QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 8,401–8,500 of 14,770
Antunes, M. M., Alves, M., Pinto, F. J., Agnelli, G., & Caldeira, D. (2021) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2021.10.014 · Cited by 9
Drewes, R., Heinze, C., Pech, M., Powerski, M. J., Woidacki, K., Wienke, A., Surov, A., & Omari, J. (2021) · Digestive Diseases · doi:10.1159/000520716 · Cited by 12
Yu, W., Liang, G., Zeng, L., Yang, Y., & Wu, Y. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-051470 · Cited by 9
Choudhury, S., Ghodasara, S., Stiffel, M., Fischer, C. E., Tang‐Wai, D. F., Smith, E. E., Massoud, F., Hsiung, G. R., Lee, L. S., Bruneau, M., et al. (2022) · International Journal of Geriatric Psychiatry · doi:10.1002/gps.5678 · Cited by 9
Wang, K., Lee, E., Kenis, S., Hallam, S. L., Haroon, A., Wan, S., Rabin, N. K., Rojas‐García, A., Padhani, A. R., & Adeleke, S. M. (2022) · European Radiology · doi:10.1007/s00330-021-08311-z · Cited by 9
Hwee, S. E., Htet, N. H., Naing, C. M., Wong, S. T., & Mak, J. W. (2022) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-022-04420-9 · Cited by 9
Urinary biomarkers for the detection of ovarian cancer: a systematic review
Owens, G. L., Barr, C. E., White, H., Njoku, K., & Crosbie, E. J. (2022) · Carcinogenesis · doi:10.1093/carcin/bgac016 · Cited by 9
Meta-analysis of downregulated E-cadherin as a diagnostic biomarker for cervical cancer
Ma, X., Ge, A., Han, J., Kang, J., Zhang, Y., Liu, X., Xing, L., Liu, X., & Dong, L. (2022) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-022-06475-7 · Cited by 10
Hua, T., Zhuo, Z., Duan, Y., Li, X., Gu, H., Haller, S., Zhang, P., Liu, X., Zhang, L., & Liu, Y. (2022) · Neuroradiology · doi:10.1007/s00234-022-02947-4 · Cited by 9
Yao, Y., Lv, W., Xie, X., & Cheng, X. (2019) · Translational Cancer Research · doi:10.21037/tcr.2019.06.33 · Cited by 9
Zhang, C., Chao, F., Wang, S., Han, D., & Chen, G. (2022) · Journal of Oncology · doi:10.1155/2022/1505087 · Cited by 11
Tillmanns, N., Lum, A., Petersen, G. C., Merkaj, S., Verma, T., Zeevi, T., Staib, L. H., Subramanian, H. E., Bahar, R. C., Brim, W. R., et al. (2022) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdac093 · Cited by 9
Pang, N., Gao, J. L., Zhang, N., Guo, M., & Wang, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.1060542 · Cited by 12
Descending pain modulation in irritable bowel syndrome (IBS): a systematic review and meta-analysis
Chakiath, R. J., Siddall, P. J., Kellow, J. E., Hush, J. M., Jones, M. P., Marcuzzi, A., & Wrigley, P. J. (2015) · Systematic Reviews · doi:10.1186/s13643-015-0162-8 · Cited by 11
Diagnostic value of KLK6 as an ovarian cancer biomarker: A meta-analysis
Yang, F., HU, Z.-D., Chen, Y., & Hu, C. (2016) · Biomedical Reports · doi:10.3892/br.2016.662 · Cited by 9
The accuracy of microRNA-210 in diagnosing lung cancer: a systematic review and meta-analysis
Yang, H., Wang, H., Zhang, C., & Tong, Z. (2016) · Oncotarget · doi:10.18632/oncotarget.11446 · Cited by 10
Hunt, H. A., van Kampen, S. C., Takwoingi, Y., Llewellyn, D. J., Pearson, M., & Hyde, C. (2017) · Diagnostic and Prognostic Research · doi:10.1186/s41512-017-0014-1 · Cited by 10
Accuracy of on‐site tests to detect anemia during prenatal care
