Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 483

The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.

Accuracy of Rapid Influenza Diagnostic Tests: A Meta-analysis

Chartrand, Caroline, Leeflang, Mariska M.G., Minion, Jessica, Brewer, Timothy, Pai, Madhukar · 2012 · Annals of Internal Medicine

Abstract

BACKGROUND: Timely diagnosis of influenza can help clinical management. PURPOSE: To examine the accuracy of rapid influenza diagnostic tests (RIDTs) in adults and children with influenza-like illness and evaluate factors associated with higher accuracy. DATA SOURCES: PubMed and EMBASE through December 2011; BIOSIS and Web of Science through March 2010; and citations of articles, guidelines, reviews, and manufacturers. STUDY SELECTION: Studies that compared RIDTs with a reference standard of either reverse transcriptase polymerase chain reaction (first choice) or viral culture. DATA EXTRACTION: Reviewers abstracted study data by using a standardized form and assessed quality by using Quality Assessment of Diagnostic Accuracy Studies criteria. DATA SYNTHESIS: 159 studies evaluated 26 RIDTs, and 35% were conducted during the H1N1 pandemic. Failure to report whether results were assessed in a blinded manner and the basis for patient recruitment were important quality concerns. The pooled sensitivity and specificity were 62.3% (95% CI, 57.9% to 66.6%) and 98.2% (CI, 97.5% to 98.7%), respectively. The positive and negative likelihood ratios were 34.5 (CI, 23.8 to 45.2) and 0.38 (CI, 0.34 to 0.43), respectively. Sensitivity estimates were highly heterogeneous, which was partially explained by lower sensitivity in adults (53.9% [CI, 47.9% to 59.8%]) than in children (66.6% [CI, 61.6% to 71.7%]) and a higher sensitivity for influenza A (64.6% [CI, 59.0% to 70.1%) than for influenza B (52.2% [CI, 45.0% to 59.3%). LIMITATION: Incomplete reporting limited the ability to assess the effect of important factors, such as specimen type and duration of influenza symptoms, on diagnostic accuracy. CONCLUSION: Influenza can be ruled in but not ruled out through the use of RIDTs. Sensitivity varies across populations, but it is higher in children than in adults and for influenza A than for influenza B. PRIMARY FUNDING SOURCE: Canadian Institutes of Health Research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-156-7-201204030-00403

Cites

85 of 85 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 85 references

Cited by

See all 483

Metadata

Authors
Chartrand, C., Leeflang, M. M. G., Minion, J., Brewer, T., & Pai, M.
Venue
Annals of Internal Medicine
Published
2012-04-03
Volume
156
Issue
7
Pages
500-511
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1998407364
Cited by
483
References
85
FWCI
25.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Rapid Influenza Diagnostic Tests: A Meta-analysis. https://app.cochat.ai/papers/10.7326/0003-4819-156-7-201204030-00403
The paper
Chartrand, C., Leeflang, M. M. G., Minion, J., Brewer, T., & Pai, M. (2012). Accuracy of Rapid Influenza Diagnostic Tests: A Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-156-7-201204030-00403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.