QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 8,201–8,300 of 14,770
Lee, S. E., Han, S., Kang, C. M., Kwon, W., Paik, K. Y., Song, K. B., Yang, J. D., Chung, J. C., Jeong, C., & Kim, S. (2022) · Annals of Hepato-Biliary-Pancreatic Surgery · doi:10.14701/ahbps.22-009 · Cited by 9
Zhang, X., Yao, J., Zhang, Y., Huang, X., Wang, W., & Huang, H. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.844390 · Cited by 9
Presepsin as a diagnostic biomarker of peri-prosthetic joint infection: a review of the literature
Delva, M. L., Samuel, L. T., Acuña, A. J., & Kamath, A. F. (2022) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-022-03232-z · Cited by 9
Inoue, T., Ishihara, R., Shibata, T., Suzuki, K., Kitagawa, Y., Miyazaki, T., Yamaji, T., Nemoto, K., Oyama, T., Muto, M., et al. (2022) · Esophagus · doi:10.1007/s10388-022-00918-5 · Cited by 9
Ye, X., Wang, L., & Jin, Z. (2022) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365521.2022.2067785 · Cited by 10
Park, S., & Han, K. S. (2022) · Current Alzheimer Research · doi:10.2174/1567205019666220404104854 · Cited by 9
Fonteyn-Vinke, A., Huurneman, B., & Boonstra, F. N. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.898719 · Cited by 9
Kelly, E., Whelan, S. O., Harriss, E., Murphy, S., Pollard, A. J., & Connor, D. O. (2022) · EBioMedicine · doi:10.1016/j.ebiom.2022.104110 · Cited by 9
Twine, C. P., & Mani, K. (2022) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2022.07.045 · Cited by 9
Aggarwal, A. N., Agarwal, R., Dhooria, S., Prasad, K. T., Sehgal, I. S., & Muthu, V. (2022) · Cytokine · doi:10.1016/j.cyto.2022.156019 · Cited by 11
Yan, X., Lv, K., Xiao, M., Tan, L., Gui, Y., Zhang, J., Chen, X., Jia, W., & Li, J. (2022) · Translational Cancer Research · doi:10.21037/tcr-22-601 · Cited by 11
Mo, Y. W., Choi, J. H., & Lee, W. J. (2022) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2022.10.014 · Cited by 9
Singh, S., Beyrer, J. K., Zhou, X., Swerdel, J. N., Harvey, R. A., Hornbuckle, K., Russo, L., Ghauri, K., Abi‐Elias, I. H., Cox, J. S., et al. (2022) · Drug Safety · doi:10.1007/s40264-022-01254-4 · Cited by 9
Khawaja, A. M., McNulty, J. J., Thakur, U. V., Chawla, S., Devi, S., Liew, A., Mirshahi, S., Du, R., Mekary, R. A., & Gormley, W. B. (2022) · Neurosurgical Review · doi:10.1007/s10143-022-01913-1 · Cited by 9
Li, J., Ye, Z., Hu, X., Hou, S., & Hang, Q. (2022) · Cancers · doi:10.3390/cancers14246187 · Cited by 9
Mendelsohn, S. C., Verhage, S., Mulenga, H., Scriba, T. J., & Hatherill, M. (2023) · Gates Open Research · doi:10.12688/gatesopenres.14327.1 · Cited by 10
Gil-Rodríguez, J., Martos-Ruíz, M., Fernández, A. B., Aranda-Laserna, P., Alonso, M. Á. M., Peregrina-Rivas, J.-A., Reyes, D. F., Carazo, J. M. D. V., Guirao‐Arrabal, E., & Hernández‐Quero, J. (2023) · Medicina Clínica · doi:10.1016/j.medcli.2023.01.024 · Cited by 11
Ko, W. S., & Kim, S. (2023) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000004639 · Cited by 9
Bautista, M., Cave, D. G. W., Downey, C. L., Bentham, J. R., & Jayne, D. G. (2023) · Journal of Clinical and Translational Science · doi:10.1017/cts.2023.557 · Cited by 10
Machine learning for malignant versus benign focal liver lesions on US and CEUS: a meta-analysis
