QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 8,701–8,800 of 14,770
Predictive model for the probability of malignancy in solitary pulmonary nodules: a meta-analysis
Chen, G., Bai, T., Wen, L., & Li, Y. (2022) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-022-01859-x · Cited by 8
Li, R., Tian, X., Pang, J., Li, L., Yuan, J., Tian, Z., & Wang, Z. (2022) · Viruses · doi:10.3390/v14071355 · Cited by 8
Attar, A., Hosseinpour, A., Hosseinpour, H., Rezaeian, N., Abtahi, F., Mehdizadeh, F., Parsaee, M., Akiash, N., Behjati, M., Meloni, A., et al. (2022) · Cardiovascular Ultrasound · doi:10.1186/s12947-022-00291-4 · Cited by 10
Tsang, N. N. Y., So, H. C., Cowling, B. J., Leung, G. M., & Ip, D. (2022) · European Respiratory Review · doi:10.1183/16000617.0014-2022 · Cited by 8
Oerther, B., Schmucker, C. M., Schwarzer, G., Schoots, I. G., Sigle, A., Gratzke, C., Bamberg, F., & Benndorf, M. (2022) · BMJ Open · doi:10.1136/bmjopen-2022-066327 · Cited by 8
Nugent, J. T., Jiang, K., Funaro, M. C., Saran, I., Young, C., Ghazi, L., Bakhoum, C. Y., Wilson, F. P., & Greenberg, J. H. (2023) · JAMA · doi:10.1001/jama.2023.3184 · Cited by 9
Klowak, J. A., Nguyen, A. V., Malik, A., Hornby, L., Doig, C. J., Kawchuk, J., Sekhon, M. S., & Dhanani, S. (2023) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-023-02424-3 · Cited by 9
“The risk of bias was assessed independently in duplicate for our study question specifically using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool.(9) We reviewed four domains: 1) patient selection; 2) index tests; 3) reference standard; and 4) flow and timing.”
Yuan, X., Ye, M., & Ou, S. (2023) · Medicine · doi:10.1097/md.0000000000033872 · Cited by 8
Schueler, S., Walther, S., Schuetz, G. M., Schlattmann, P., & Dewey, M. (2013) · European Radiology · doi:10.1007/s00330-012-2763-0 · Cited by 8
MicroRNA-145 as ideal biomarker for the diagnosis of various carcinomas
Hou, Y., Wang, X., Chen, Y., & Mu, S. (2014) · Tumor Biology · doi:10.1007/s13277-014-2886-9 · Cited by 8
Raichand, S., Moore, D., Riley, R. D., Lordkipanidzé, M., Dretzke, J., O’Donnell, J., Jowett, S. M., Bayliss, S. E., & Fitzmaurice, D. A. (2013) · Systematic Reviews · doi:10.1186/2046-4053-2-16 · Cited by 8
Freshwater, M. F. (2015) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2015.06.012 · Cited by 12
Shuxin, Z., & Liu, Y. (2016) · Medicine · doi:10.1097/md.0000000000003571 · Cited by 8
Jia, H., Ma, X., Zhao, Y., Zhao, J., Liu, R., Chen, Z., Chen, J., Huang, J.-W., Li, Y., Zhang, J., et al. (2015) · PubMed Central · Cited by 8
Automated tests for diagnosing and monitoring cognitive impairment: a diagnostic accuracy review
Aslam, R. W., Bates, V., Dundar, Y., Hounsome, J. C., Richardson, M., Krishan, A., Dickson, R., Boland, A., Kotas, E., Fisher, J. D., et al. (2016) · Health Technology Assessment · doi:10.3310/hta20770 · Cited by 8
von Niederhäusern, B., Schandelmaier, S., Bonde, M. M., Brunner, N., Hemkens, L. G., Rutquist, M., Bhatnagar, N., Guyatt, G. H., Pauli‐Magnus, C., & Briel, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180635 · Cited by 10
You, M., & Yun, S. J. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26035 · Cited by 8
Peng, Z., Wenru, Z., Dai, J., & Fang, J. (2018) · Cellular and Molecular Biology · doi:10.14715/cmb/2018.64.6.14 · Cited by 9
Mahajan, P. B., & Mukherjee, S. (2018) · Journal of Drug Assessment · doi:10.1080/21556660.2018.1487446 · Cited by 11
Oltra-Sastre, M., Fuster‐García, E., Juan–Albarracín, J., Sáez, C., Pérez‐Girbés, A., Sanz‐Requena, R., Revert-Ventura, A. J., Salcedo, A. M., Urchueguía, J. F., Hervás, A., et al. (2019) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405615666190109100503 · Cited by 8