Sobhy, S., Rogozińska, E., & Khan, K. S. (2017) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12289 · Cited by 9
Xuan, M., Zhou, F., Ding, Y., Zhu, Q., Dong, J., Zhou, H., Cheng, J., Jiang, X. L., & Wu, P. (2017) · Surgical Endoscopy · doi:10.1007/s00464-017-5903-4 · Cited by 9
Manchuelle, A., Pontana, F., de Groote, P., Lebert, P., Fertin, M. J., Baijot, M., Hurt, C. N., Lamblin, N., Debry, N., Schurtz, G., et al. (2018) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2018.04.004 · Cited by 9
Kim, H., Yoon, S. H., Hong, H., Hahn, S., & Goo, J. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-34230-z · Cited by 10
Migda, B., Migda, M., & Migda, M. (2018) · Clinical Radiology · doi:10.1016/j.crad.2018.09.009 · Cited by 9
A systematic review on the use of the breast lesion excision system in breast disease
Sanderink, W. B. G., Laarhuis, B. I., Strobbe, L. J. A., Sechopoulos, I., Bult, P., Karssemeijer, N., & Mann, R. M. (2019) · Insights into Imaging · doi:10.1186/s13244-019-0737-3 · Cited by 9
Yang, Y., Jin, G., Pang, Y., Wang, W., Zhang, H., Tuo, G., Wu, P., Wang, Z., & Zhu, Z. (2020) · Medicine · doi:10.1097/md.0000000000019114 · Cited by 9
Liu, Y., Xie, M., Gao, X., & Liu, R. (2021) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-020-10087-4 · Cited by 9
Non-invasive diagnostic tests for Helicobacter pylori infection
Gurusamy, K. S., Yaghoobi, M., & Davidson, B. R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012080 · Cited by 9
Ankle brachial index for the diagnosis of symptomatic peripheral arterial disease
Crawford, F., Chappell, F. M., Welch, K., Andras, A., & Brittenden, J. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010680 · Cited by 9
The rationale for rating risk of bias should be fully reported
Faggion, C. M. (2016) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2016.03.007 · Cited by 9
Praticare l’appropriatezza in Medicina di Laboratorio. Un aggiornamento
Cappelletti, P. (2016) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-016-0117-7 · Cited by 9
GESTATIONAL DIABETES MELLITUS: Challenges in diagnostics, management and impact
de Wit, L. (2020) · Utrecht University Repository (Utrecht University) · doi:10.33540/195 · Cited by 9
Acute Treatments for Episodic Migraine
Singh, R. B. H., VanderPluym, J. H., Morrow, A. S., Urtecho, M., Nayfeh, T., Roldan, V. D. T., Farah, M. H., Hasan, B., Saadi, S. M., Shah, S. H., et al. (2020) · doi:10.23970/ahrqepccer239 · Cited by 13
Iqbal, Z., Alnuaim, L., Al-Garni, A., Alanzazi, N., AlMukhaylid, S., Qahtani, S. A., Shammas, M. A., Naeem, R. C., Taleb, Y. S., Karrar, T., et al. (2025) · medRxiv · doi:10.1101/2025.07.29.25332402 · Cited by 9
Duggan, S. N., Azharuddin, M., Hernández, R. A., Robertson, C. M., Cooper, D. F., McCall, E. M., Manson, P. N., Virgili, G., Clarke, M. J., Treweek, S. P., et al. (2025) · The Breast · doi:10.1016/j.breast.2025.104668 · Cited by 9
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUA-DAS-2) tool assessed risk of bias in individual studies across four domains: patient selection, index test, reference standard, and flow and timing [13].”
How should we assess trustworthiness of randomized controlled trials?