Jorge, C. A. C., Castanha, E. B., Vilardo, M., Staziaki, P. V., Francisco, M. Z., Mohajer, B., Watte, G., de Moraes, F. Y., Hochhegger, B., & Altmayer, S. (2023) · Abdominal Radiology · doi:10.1007/s00261-023-03984-0 · Cited by 9
Diagnostic test accuracy of ultrasound for orbital cellulitis: A systematic review
Anwar, M. R., Mahant, S., Agbaje-Ojo, T., Mahood, Q., Borkhoff, C. M., Parkin, P. C., & Gill, P. J. (2023) · PLoS ONE · doi:10.1371/journal.pone.0288011 · Cited by 9
Hu, T., Zhang, Z., Song, F., Zhang, W., & Yang, J. (2023) · The Turkish Journal of Gastroenterology · doi:10.5152/tjg.2023.22812 · Cited by 15
Ariesen, A. D., Tuomainen, R. E., Deyn, P. P. D., Tucha, O. M., & Koerts, J. (2023) · Neuropsychology Review · doi:10.1007/s11065-023-09597-0 · Cited by 11
Bhalla, D., Rangarajan, K., Chandra, T., Banerjee, S., & Arora, C. (2023) · Indian journal of radiology and imaging - new series/Indian journal of radiology and imaging/Indian Journal of Radiology & Imaging · doi:10.1055/s-0043-1775737 · Cited by 11
Santoso, A., Rasiha, R., Zainal, A. T. F., Khairunnisa, I. N., Fais, M. K., & Gunawan, A. M. A. K. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-070377 · Cited by 11
Midtgaard, M., Pedersen, M. R. V., Christensen, N. L., McKnight, L., & Jensen, J. (2023) · Journal of Clinical Imaging Science · doi:10.25259/jcis_82_2023 · Cited by 9
Zhang, J., Mi, J.-J., & Wang, R. (2023) · World Journal of Gastrointestinal Oncology · doi:10.4251/wjgo.v15.i11.1998 · Cited by 9
“This score was assessed in four parts, comprising patient selection, index test, reference standard, and flow and timing, with the first three parts utilized for applicability assessment[32].”
Montero, J. A., Asfura, O. E. B., Riveros, B. P. P., Burgos, E. L., & Jiménez, M. R. (2023) · International Journal of Colorectal Disease · doi:10.1007/s00384-023-04556-w · Cited by 9
Omar, M., Abu-Salah, R., Agbareia, R., Sharif, Y., Levin, R., Lahat, A., & Sharif, Κ. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1323113 · Cited by 11
Giri, S., Vaidya, A., Agrawal, D., Varghese, J., Patel, R. K., Tripathy, T., Singh, A., & Das, S. (2023) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12375 · Cited by 9
Li, X., Wang, J., Li, P., Zhuang, S., Jiang, S., & Liu, W. (2024) · Medicine · doi:10.1097/md.0000000000036708 · Cited by 9
Couto, H. L., Gargano, L. P., de Oliveira, V. M., Coelho, B. A., Pessoa, E. C., Hassan, A. T., da Silva, A. L., Urban, C. A., Chala, L. F., Sharma, N., et al. (2024) · PharmacoEconomics - Open · doi:10.1007/s41669-023-00470-7 · Cited by 9
“We use the QUADAS-2 tool to assess the risk of bias and the methodological quality of individual studies [62].”
Kang, Y. J., Lee, H. W., Stybayeva, G., & Hwang, S. H. (2024) · Cancers · doi:10.3390/cancers16040751 · Cited by 9
Aly, M. M., Soliman, Y., Elemam, R., Pizones, J., Alzahrani, A., & Elwatidy, S. (2024) · European Spine Journal · doi:10.1007/s00586-023-08087-4 · Cited by 9
Pei, M.-Q., Yang, Y., Zhang, C., Huang, Q., Fang, Y., Xu, L., Lin, S., & He, H. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1353063 · Cited by 9
“We assessed study quality and risk of bias using the Quality Assessment of Diagnostic Accuracy-2 (QUADAS-2) tool (18).”