Clinicopathological factors associated with BRAF ‐V600E mutation in colorectal serrated adenomas
Travaglino, A., D’Armiento, F. P., Cassese, G., Campanino, M. R., Borrelli, G., Pignatiello, S., Luglio, G., Maione, F., Palma, G. D. D., & D'Armiento, M. R. (2019) · Histopathology · doi:10.1111/his.13846 · Cited by 8
Souza, R. T., Galvão, R. B., Leite, D. F. B., Passini, R., Jr., Baker, P. N., & Cecatti, J. G. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-026033 · Cited by 8
Seccombe, A., McCluskey, L., Moorey, H. C., Lasserson, D. S., & Sapey, E. (2019) · Journal of General Internal Medicine · doi:10.1007/s11606-019-05073-9 · Cited by 9
Laher, A. E., Swart, M., Honiball, J., Perera, M., Lawrentschuk, N., & Adam, A. (2019) · ANZ Journal of Surgery · doi:10.1111/ans.15402 · Cited by 8
Chen, H., Wang, K., Pei, D., & Xu, H. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23303 · Cited by 8
Kim, D., & Kim, S. (2020) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001194 · Cited by 8
Chen, K., Ahmed, S., Sheng, Y.-J., Sun, C., Deng, C., & Ojha, S. C. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00363-20 · Cited by 8
Sun, P., Guo, Z. H., & Zhang, H. B. (2020) · BioMed Research International · doi:10.1155/2020/2679539 · Cited by 8
Peppa, M., Minassian, C., Mangtani, P., & Thomas, S. L. (2021) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.5251 · Cited by 10
Burti, S., Zotti, A., Contiero, B., & Banzato, T. (2021) · The Veterinary Journal · doi:10.1016/j.tvjl.2021.105773 · Cited by 8
Bossuyt, P. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.192997 · Cited by 10
Self-citationIs salivary gland ultrasonography a useful tool in Sjögren’s syndrome?
Fox, R. I. (2016) · Rheumatology · doi:10.1093/rheumatology/kev409 · Cited by 8
Palaniyappan, L. K., Maayan, N., Kirkham, A. J., Davenport, C. F., Khodabakhsh, A., Adams, C. E., & Soares‐Weiser, K. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011021 · Cited by 8
Hein, I. M., Daams, J. G., Troost, P. W., Lindeboom, R., & Lindauer, R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011099 · Cited by 8
RetractedMalde, S., Nambiar, A., Umbach, R., Lam, T. B., Bach, T., Bachmann, A., Drake, M. J., Gacci, M., Gratzke, C., Madersbacher, S., et al. (2018) · European Urology Supplements · doi:10.1016/s1569-9056(18)32052-9 · Cited by 8
Mudrik, A., Tsur, A., Nadkarni, G. N., Efros, O., Glicksberg, B. S., Soffer, S., & Klang, E. (2024) · medRxiv · doi:10.1101/2024.08.08.24311699 · Cited by 11
Prompt Engineering in Large Language Models for Patient Education: A Systematic ReviewPreprint
Mudrik, A., Nadkarni, G. N., Efros, O., Soffer, S., & Klang, E. (2025) · medRxiv · doi:10.1101/2025.03.28.25324834 · Cited by 15
Dang, A., Dang, D., & Vallish, B. N. (2023) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_555_20 · Cited by 7
Yan, X.-X., Zhang, Y., Zhang, Y., Yang, Y., & Wu, D. (2024) · Chinese Medical Sciences Journal · doi:10.24920/004307 · Cited by 7
Li, X., Fu, G., Zhang, C., Wu, Y. Q., Guo, H., Li, W., & Zeng, X. (2024) · International Journal of COPD · doi:10.2147/copd.s457172 · Cited by 7
Screening for Autism Spectrum Disorder in Young Children: Still Not Enough Evidence
Grigore, B., Peters, J., Williams, J., Russell, G., Coles, P., Visintin, C., Rogers, M., Hayward, R. C., Zhelev, Z., Logan, S., et al. (2024) · Journal of Primary Care & Community Health · doi:10.1177/21501319241263223 · Cited by 10
Pan, S., Holdefer, R. N., Wu, H., Li, C., & Guo, L. (2024) · Clinical Neurophysiology · doi:10.1016/j.clinph.2024.07.021 · Cited by 7
Vella, S., Lauri, J., & Grech, R. (2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8442 · Cited by 7
Can artificial intelligence aid the urologists in detecting bladder cancer?
