A versatile oblique plane microscope for large-scale and high-resolution imaging of subcellular dynamics
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
We present an oblique plane microscope (OPM) that uses a bespoke glass-tipped tertiary objective to improve the resolution, field of view, and usability over previous variants. Owing to its high numerical aperture optics, this microscope achieves lateral and axial resolutions that are comparable to the square illumination mode of lattice light-sheet microscopy, but in a user friendly and versatile format. Given this performance, we demonstrate high-resolution imaging of clathrin-mediated endocytosis, vimentin, the endoplasmic reticulum, membrane dynamics, and Natural Killer-mediated cytotoxicity. Furthermore, we image biological phenomena that would be otherwise challenging or impossible to perform in a traditional light-sheet microscope geometry, including cell migration through confined spaces within a microfluidic device, subcellular photoactivation of Rac1, diffusion of cytoplasmic rheological tracers at a volumetric rate of 14 Hz, and large field of view imaging of neurons, developing embryos, and centimeter-scale tissue sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The NumPy Array: A Structure for Efficient Numerical Computation
van der Walt, S., Colbert, S. C., & Varoquaux, G. (2011) · Computing in Science & Engineering · doi:10.1109/mcse.2011.37 · Cited by 9,381 · cited 3×
“Using Numpy and Numba libraries in Python (van der Walt et al., 2011), data was split into tiles that fit in local memory, flat-fielded, orthogonally interpolated to deskew the stage scan (Maioli, 2017), saved as a BigDataViewer H5 file (Pietzsch et al., 2015), and stitched using default settings in BigStitcher (Hörl…”
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611 · cited 1×
“For rotation into the traditional epi-fluorescence-like orientation, the freely available IMOD software package was used (Kremer et al., 1996).”
Spatially resolved, highly multiplexed RNA profiling in single cells
Chen, K. H., Boettiger, A. N., Moffitt, J. R., Wang, S., & Zhuang, X. (2015) · Science · doi:10.1126/science.aaa6090 · Cited by 2,969 · cited 1×
“…our approach is fully compatible with automated fluid exchange, which is increasingly important for projects like the Human Cell Atlas that necessitate iterative imaging approaches for spatial -omics of RNAs and proteins at the single cell level throughout entire tissues (Chen et al., 2015).”
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355 · cited 1×
“Light-sheet fluorescence microscopy (LSFM) first generated significant interest in the biological community as a result of its ability to image developing embryos with single-cell resolution, inherent optical sectioning, low phototoxicity and high temporal resolution (Huisken et al., 2004).”
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334 · cited 1×
“Prior to the first casting, each master mold was vapor deposition silanized with Trichloro (1H, 1H, 2H, 2H-perfluorooctyl) silane (448931, Sigma-Aldrich) in a vacuum desiccator (Scienceware, SigmaAldrich) to create an anti-stiction layer for PDMS demolding as previously described (Qin et al., 2010).”
Robust single-particle tracking in live-cell time-lapse sequences
Jaqaman, K., Loerke, D., Mettlen, M., Kuwata, H., Grinstein, S., Schmid, S. L., & Danuser, G. (2008) · Nature Methods · doi:10.1038/nmeth.1237 · Cited by 1,970
Lattice light-sheet microscopy: Imaging molecules to embryos at high spatiotemporal resolution
Chen, B.-C., Legant, W. R., Wang, K., Shao, L., Milkie, D. E., Davidson, M. W., Janetopoulos, C., Wu, X. S., Hammer, J. A., Liu, Z., et al. (2014) · Science · doi:10.1126/science.1257998 · Cited by 1,919
Wolf, K., te Lindert, M., Krause, M., Alexander, S., te Riet, J., Willis, A. L., Hoffman, R. M., Figdor, C. G., Weiss, S. J., & Friedl, P. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201210152 · Cited by 1,375
Noise2Void - Learning Denoising From Single Noisy Images
Krull, A., Buchholz, T.-O., & Jug, F. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00223 · Cited by 1,366
Nuclear envelope rupture and repair during cancer cell migration
Denais, C. M., Gilbert, R. M., Isermann, P., McGregor, A. L., te Lindert, M., Weigelin, B., Davidson, P. M., Friedl, P., Wolf, K., & Lammerding, J. (2016) · Science · doi:10.1126/science.aad7297 · Cited by 1,318
Cited by
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Self-citationDynamin is primed at endocytic sites for ultrafast endocytosis
Imoto, Y., Raychaudhuri, S., Fenske, P., Sandoval, E., Itoh, K., Blumrich, E.-M., Mamer, L., Zarebidaki, F., Söhl-Kielczynski, B., Trimbuch, T., et al. (2021) · doi:10.1101/2021.02.15.431332 · Cited by 109
A guidebook for DISCO tissue clearing
Molbay, M., Kolabas, Z. I., Todorov, M. I., Ohn, T., & Ertürk, A. (2021) · Molecular Systems Biology · doi:10.15252/msb.20209807 · Cited by 96
“So far, LSFM is a growing field in microscopy and novel designs such as ctASLM (Chakraborty et al, 2019) or oblique plane microscopy (Sapoznik et al, 2020) substantially improve the resolution in xy and z, making the overall resolution better and more homogeneous.”
MethodMembrane compression by synaptic vesicle exocytosis triggers ultrafast endocytosis
Ogunmowo, T. H., Jing, H., Raychaudhuri, S., Kusick, G. F., Imoto, Y., Li, S., Itoh, K., Ma, Y., Jafri, H., Dalva, M. B., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38595-2 · Cited by 53
“…Poisson noise, and then decon-voluted twice using the built-in deconvblind function: the fi rst point spread function (PSF) input is measured from nonspeci fi c antibody signal in the STED images, and the second PSF input is chosen as the returned PSF from the fi rst run of blind deconvolution 96 .”
Mantis: High-throughput 4D imaging and analysis of the molecular and physical architecture of cells
Ivanov, I. E., Hirata-Miyasaki, E., Chandler, T., Cheloor-Kovilakam, R., Liu, Z., Pradeep, S., Liu, C., Bhave, M., Khadka, S., Arias, C., et al. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae323 · Cited by 21
Metadata
- Authors
- Sapoznik, E., Chang, B.-J., Huh, J., Ju, R. J., Azarova, E. V., Pohlkamp, T., Welf, E. S., Broadbent, D., Carisey, A. F., Stehbens, S. J., Lee, K.-M., Marín, A., Hanker, A. B., Schmidt, J. C., Arteaga, C. L., Yang, B., Kobayashi, Y., Tata, P. R., Kruithoff, R., Doubrovinski, K., Shepherd, D. P., Millett-Sikking, A., York, A. G., Dean, K. M., & Fiolka, R. P.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2020-11-12
- Volume
- 9
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W3105390201
- Cited by
- 196
- References
- 79
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.