Wilkinson, J., & Tovey, D. (2025) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2025.111670 · Cited by 8
Pouw, M. A., Calf, A. H., Georg, R. R., de Rooij, S. E., ter Maaten, J. C., & Munster, B. C. V. (2023) · Aging Clinical and Experimental Research · doi:10.1007/s40520-023-02447-2 · Cited by 8
Liu, K., Li, X., Weng, Q., Wang, Y., Wei, J., Zeng, C., Lei, G., & Jiang, T. (2023) · Arthritis Care & Research · doi:10.1002/acr.25205 · Cited by 8
Gustafsson, U., & Hansen, M. (2023) · Mental Health Science · doi:10.1002/mhs2.43 · Cited by 9
Sherriff, N., Mirandola, M., Silva, R., Cordioli, M., Sawyer, A., Gios, L., Zorzi, A., Huber, J., Vera, J. H., Richardson, D., et al. (2024) · BMC Infectious Diseases · doi:10.1186/s12879-024-09019-3 · Cited by 8
Kopatsaris, S., Apostolopoulou, A., Tsakiridis, I. G., Tranidou, A., Zachomitros, F., Papanikolaou, E. G. E., Daponte, A. I., Kalogiannidis, I. A., & Dagklis, T. (2024) · Cancers · doi:10.3390/cancers16061200 · Cited by 9
Datta, D., Selvakumar, B., Goel, A. D., Chhibber, S., Varshney, V. K., & Kumar, R. (2024) · Annals of Nuclear Medicine · doi:10.1007/s12149-024-01934-4 · Cited by 9
Abualsaud, R., Oro, P., Harnegie, M. P., Hockstein, M. A., Tonelli, A. R., & Siuba, M. (2024) · CJC Open · doi:10.1016/j.cjco.2024.05.008 · Cited by 8
“12 Con fl icts were resolved by a third reviewer.”
Oh, D., To, D., Corso, M., Murnaghan, K., Yu, H., & Cancelliere, C. (2024) · Chiropractic & Manual Therapies · doi:10.1186/s12998-024-00542-3 · Cited by 9
Ultrasound diagnostic of intrauterine adhesions: Systematic review and meta‐analysis
Ding, C., Wei, W., Ding, F., Ding, J., Li, B., & Ma, Q. (2024) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.16027 · Cited by 8
Artificial Intelligence as a Tool for Diagnosis of Cardiac Amyloidosis: A Systematic Review
Ahmadi-Hadad, A., Rosa, E. D., Serafino, L. D., & Esposito, G. (2024) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-024-00893-5 · Cited by 8
“Risk of bias was evaluated by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [42].”
Dahdal, J., Jukema, R., Remmelzwaal, S., Raijmakers, P. G. H. M., van der Harst, P., Guglielmo, M., Cramer, M. J., Chamuleau, S. A. J., van Diemen, P. A., Knaapen, P., et al. (2024) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2024.10.014 · Cited by 8
Radiomics-Based Diagnosis in Dentomaxillofacial Radiology: A Systematic Review
Tarakçı, Ö. D., Kış, H. C., Amasya, H., Öztürk, İ., Karahan, E., & Orhan, K. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01307-3 · Cited by 16
Ruksakulpiwat, S., Zhou, W., Phianhasin, L., Benjasirisan, C., Su, T., Aldossary, H. M., Kudlowitz, A., Challa, A. K., Li, J., & Praditukrit, K. (2024) · eNeuro · doi:10.1523/eneuro.0302-24.2024 · Cited by 9
Methodological quality assessment tools for diagnosis and prognosis research: overview and guidance
Kaul, T., Kellerhuis, B. E., Damen, J. A., Schuit, E., Jenniskens, K., van Smeden, M., Reitsma, J. B., Hooft, L., Moons, K. G. M., & Yang, B. (2024) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2024.111609 · Cited by 10
Self-citationA meta-analytic evaluation of the reliability of work-family and family-work conflict scales
Ugwu, L. E., & Idemudia, E. S. (2024) · Scientific Reports · doi:10.1038/s41598-024-83086-z · Cited by 8
Han, X., & Zhang, B. (2025) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2024.2445661 · Cited by 8
“QUADAS-2 scale, a diagnostic test quality evaluation tool [13], was applied to judge the quality of the included literature. the QUADAS-2 scale mainly consists of four parts, which are case selection, trial to be evaluated, gold standard, case flow, and progress. the “Yes”, “No”, or “Unclear”…”
Yu, D., & Chen, C. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2024.1517805 · Cited by 8
“Two researchers independently evaluated the quality of the included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (28).”