Hengky, A., Lionardi, S. K., & Kusumajaya, C. (2024) · Indian Journal of Urology · doi:10.4103/iju.iju_39_24 · Cited by 7
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool, [14] a validated tool for assessing the quality of diagnostic accuracy studies, was used to evaluate the quality of each study.”
Belay, F. W., Fikre, R., Alemayehu, A., Clarke, A., Williams, S., Richards, H., Kassa, Y. C., & Belayneh, F. (2024) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2024-002741 · Cited by 8
Diagnostic Utility of Immunofluorescence in Oral Lesions: a Systematic Review
Arockiam, S., Raj, B. S. H., Prabha, N., & Dharani, M. (2024) · Journal of Oral and Maxillofacial Research · doi:10.5037/jomr.2024.15302 · Cited by 7
Elbarbary, N., Pritsini, F., Kazi, A., Wang, C., Thilaganathan, B., & Bhide, A. (2024) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.18040 · Cited by 7
“Risk of bias assessment for included studies was performed by two reviewers (NE and AK) through the critical appraisal using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [18], which is the recommended tool by the Cochrane Handbook of Diagnostic Test Accuracy Studies.”
Neuroimage Signature in Post-Stroke Pain: A Systematic Review
Buzhanskyy, A., Duarte, I. C., Pato, M. V., Donato, H., Castelo-Branco, M. S., Abejas, A. G., & Lapa, T. A. S. C. (2025) · Current Pain and Headache Reports · doi:10.1007/s11916-024-01339-y · Cited by 7
“Another prevalent limitation is regarding to “ Flow and Timing ” [ 32 ] which represents a high risk of introducing bias, as CPSP may take up to six months to show initial symptoms.”
Barbosa, I. O. F., de Oliveira, B. C., Santos, C. K. M., Miranda, M. C. R., Barbosa, G. A., & Menezes, A. D. S. (2025) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2024.0579 · Cited by 7
Comparison of conventional two-dimensional and digital three-dimensional imaging in orthodontics
Haude, A.-M., Lehmann, T., Hennig, C., & Jacobs, C. (2025) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-024-00574-7 · Cited by 7
Can we trust published evidence on point-of-care tests for cholesterol? A rapid review
Mutepfa, C. C., Hicks, T., Winter, A., Dickinson, R. E., Williams, C., Harrison, N., Chidanyika, J., Newton, J. L., Jones, W. S., & Suklan, J. (2025) · BMJ Open · doi:10.1136/bmjopen-2023-080726 · Cited by 8
“Only one paper by Donato et al 26”
Wu, J., Yao, Y., Wang, T., Xu, T., & Jiang, R. (2025) · Hypertension in Pregnancy · doi:10.1080/10641955.2025.2487794 · Cited by 7
“The evaluation of the literature was conducted utilizing the Cochrane risk of bias tool, a rigorous method designed to assess the potential for bias in research studies (22,23).”