Reimer, L. J., & Pryce, J. (2024) · Bulletin of the World Health Organization · doi:10.2471/blt.23.290424 · Cited by 9
Zhong, Y., Xiao, Y., Ye, J., Jian, G.-L., & Huang, W. (2024) · BMC Cancer · doi:10.1186/s12885-024-12210-z · Cited by 9
Suartz, C. V., Martinez, L. M., Cordeiro, M., Botelho, L. A. A., Gallutti, F. P., Mota, J. M., Leite, K. R. M., Toren, P., Nahas, W. C., & Ribeiro‐Filho, L. A. (2024) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2024.102087 · Cited by 9
Boujelbane, M. A., Trabelsi, K., Salem, A., Ammar, A., Glenn, J. M., Boukhris, O. F., AlRashid, M. M., Jahrami, H., & Chtourou, H. (2024) · Journal of Alzheimer s Disease · doi:10.3233/jad-240028 · Cited by 14
“…independently assessed the methodological quality of the studies using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [21], chosen for its specialization in diagnostic accuracy studies, which closely aligns with the objectives of our systematic review and…”
Muljadi, R., Koesbandono, K., & Octavius, G. S. (2024) · Pediatric Pulmonology · doi:10.1002/ppul.27044 · Cited by 9
“27 Two reviewers evaluated the scale independently (Gilbert S. Octavius and Koesbandono), and any disagreements were resolved internally and through an expert decision (Rusli Muljadi) until a consensus was reached.”
Accuracy of Smartphone-Based Three-Dimensional Facial Scanning System: A Systematic Review
Luo, Y., Zhao, M., & Lu, J. (2024) · Aesthetic Plastic Surgery · doi:10.1007/s00266-024-04121-y · Cited by 9
“We assessed the quality of the included studies according to the Quality Assessment Tool for Diagnostic Accuracy Studies-2 (QUADAS-2) [35].”
Weimar, Z., Smallwood, N., Shao, J., Chen, X. E., Moran, T. P., & Khor, Y. H. (2024) · Internal Medicine Journal · doi:10.1111/imj.16438 · Cited by 12
“27,28 The Newcastle – Ottawa scale was used according to the study designs, with the standard versions for cohort and case – control studies and an adapted version for cross-sectional studies 29 (Appendix 2).”
Shahab, S. N., van Veen, A., Büchler, A., Saharman, Y. R., Karuniawati, A., Vos, M. D., holt, A. F. V. I. ’., & Severin, J. A. (2024) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-024-00707-1 · Cited by 11
Chorna, O. D., Corsi, G., Secco, S. D., Bancale, A., & Guzzetta, A. (2024) · Children · doi:10.3390/children11060747 · Cited by 13
He, J., Li, S., Wu, X., Chen, X.-H., Yan, D., Wang, X., & Dang, Z.-W. (2024) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-23-385 · Cited by 11
O’Sullivan, N. J., Temperley, H. C., Horan, M. T., Curtain, B. M. M., O’Neill, M. A., Donohoe, C. L., Ravi, N., Corr, A., Meaney, J. F., Reynolds, J. V., et al. (2024) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2024.07.011 · Cited by 9
Parsaei, M., Dashtkoohi, M., Salmani, T. A., Najafi, M. S., Haddadi, M. R., Ghaemi, M., & Hantoushzadeh, S. (2024) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-024-06655-0 · Cited by 10
Kiilgaard, H. C., Nissen, A. H. K., Balaratnasingam, C., Borrelli, E., Breazzano, M. P., van Dijk, E. H. C., Sevik, M. O., Grauslund, J., & Subhi, Y. (2024) · Acta Ophthalmologica · doi:10.1111/aos.16739 · Cited by 9
“Study quality and applicability were evaluated independently by two authors (H.C.K. and A.H.K.N.) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) (Whiting et al., 2011).”