Potential diagnostic tools for intensive care unit acquired weakness: A systematic review
Xin, C., Gai, Y., Wei, L. S., Wang, Y., Luo, Y., & Han, B. (2025) · International Journal of Nursing Studies Advances · doi:10.1016/j.ijnsa.2025.100301 · Cited by 8
“The applicability concerns assessment covers three items: (1) patient selection, (2) index test, and (3) reference standard (Whiting et al., 2011).”
Wu, Y., Cheng, Y., Xiao, Y., Shang, H., & Ou, R. (2025) · Journal of Medical Internet Research · doi:10.2196/59649 · Cited by 9
Leone, G., Meli, C., Falsaperla, R., Gullo, F., Licciardello, L., Spina, L. L., Messina, M., Bianco, M. L., Sapuppo, A., Pappalardo, M. G., et al. (2025) · Nutrients · doi:10.3390/nu17040678 · Cited by 8
Afzal, A., Aranan, Y. S., Roberts, T., Covington, J. A., Vidal, L., Ahmed, S., Gill, T. S., & Francis, N. K. (2024) · BJS Open · doi:10.1093/bjsopen/zrae154 · Cited by 9
“Whilst performing MA heterogeneity is computed automatically and is mentioned in this review for descriptive purposes only and the quality of data is mainly assessed by QUADAS-2.”
Weber, M. A., Schnyder, N., Kirschstein, M. A., Graf, M., Endrass, J., & Rossegger, A. (2025) · Swiss Medical Weekly · doi:10.57187/s.3517 · Cited by 9
Reducing risk of bias in interventional studies during their design and conduct: a scoping review
Ren, Z., Webster, A. C., Hunter, K. E., Zhang, J., Yao, Y., Tan, A. G., & Tan, A. (2025) · BMC Medical Research Methodology · doi:10.1186/s12874-025-02467-8 · Cited by 11
Park, B.-M., Kim, S., Choi, J., Song, Y., & Park, S. (2025) · Journal of Clinical Microbiology · doi:10.1128/jcm.01352-24 · Cited by 11
“The quality of the studies was assessed by two independent reviewers (B.M. and S.H.) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool (35).”
Diagnostic Accuracy of Methods Used to Detect Cracked Teeth
Kindaro, V., Molland, H., Shirbegi, S., Renner, P., & Krishnan, U. (2025) · Clinical and Experimental Dental Research · doi:10.1002/cre2.70138 · Cited by 8
Chen, Y., Liao, Y., Li, P., Wei, J., Fang, J., Huang, J., Feng, Y., Xie, C., Li, R., Jin, Q., et al. (2025) · Displays · doi:10.1016/j.displa.2025.103072 · Cited by 8
Digital health tools in juvenile idiopathic arthritis: a systematic literature review
Antón, J., Montoro, M., Loza, E., Otón, T., Ramirez, S., & Benavent, D. (2025) · Pediatric Rheumatology · doi:10.1186/s12969-025-01094-3 · Cited by 8
“…Reviews (AMSTAR2) [18] for SRs, the Jadad score [19] for RCTs, the Newcastle–Ottawa Scale (NOS) [20] for observational studies, the Quality Assessment Diagnostic Accuracy Studies (QUADAS-2) [21] for validation studies, and the method proposed by Hawker and colleagues [22] for qualitative articles.”