She, L.-Z., Li, Y., Wang, H., Zhang, J., Zhao, Y., Cui, J., & Qiu, L. (2025) · Journal of Medical Internet Research · doi:10.2196/71091 · Cited by 7
“To comprehensively assess the quality of included studies, we adapted a recognized tool, the revised Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [24], by replacing certain criteria with more relevant ones from the Prediction Model Risk of Bias Assessment Tool (PRO-BAST) [25].”
Bacal, V., Li, A., Shapiro, H. M., Rana, U., Zwingerman, R., Avery, L. M., Palermo, A., Philipoppolous, E., & Chan, C. (2025) · PLoS ONE · doi:10.1371/journal.pone.0321859 · Cited by 7
“Quality of individual studies was determined using the QUADAS-2 tool for diagnostic accuracy [12].”
Wang, K., Echeagaray, A. R., Campbell, S., Bohm, C. J., Tennankore, K., Thompson, S., Bello, A. K., Pannu, N., Bathini, L., McIsaac, M., et al. (2025) · Kidney Medicine · doi:10.1016/j.xkme.2025.101037 · Cited by 8
Ferri, N., Bracci, A., Franceschelli, G. M., Gnoli, G., Turolla, A., Pillastrini, P., Manzari, L., & Tramontano, M. (2025) · Journal of Neurology · doi:10.1007/s00415-025-13174-1 · Cited by 7
“Risk of bias was assessed using the Quality Assessment of Diagnostic Test Accuracy Studies 2 (QUADAS-2) tool [29], which evaluates diagnostic studies across four domains: patient selection, index test, reference standard, and flow and timing.”
Kwee, R. M., & Kwee, T. C. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112230 · Cited by 10
Bhattacharyya, N. K., Sastimoglu, Z., Armstrong, D., Selvaganapathy, P. R., & Deen, M. J. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110561 · Cited by 7
Alhyari, R., Ross, P. J., Sacco, R., AlHadidi, A., Mitchell, J., Khalaf, K., & Lalli, A. (2025) · BMC Oral Health · doi:10.1186/s12903-025-06589-9 · Cited by 7
“ROBINS-I was selected over QUADAS-2 due to the clinical rather than purely diagnostic accuracy focus of this review [15, 16].”
Kakar, M. T., Ramani, A. K., Kumar, A., Lal, A., Lohana, D. K., Radhika, F. N. U., Mushtaq, A., Shaikh, S., Kamran, R., Kumari, J., et al. (2025) · JGH Open · doi:10.1002/jgh3.70248 · Cited by 7
“The methodological quality and risk of bias of the included studies were assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool [8], which is specifically designed for evaluating diagnostic accuracy studies.”
Patil, S., Karabacak, M., Aydin, S., Sagi, I., Soddu, A., Ozkara, B. B., Margetis, K. D., & Bisdas, S. (2025) · Journal of Neurotrauma · doi:10.1177/08977151251363258 · Cited by 11
Lohner, V., Badhwar, A., Detcheverry, F. E., García, C. L., Gellersen, H. M., Khodakarami, Z., Lattmann, R., Li, R., Low, A., Mazo, C., et al. (2025) · Alzheimer s Research & Therapy · doi:10.1186/s13195-025-01815-6 · Cited by 11
Ultrasound screening for vasa previa: a systematic review and meta-analysis
Donovan, B. M., Bonanni, G., Javinani, A., Bain, P. A., Litman, E. A., Lucarelli, E., Bronsteen, R. A., Odibo, A. O., Shamshirsaz, A. A., & Oyelese, Y. (2025) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2025.08.003 · Cited by 8
Sapantzoglou, I., Antsaklis, P., Pergialiotis, V., Chatziioannou, M. I., Fasoulakis, Z. N., Daskalaki, M. A., Thomakos, N., Daskalakis, G., & Theodora, M. (2025) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.70002 · Cited by 10
Li, S., Liu, S., Zhao, X., Chen, W., Fan, B., Wong, M. S., Li, J., & Jiang, M. (2025) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2025.08.009 · Cited by 7
Tseriotis, V., Arrambide, G., Contentti, E. C., Tur, C., Wattjes, M. P., Cortese, R., Mitsikostas, D. D., Grigoriadis, N., Adamou, A., Chlorogiannis, D., et al. (2025) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2025-336694 · Cited by 8
Xydias, E. M., Emmanouil, V., Koutini, M., Ntanika, A., Tsakos, E., Prior, M., Sarris, I., Thanasas, I., Daponte, A. I., & Ziogas, A. C. (2025) · Medical Sciences · doi:10.3390/medsci13030168 · Cited by 8
“For diagnostic accuracy studies, the QUADAS-2C tool (4 September 2021 version) [16] was used for the assessment of the applicability and risk of bias, which was also indicated by the Cochrane Handbook for diagnostic test accuracy reviews [15].”