InfluentialZhang, X., Shang, X., Zhang, Y., Li, X., Yang, K., Wang, Y., & Guo, K. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e34569 · Cited by 15
Ultrasonography for confirmation of gastric tube placement
Tsujimoto, Y., Kataoka, Y., Banno, M., Anan, K., Shiroshita, A., & Jujo, S. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012083.pub3 · Cited by 24
Hung, K., Liao, S.-W., Kao, C., Huang, Y., Wu, J., Lin, Y., Lin, C., Lin, C.-H., & Chen, I. (2024) · Diagnostics · doi:10.3390/diagnostics14161769 · Cited by 9
Zhang, W., Wang, Y. J., Yao, Y., Zhang, G. X., Zhang, Y. N., & Gao, S. (2024) · Neurología (English Edition) · doi:10.1016/j.nrleng.2024.07.004 · Cited by 17
Biondi, A., Zabler, N., Kalousios, S., Simblett, S. K., Laiou, P., Viana, P. F., Dümpelmann, M., Schulze‐Bonhage, A., & Richardson, M. P. (2024) · Seizure · doi:10.1016/j.seizure.2024.10.004 · Cited by 15
Claxton, H., Lounis, S. A., Stanton, M., Hall, N. J., & Aldeiri, B. (2024) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2024.162010 · Cited by 9
Lathlean, T. J. H., Ramachandran, A. K., Sim, S., & Whittle, I. R. (2024) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2024.110877 · Cited by 9
“Risk of Bias (ROB) was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool, version 2 (QUADAS-2) [49].”
Bruckhaus, A., Asifriyaz, T., Kriukova, K. K., O'Brien, T. J., Agoston, D. V., Staba, R. J., Jones, N. C., Moshé, S. L., Galanopoulou, A. S., & Duncan, D. (2024) · Epilepsia · doi:10.1111/epi.18131 · Cited by 9
“We deviated from our protocol, which stated that we would use QUADAS2 (Quality Assessment of Diagnostic Accuracy Studies) 20 for risk of bias and quality assessment, and instead opted to use the Newcastle-Ottawa Scale, as it was deemed more appropriate for evaluating both cohort and case–control studies.”
Peng, P., Fu, X., Wang, Y., Zheng, X., Bian, L., Zhati, N., Zhang, S., & Wei, W. (2024) · PLoS ONE · doi:10.1371/journal.pone.0310049 · Cited by 11
Jha, D., Chandran, M., Hong, N., Rhee, Y., Baek, S., Ferguson, S. J., Helgason, B., & Praveen, A. D. (2024) · Journal of Bone Metabolism · doi:10.11005/jbm.24.781 · Cited by 9
“[21] The checklist was updated to carry out a quality assessment within the purview of this review (Supplementary Table 1).”
Prevalence and treatment of perinatal anxiety: diagnostic interview study
Ayers, S., Sinesi, A., Meade, R., Cheyne, H., Maxwell, M., Best, C., McNicol, S., Williams, L. R., Hutton, U. M. Z., Howard, G., et al. (2024) · BJPsych Open · doi:10.1192/bjo.2024.823 · Cited by 9
Boerwinkle, V. L., Nowlen, M. A., Vazquez, J. E., Arhin, M., Reuther, W., Cediel, E. G., McCarty, P. J., Manjón, I., Jubran, J. H., Guest, A., et al. (2024) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2024.1481858 · Cited by 12
Ma, H.-Y., Zhang, R.-J., Zhou, L.-P., Wang, Y.-X., Wang, J.-Q., Shen, C.-L., & Zhang, X.-J. (2024) · European Radiology · doi:10.1007/s00330-024-11292-4 · Cited by 8
“The methodological quality of the included articles was evaluated using the Newcastle-Ottawa Scale (NOS) criteria [17] and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [18] (Supplementary Text 3).”