Teketelew, B. B., Berta, D. M., Chane, E., Mekuanint, A., Alemayehu, T. T., Mulatie, Z., Walle, M., Angelo, A. A., & Cherie, N. (2025) · PLoS ONE · doi:10.1371/journal.pone.0322382 · Cited by 8
“…based on the aforementioned criteria and assessed methodological quality based on Quality Assessment foe Diagnostic Accuracy Studies 2 (QUADAS 2) quality assessment tool [20], which assess the quality of studies based on the four domain of risk bias and three domain of applicability concern.”
Hyde, E., Anthony, M., Kennedy, S., & Vatish, M. (2025) · Archives of Disease in Childhood · doi:10.1136/archdischild-2025-328523 · Cited by 9
Tomelleri, A., Dejaco, C., Schmidt, W., Falzon, L., Bond, M., Duftner, C., Keen, H. I., Krönke, G., Pineda, C., D’Agostino, M. A., et al. (2025) · RMD Open · doi:10.1136/rmdopen-2025-005738 · Cited by 8
“After applying inclusion and exclusion criteria and excluding duplicates, 21 studies were finally included in the review (see figure 1 for flow chart).”
Parada-Gereda, H. M., Molano-Franco, D., Peña-López, L. A., Pérez-Terán, P., & Masclans, J. R. (2025) · Australian Critical Care · doi:10.1016/j.aucc.2025.101266 · Cited by 9
Prihadi, J. C., Lionardi, S. K., Widjanarko, N. D., Alvianto, S., Rinaldi, F. X., & Iskandar, A. F. (2025) · Journal of Pathology and Translational Medicine · doi:10.4132/jptm.2025.04.16 · Cited by 8
“Included studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [11].”
Termsinsuk, P., Chuncharunee, A., Charatcharoenwitthaya, P., & Pausawasdi, N. (2025) · Digestive Diseases and Sciences · doi:10.1007/s10620-025-09175-9 · Cited by 8
“The quality and risk of bias in included studies were assessed using a modified QUADAS-2 tool [22].”
Deep learning for diagnosing and grading pterygium: A systematic review and meta-analysis
Tiong, E. W. W., Soon, C. Y. S., Ong, Z. Z., Liu, S., Qureshı, R., Rauz, S., & Ting, D. S. J. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110743 · Cited by 10
Jeff, C., Quarton, S., Hatton, C., Parekh, D., THICKETT, D. R., McNally, A., & Sapey, E. (2025) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2025.116995 · Cited by 10
Artificial Intelligence in the Diagnosis of Tongue Cancer: A Systematic Review with Meta-Analysis
Jeong, S.-R., Choi, H.-I., Yang, K.-I., Kim, J.-S., Ryu, J.-W., & Park, H. (2025) · Biomedicines · doi:10.3390/biomedicines13081849 · Cited by 11
“The methodological quality of the 13 included studies was evaluated using the QUADAS-2 tool (Figure 2a,b) [14].”
InfluentialBouillon‐Minois, J., Burlet, C., Lewiss, R. E., Bagheri, R., Perrier, C., Schmidt, J., & Dutheil, F. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00441-5 · Cited by 8
Santos, J. M. M. M., Torri, G. B., da Silva, M. A. M., Monjardim, G. D. F., Mariussi, M., Schmitt, L. G., Wiethan, C. P., Ghezzi, T. L., Ghezzi, C. L. A., Altmayer, S., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11850-4 · Cited by 9
“Two reviewers (G.B.T. and M.S.) independently evaluated the quality of each study included in the analysis using the Quality Assessment of Diagnostic Accuracy Studies, version 2 (QUADAS-2) framework to identify potential sources of bias [10].”
