‐Semerano, L., Ravagnani, V., Collado, P., Vojinović, J., Roth, J., Magni‐Manzoni, S., Naredo, E., D’Agostino, M. A., & Jousse‐Joulin, S. (2023) · Joint Bone Spine · doi:10.1016/j.jbspin.2023.105538 · Cited by 16
Asyura, M. M. A. Z., Komariah, M., Amirah, S., Faisal, E. G., Maulana, S., Platini, H., & Pahria, T. (2023) · International Journal of Preventive Medicine · doi:10.4103/ijpvm.ijpvm_156_22 · Cited by 18
Rane, B. M., Malau‐Aduli, B. S., Alele, F. O., & O’Brien, C. M. (2023) · AJOG Global Reports · doi:10.1016/j.xagr.2023.100241 · Cited by 22
Riccò, M., Corrado, S., Palmieri, S., & Marchesi, F. (2023) · Children · doi:10.3390/children10071169 · Cited by 20
Liao, W., Mukundan, A., Sadiaza, C., Tsao, Y.-M., Huang, C., & Wang, H. (2023) · Biomedical Optics Express · doi:10.1364/boe.492635 · Cited by 17
Tabchi, Y., Zaoui, F., & Bahoum, A. (2023) · International Orthodontics · doi:10.1016/j.ortho.2023.100802 · Cited by 16
Tekin, A., Truong, H. H., Rovati, L., Lal, A., Gerberi, D., Gajic, O., & O’Horo, J. C. (2023) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofad442 · Cited by 16
“) independently assessed the methodological quality of the included studies [21].”
Lee, S., Kim, Y., Shin, J., Roh, Y. H., Choi, J., Chernyak, V., & Sirlin, C. B. (2023) · European Radiology · doi:10.1007/s00330-023-10134-z · Cited by 16
“The following domains were assessed: patient and observation selection, index test, reference standard, and flow and timing [14].”
Dai, X., Zhao, B., Zang, J., Wang, X., Liu, Z., Sun, T., Yu, H., & Sui, X. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.03.033 · Cited by 16
Maclachlan, L., White, S., & Reid, D. A. (2015) · Europe PMC (PubMed Central) · Cited by 26
Diagnostic value of circulating microRNAs for hepatocellular carcinoma
Yang, Y., & Zhu, R. (2014) · Molecular Biology Reports · doi:10.1007/s11033-014-3578-7 · Cited by 16
Efectividad del Mini-Mental en la detección del deterioro cognitivo en Atención Primaria
Pardo, C. C., Cruz, I., Espejo-Martínez, B., Viedma, S. C., García, P. T., & Rodríguez, J. O. (2013) · Atención Primaria · doi:10.1016/j.aprim.2013.04.009 · Cited by 28
Cog-4 Has Limited Diagnostic Test Accuracy and Validity for Cognitive Assessment in Stroke Survivors
Lees, R., Lua, J., Melling, E., Miao, Y., Tan, J. L., & Quinn, T. J. (2014) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2013.12.042 · Cited by 17
Dorleijn, D. M. J., Luijsterburg, P. A. J., Bierma‐Zeinstra, S., & Bos, P. K. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.12.008 · Cited by 16
Quick Guide to Systematic Reviews and Meta-analysis
Koelemay, M. J. W., & Vermeulen, H. (2015) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2015.11.010 · Cited by 16
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.