Jiang, Y., Qi, S., Zhang, R., Zhao, R., Fu, Y., Fang, Y., & Shao, M. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2024.1483521 · Cited by 11
Truenat MTB assays for pulmonary tuberculosis and rifampicin resistance in adults and adolescents
Inbaraj, L. R., Daniel, J., Narayanan, M. K. S., Srinivasalu, V. A., Bhaskar, A., Scandrett, K., Rajendran, P., Kirubakaran, R., Shewade, H. D., Muniyandi, M., et al. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015543.pub2 · Cited by 22
Shafieioun, A., Ghaffari, H., Baradaran, M., Rigi, A., Eftekhar, M. S., Shojaeshafiei, F., Korani, M. A., Hatami, B., Shirdel, S., Ghanbari, K., et al. (2025) · Neurosurgical Review · doi:10.1007/s10143-025-03475-4 · Cited by 9
Breast cancer diagnosis using radiomics-guided DL/ML model-systematic review and meta-analysis
Maruf, N. A., & Basuhail, A. A. (2025) · Frontiers in Computer Science · doi:10.3389/fcomp.2025.1446270 · Cited by 10
Nakamura, E., Mihara, T., Kondo, Y., Noma, H., & Shimizu, S. (2025) · Thrombosis Research · doi:10.1016/j.thromres.2025.109339 · Cited by 9
Tang, X., Zhou, H., Ying, L., Gao, S., & Zhou, Y. (2025) · Science Progress · doi:10.1177/00368504251346906 · Cited by 9
Casenghi, M., Kosack, C., Li, R., Bastard, M., & Ford, N. P. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011155 · Cited by 9
RetractedDiagnostic Criteria for Major Depressive Disorder in Cancer Patients: A Review
Ng, C. G., Sulaiman, A. H., Zainal, N. Z., Boks, M. P., & de Wit, N. J. (2013) · The International Journal of Psychiatry in Medicine · doi:10.2190/pm.45.1.f · Cited by 9
MicroRNA-17 family as novel biomarkers for cancer diagnosis: a meta-analysis based on 19 articles
Gu, R., Huang, S., Huang, W., Li, Y., Liu, H., Yang, L., & Huang, Z. (2015) · Tumor Biology · doi:10.1007/s13277-015-4484-x · Cited by 9
“Four key domains were considered in the QUADAS-2 tool including patient selection, index test, reference standard, and flow and timing [20, 21].”
Li, Y., Yang, L., Sha, K., Liu, T., & Zhang, L. (2016) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2016.10.023 · Cited by 9
Cândia, R., Norero, B., Agüero, C., Díaz, L. A., Ortega, J. P., Wolff, R., Hernández-Rocha, C., Duarte, I., Soza, A., Benítez, C., et al. (2017) · Annals of Hepatology · doi:10.5604/01.3001.0010.2787 · Cited by 9
Fitzpatrick, J. J., Ryan, M. A., & Bruzzi, J. F. (2018) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12723 · Cited by 9
Clinical utility of arterial spin labeling for preoperative grading of glioma
Fu, J., Li, L., Wang, X., Zhang, M., Zhang, Y., & Li, Z. (2018) · Bioscience Reports · doi:10.1042/bsr20180507 · Cited by 9
Instrument-based tests for measuring anterior chamber cells in uveitis: a systematic review protocol
Liu, X., Solebo, A. L., Keane, P. A., Moore, D., & Denniston, A. K. (2019) · Systematic Reviews · doi:10.1186/s13643-019-0946-3 · Cited by 9
Li, W., Xin, C., Zhang, L., Dong, A., Xu, H., & Wu, Y. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.03.016 · Cited by 9
Scioscia, M., Noventa, M., Cavallin, F., Straface, G., Pontrelli, G., Fattizzi, N., Libera, M., Rademacher, T. W., & Robillard, P. (2019) · Journal of Reproductive Immunology · doi:10.1016/j.jri.2019.07.005 · Cited by 9
Lin, T., Shen, Y., Gifford, W., Qin, X., Liu, X., Lan, Y.-T., Chen, K., & Harrison, D. M. (2019) · The American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000358 · Cited by 9
Wang, Q., Lei, D., Yuan, Y., & Zhao, H. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-027144 · Cited by 9
Diagnostic Adjuncts for Oral Cavity Squamous Cell Carcinoma and Oral Potentially Malignant Disorders