Whole-body magnetic resonance imaging for cutaneous melanoma staging: A scientific review
Russo, A., Marinelli, L., Patanè, V., Alessandrella, M., Pezzella, M., Troiani, T., Brancaccio, G., Scharf, C., Argenziano, G., Cappabianca, S., et al. (2025) · World Journal of Clinical Oncology · doi:10.5306/wjco.v16.i8.109206 · Cited by 8
Pavone, M., Macellari, N., Innocenzi, C., Ciancia, M., Sighinolfi, M. C., Nero, C., Lecointre, L., Moro, F., Costantini, B., Rocco, B., et al. (2025) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2025.110412 · Cited by 8
Davydow, D. S., Brasfield, M., Morrow, C. B., Staffaroni, A. M., Pontone, G. M., & Asken, B. M. (2025) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2025.2429 · Cited by 9
Klokman, V. W., Verhagen, M. J. J., Sanders, M. S., Jellema, K., de Kleijn, D. P. V., & Jie, K. E. (2025) · Otology & Neurotology · doi:10.1097/mao.0000000000004608 · Cited by 9
Critical appraisal of an original research article
Santhanam, S., Ravindran, V. K., & Wincup, C. (2025) · The Journal of the Royal College of Physicians of Edinburgh · doi:10.1177/14782715251369964 · Cited by 9
Dong, X., Li, Y., Hao, J., Zhou, P., Yang, C., Ai, Y., He, M. Y., Zhang, W., & Hu, H. (2025) · BMC Neurology · doi:10.1186/s12883-025-04404-0 · Cited by 11
“The quality of the studies was rigorously assessed by the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [23] and the Methodological Radiomics Quality Score (METRICS) [24].”
2025 Chinese guidelines for the diagnosis and treatment of systemic lupus erythematosus
Zhao, J., Zhang, S., Wang, Q., Tian, X., Chen, Y., Li, M., & Zeng, X. (2025) · Rheumatology and Immunology Research · doi:10.1515/rir-2025-0017 · Cited by 10
“…in 2024 emphasized the challenges systematic reviews, meta-analysis, and network meta-analysis; [24] Cochrane Risk of Bias (ROB) tool for RCTs; [25] Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) for diagnostic studies; [26] Newcastle-Ottawa Scale (NOS) for observational studies.”
Wang, A., Ma, Z., Wang, T., Chen, R., Xi, Y., Wu, Q., Yuan, S., Fan, N., Du, P., & Zang, L. (2025) · Journal of Medical Internet Research · doi:10.2196/77155 · Cited by 8
“The risk of bias and applicability were assessed with the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2), a tool designed to evaluate the quality of primary diagnostic accuracy studies [13].”
Pleural fluid biochemical analyses: a state-of-the-art review
Zheng, W., Porcel, J. M., Lee, G., & Hu, Z.-D. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2577984 · Cited by 12
“QUADAS-2 was used to evaluate the diagnostic test accuracy studies [12].”
Akudjedu, T. N., Ago, J. L., Iweka, E., & Dushimirimana, S. (2025) · Radiography · doi:10.1016/j.radi.2025.103238 · Cited by 12
Mohamed, Y., Kol, S. Q., Stoker, J., & Bipat, S. (2025) · European Radiology · doi:10.1007/s00330-025-12154-3 · Cited by 10
Lee, J.-E., Choi, E., & Park, J. (2025) · BMC Oral Health · doi:10.1186/s12903-025-07171-z · Cited by 9
“First, the majority of included studies relied on retrospective data, which raises the potential for selection bias and limits generalizability [12].”
Cimini, L. A., Pruszczyk, P., Jiménez, D., Weekes, A., Zuin, M., Vanni, S., Ciurzyński, M., Kostrubiec, M., Khemasuwan, D., Yuriditsky, E., et al. (2025) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2025.11.020 · Cited by 11
Gete, K. Y., & Ayele, A. A. (2025) · BMC Neurology · doi:10.1186/s12883-025-04528-3 · Cited by 9
“Methods and reporting follow PRISMA-DTA [12] with QUADAS-2 [13] risk-of-bias assessment; where applicable, we map AI-specific reporting items to CONSORT-AI [14] and CLAIM [15] to enhance transparency and reproducibility.”