Li, Y., Wang, X., Zhu, H., & Ye, W. (2025) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2025.08.021 · Cited by 7
Tobaiqi, M. A., Alshamrani, M. N., Sriram, S., Mahmoud, A. B., Fadlalmola, H. A., & Albadrani, M. S. (2025) · Diagnostics · doi:10.3390/diagnostics15182343 · Cited by 11
von Quednow, E., Husain, N., Łajczak, P. M., Secco, G. L., & Koppanatham, A. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.2111005 · Cited by 9
Bunnell, A., Valdez, D., Strand, F., Glaser, Y., Sadowski, P., & Shepherd, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0001019 · Cited by 12
Maung, S. T., Tangkijvanich, P., & Chaiteerakij, R. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-05184-4 · Cited by 8
Ndaa, M., Pandya, P., Swensson, J., Samala, N. R., Ajaz, S., Joshi, D., Ayoub, W. S., & Akisik, F. M. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.09.205 · Cited by 12
Sadeghpour, S., Aghaee, A., Ahmadzadehfar, H., Rizzo, A., Treglia, G., & Sadeghi, R. (2025) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07576-6 · Cited by 7
Abdlkadir, A. S., Ardalan, Z. S., Scott, A. M., Hammad, H. T., Al-Adhami, D. A., Giesel, F. L., & Al‐Ibraheem, A. (2025) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07608-1 · Cited by 8
Diagnostic performance of artificial intelligence for facial fracture detection: a systematic review
Tuygunov, N., Boymuradov, S. A., Khurshid, Z., Songsiripradubboon, S., Abdulahtov, J., & Khatamov, U. (2025) · Oral Radiology · doi:10.1007/s11282-025-00878-3 · Cited by 10
AI in Esophageal Motility Disorders: Systematic Review of High-Resolution Manometry Studies
Gong, E. J., Bang, C. S., Lee, J. J., & Baik, G. H. (2025) · Journal of Medical Internet Research · doi:10.2196/85223 · Cited by 7
FujiLAM assays for tuberculosis detection in people with HIV: a systematic review and meta-analysis
Taye, B., Tesfaye, H., & Churiso, G. (2025) · BMC Infectious Diseases · doi:10.1186/s12879-025-12055-2 · Cited by 8
“Two reviewers (BT and HT) independently assessed the methodological quality of included studies using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [37].”
Patil, A. V., Mungase, S. B., Nadella, M., & Adela, R. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120787 · Cited by 7
Sahrai, H., Behnood, J., Baradaran, M., Khalaji, A., Norouzi, A., Shojaeshafiei, F., Ebrahimi, S. M. S., Mohammadzadeh, S., HajiEsmailPoor, Z., & Shahidi, R. (2025) · BMC Cancer · doi:10.1186/s12885-025-15446-5 · Cited by 7
Gatta, E., Pirola, I., Gandossi, E., Maltese, V., Bellini, P., Morandi, R., Lombardi, D., Delbarba, A., Marini, F., Casella, C., et al. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.12.003 · Cited by 8
Palani, B. S., Rathee, M., Tomar, S. S., & Singla, S. (2025) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2025.12.003 · Cited by 9
Elhaie, M., Koozari, A., & Mozafari, M. H. (2025) · Skeletal Radiology · doi:10.1007/s00256-025-05104-z · Cited by 7
“The methodological quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) tool [21].”