Kerr, A. R. (2020) · Textbooks in contemporary dentistry · doi:10.1007/978-3-030-32316-5_9 · Cited by 11
Silva, C. S., Freitas, K. S., Ribeiro, A. P. M. R., Gomes, C. M., & de Bessa, J. (2020) · PeerJ · doi:10.7717/peerj.9039 · Cited by 9
Baccaglini, W. R. C., Glina, F. P. A., Pazeto, C. L., Medina, L. G., Korkes, F., Bernardo, W. M., Sotelo, R. J., Glina, S., Marra, G., Moschini, M., et al. (2020) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2020.06.008 · Cited by 9
Pan, H., Zhou, X., Zhao, F., Chen, H.-Y., & Zhang, Y. (2020) · World Journal of Clinical Cases · doi:10.12998/wjcc.v8.i14.3006 · Cited by 9
Malchi, F., Abedi, P., Jahanfar, S., Talebi, F., Siahkal, S. F., & Zahedian, M. (2020) · Reproductive Sciences · doi:10.1007/s43032-020-00271-x · Cited by 13
Mimoun, C., Benifla, J. L., Fauconnier, A., & Huchon, C. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9092793 · Cited by 10
Blangis, F., Taylor, M., Adamsbaum, C., Devillers, A., Guen, C. G., Launay, E., Bossuyt, P. M., Cohen, J. F., & Chalumeau, M. (2020) · Archives of Disease in Childhood · doi:10.1136/archdischild-2020-319065 · Cited by 13
Self-citationZhou, L., Jiang, Z., Tan, G., & Wang, Z. (2020) · World Neurosurgery · doi:10.1016/j.wneu.2020.12.024 · Cited by 9
Venables, H. K., Wiafe, Y. A., & Adu–Bredu, T. (2020) · Ultrasound · doi:10.1177/1742271x20977051 · Cited by 11
Zhang, Q., Xi, Y., Li, D., Yuan, Z., & Dong, J. (2020) · Annals of Palliative Medicine · doi:10.21037/apm-20-1228 · Cited by 9
Kim, K., & Kim, S. (2021) · Leukemia Research · doi:10.1016/j.leukres.2021.106525 · Cited by 9
Ye, X., Wang, Y., Wang, H., Feng, R., Ye, Z., Han, J., Li, L., Zeng, Z., Chen, M., & Zhang, S. (2021) · Therapeutic Advances in Gastroenterology · doi:10.1177/1756284821994741 · Cited by 10
Cho, S. J., Choi, B. S., Bae, Y. J., Baik, S. H., Sunwoo, L., & Kim, J. H. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.586735 · Cited by 9
Zhang, L., Zhou, Q., Han, Y., Li, P., Ouyang, P.-H., Wang, M.-Y., & Hu, Z.-D. (2021) · Translational Cancer Research · doi:10.21037/tcr-21-104 · Cited by 9
Dynamic and Epidemiology of Lassa Fever Infection in West Africa’s Population from 1969 to 2019
Yessinou, R. E., Kamga-Waladjo, A. R., Noudeke, N. D., Dramou, I., Adinsi, J., Dougnon, V. T., Sangnidjo, E., Osse, R., Dansou, A., & Farougou, S. (2020) · Hosts and Viruses · doi:10.17582/journal.hv/2020/7.6.137.146 · Cited by 10
“Two researchers independently assessed the articles included using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to assess the methodological quality of eligible studies (Whiting et al ., 2011).”
Ahmed, E. A., Almutairi, M. K., & Alkaseb, A. (2021) · Cureus · doi:10.7759/cureus.14925 · Cited by 10
Huo, H., Shen, S., Gao, S., & Ji, B. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00429-w · Cited by 9
Lee, S., Jeong, S. Y., Keun-young Kim, A., & Kim, S. (2021) · Annals of Nuclear Medicine · doi:10.1007/s12149-021-01639-y · Cited by 9
Donohue, C., Carnaby, G., & Garand, K. L. (2021) · American Journal of Speech-Language Pathology · doi:10.1044/2021_ajslp-21-00004 · Cited by 11
Xiong, J., Luo, J., Bian, J., & Wu, J. (2021) · European Radiology · doi:10.1007/s00330-021-08022-5 · Cited by 9
Evaluation of Xpert GBS assay and Xpert GBS LB assay for detection of Streptococcus agalactiae
Han, M., Xie, C., Huang, Q., Wu, Q.-H., Deng, Q.-Y., Xie, T., Liu, Y., Li, Z.-L., Zhong, J., Wang, Y., et al. (2021) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-021-00461-8 · Cited by 11
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.