Ghatak, T., Pal, A., Rochwerg, B. N., Samanta, S., Kumar, A., Sajjad, S. A., Das, A., & Singh, R. K. (2025) · Journal of Critical Care · doi:10.1016/j.jcrc.2025.155402 · Cited by 9
Lowry, K. P., Jeong, H. E., Kim, K. H., Hughes, K. S., Lee, C. I., Yala, A., Kerlikowske, K. M., & Vachon, C. (2026) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djag002 · Cited by 15
Sirithepmontree, S., Katchamat, N., & Nuampa, S. (2026) · Science Progress · doi:10.1177/00368504251410776 · Cited by 8
“30 This tool is designed for assessing the quality of primary diagnostic accuracy studies in systematic reviews.”
InfluentialAtieh, M. A., Shah, M. S., Hakam, A. E., AlAli, F., AlSayed, S., Tawse‐Smith, A., & Alsabeeha, N. H. M. (2026) · Clinical Oral Implants Research · doi:10.1111/clr.70090 · Cited by 10
“The quality of the included studies was evaluated using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) (Whiting et al. 2011).”
Shi, Y., Wang, C. B., Yang, Y., Li, Q., Chung, P. W., & Wang, Y. (2026) · npj Digital Medicine · doi:10.1038/s41746-025-02320-8 · Cited by 10
“The revised QUADAS-2 tool was used for quality assessment.”
InfluentialLam, Q. T., Minh, L. H. N., Fan, F.-Y., Le, N. Q. K., & Lee, I.-T. (2026) · Diagnostics · doi:10.3390/diagnostics16050731 · Cited by 8
Explainable Artificial Intelligence in Dentistry: A Systematic Review of Its Trust and Translation
Thaweesapphithak, S., Thongchotchat, V., Alinejad-Rokny, H., Samaranayake, L. P., Osathanon, T., & Porntaveetus, T. (2026) · International Dental Journal · doi:10.1016/j.identj.2026.109626 · Cited by 11
“13 PROBAST was used to assess prediction model studies, allowing examination of whether XAI-supported predictions were built upon models with acceptable risk of bias, robustness, and clinical applicability.”
Chest computed tomography as a primary tool in COVID-19 detection: an update meta-analysis
Pang, C., Hou, Q., Yang, Z., & Liwei, R. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00434-z · Cited by 8
Peitsidis, P., Vrachnis, N., Sifakis, S., Katsetos, C., Tsikouras, P. N., Antonakopoulos, N., Alexopoulos, E., & Kalmantis, K. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.10958 · Cited by 8
Borrero, A. M. P., Patiño-Lugo, D. F., Contreras, J. A. P., Velásquez, J. C., & Lugo‐Agudelo, L. H. (2022) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2022.873436 · Cited by 9
Moosa, S., & Dydynsky, R. (2022) · Undergraduate Research in Natural and Clinical Science and Technology (URNCST) Journal · doi:10.26685/urncst.333 · Cited by 8
Huang, P., Yin, X., Huang, Y.-T., Ye, Q.-Q., Chen, S., Cao, X., Xie, T., & Guo, X. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.5.480 · Cited by 8
Circular RNAs as prognostic and diagnostic biomarkers in renal cell carcinoma
Rashedi, S., Mardani, M., Rafati, A., Khavandi, M. M., Mohammadi, F., Javanshir, S., Sarallah, R., Dolatshahi, M., Sabahi, M., Azadnajafabad, S., et al. (2022) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24670 · Cited by 8
Yu, Y., Shi, L., Zhang, H., & Wang, Q. (2022) · Endocrine Connections · doi:10.1530/ec-22-0341 · Cited by 10
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.