Çelik, A., & Hamdioğlu, E. (2026) · Internal and Emergency Medicine · doi:10.1007/s11739-025-04255-0 · Cited by 8
Sahu, V. (2026) · Journal of Open Research Software · doi:10.5334/jors.635 · Cited by 7
de Oliveira, G. S., Altmayer, S., Torri, G. B., Prediger, J. E., Abreu‐Gomez, J., Ghai, S., Haider, M. A., Ghezzi, C. L. A., Andrade, R. G. F., Ponsiglione, A., et al. (2026) · European Urology · doi:10.1016/j.eururo.2026.01.030 · Cited by 10
Vitthala, S., Nedelcu, S., Toukhy, T. E., & Maheshwari, A. (2026) · Human Fertility · doi:10.1080/14647273.2026.2618228 · Cited by 9
Woime, A. W. (2026) · BMC Public Health · doi:10.1186/s12889-026-26722-9 · Cited by 7
“Criteria for test application followed recommendations from Whiting et al. (2011) [89].”
Katsigianni, S., & Koutsouraki, E. (2026) · Molecular Neurobiology · doi:10.1007/s12035-026-05914-9 · Cited by 9
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to evaluate the risk of bias and applicability across four domains: patient selection, index test, reference standard, and flow/timing [70].”
Ellis, L. B., Tighe, J., Bowden, S. J., Kechagias, K. S., Paraskevaidi, M., Garg, A., Paraskevaidis, E., Arbyn, M., Veroniki, A. A., Kalliala, I. E. J., et al. (2026) · European Journal of Cancer · doi:10.1016/j.ejca.2026.116823 · Cited by 8
Diagnostic Accuracy of Serum Kallikrein-Related Peptidases for Ovarian Cancer
Zhu, L., Wang, F., Yu, X., Zeng, X., & Xi, M. (2016) · International Journal of Gynecological Cancer · doi:10.1097/igc.0000000000000781 · Cited by 7
Brañez‐Condorena, A., Goicochea-Lugo, S., Zafra‐Tanaka, J. H., Becerra-Chauca, N., Failoc‐Rojas, V. E., Herrera‐Añazco, P., & Taype-Rondán, Á. (2021) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2020.0707.r1.150321 · Cited by 7
Aarntzen, E. H. J. G., Noriega-Álvarez, E., Artiko, V. M., Dias, A. H., Gheysens, O. S., Glaudemans, A. W. J. M., Lauri, C., Treglia, G., WYNGAERT, T. V. D., van Leeuwen, F. W. B., et al. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00820-8 · Cited by 7
A Systematic Review of Clinical Vestibular Symptom Triage, Tools, and Algorithms
Lampasona, G., Piker, E. G., Ryan, C., Gerend, P. L., Rauch, S. D., Goebel, J. A., & Crowson, M. G. (2021) · Otolaryngology · doi:10.1177/01945998211032912 · Cited by 7
Chen, Z., Liu, H., Zhang, Y., Jin, T., Hu, J.-K., & Yang, K. (2021) · Journal of Investigative Surgery · doi:10.1080/08941939.2021.1972185 · Cited by 7
Singh, K., Cheung, B. M. Y., & Xu, A. (2021) · Biomarkers in Medicine · doi:10.2217/bmm-2021-0219 · Cited by 8
Canakis, A. (2022) · Annals of Gastroenterology · doi:10.20524/aog.2022.0741 · Cited by 7
Rogalska, M., Antkowiak, Ł., Kasperczuk, A., & Ścierski, W. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11247360 · Cited by 7
Reilly, J., Meurk, C., Heffernan, E., & Sara, G. E. (2023) · Australian & New Zealand Journal of Psychiatry · doi:10.1177/00048674221148394 · Cited by 8
Wang, H., Hong, M., Ding, L., & Song, B. (2023) · Thoracic Cancer · doi:10.1111/1759-7714.14808 · Cited by 7
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.