Implant-Associated Infections: A Review of the Safety of Cardiac Implants
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cardiac implantations are among the most critical, and life-saving patient management procedures. Most cardiac implantations are performed to correct abnormalities in the conduction and the rhythm of the heart. Because the implants are intended for long-term use ranging from months to years, the failure of an implant is considered a major setback both in the patients as well as surgeons' perspectives. Implant failures can have multifactorial reasons, amongst which infectious causes need to be adequately addressed. This review attempts to evaluate the nature of implants, etiology, predisposing factors, infection control, and preventive strategies for cardiac implant-associated infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Biofilms significantly contribute to persistent infections as they attach to organic (tissues and teeth) and inorganic surfaces (such as medical implants and catheters) [31,32].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [32]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial biofilm and associated infections
Jamal, M., Ahmad, W., Andleeb, S., Jalil, F., Imran, M., Nawaz, M. A., Hussain, T., Ali, M., Rafiq, M., & Kamil, M. A. (2018) · Journal of the Chinese Medical Association · doi:10.1016/j.jcma.2017.07.012 · Cited by 1,642
The Consequences of Biofilm Dispersal on the Host
Fleming, D., & Rumbaugh, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-29121-2 · Cited by 186
Research works printed but not linked: 40
- Chung SH, Kim WB. Various approaches and treatments for pelvic organ prolapse in women. J Menopausal Med. 2018, 24:155-162. 10.6118/jmm.2018.24.3.155 · DOI
- Jones HG, Rees M, Aboumarzouk OM, et al.. Prosthetic mesh placement for the prevention of parastomal herniation. Cochrane Database Syst Rev. 2018, 7:CD008905. 10.1002/14651858.CD008905.pub3 · DOI
- Rav Acha M, Soifer E, Hasin T. Cardiac implantable electronic miniaturized and micro devices. Micromachines (Basel). 2020, 11:902. 10.3390/mi11100902 · DOI
- Al-Jumaili A, Kumar A, Bazaka K, Jacob MV. Electrically insulating plasma polymer/ZnO composite films. Materials (Basel). 2019, 12:3099. 10.3390/ma12193099 · DOI
- Weinstein RA, Darouiche RO. Device-associated infections: a macroproblem that starts with microadherence. Clin Infect Dis. 2001, 33:1567-1572. 10.1086/323130 · DOI · Paper page
- Cardiac implantable electronic devices (CIEDs). J Arrhythm. 2019, 35.328-472. 10.1002/joa3.12273 · doi:10.1002/joa3.12273
- Portillo ME, Corvec S, Borens O, Trampuz A. Propionibacterium acnes: an underestimated pathogen in implant-associated infections. Biomed Res Int. 2013, 2013:804391. 10.1155/2013/804391 · DOI
- Zimmerli W, Sendi P. Pathogenesis of implant-associated infection: the role of the host. Semin Immunopathol. 2011, 33:295-306. 10.1007/s00281-011-0275-7 · DOI · Paper page
- Kandi V. Biofilm production correlating with multidrug resistance among clinical isolates of Acinetobacter baumannii. J Clin Diagn Res. 2015, 9:DJ02. 10.7860/JCDR/2015/13069.6084 · doi:10.7860/jcdr/2015/13069.6084
- Darouiche RO, Landon GC, Patti GM, et al.. Role of Staphylococcus aureus surface adhesins in orthopaedic device infections: are results model-dependent?. J Med Microbiol. 1997, 46:75-79. 10.1099/00222615-46-1-75 · DOI
- Mobley HLT, Chippendale GR, Tenney JH, Mayrer AR, Crisp LJ, Penner JL, Warren JW. MR/K hemagglutinin of Providencia stuartii correlates with adherence to catheters and with persistence in catheter-associated bacteriuria. J Infect Dis. 1988, 157:264-271. 10.1093/infdis/157.2.264 · DOI
- Preda VG, Săndulescu O. Communication is the key: biofilms, quorum sensing, formation and prevention. Discoveries (Craiova). 2019, 7:e100. 10.15190/d.2019.13 · DOI · Paper page
- Aryana A, Keifer T, Bhaskar R, Bowers MR, O'Neill PG, Brewer Z. Acute spontaneous erosion of the right ventricle by an infected but chronically stable defibrillator lead manifesting as cardiac tamponade. HeartRhythm Case Rep. 2020, 6:875-878. 10.1016/j.hrcr.2020.09.001 · doi:10.1016/j.hrcr.2020.09.001
- Wagner C, Hänsch GM. Pathophysiologie der implantatassoziierten Infektion: vom Biofilm zur Osteolyse und septischen Lockerung [Pathophysiology of implant-associated infections: from biofilm to osteolysis and septic loosening]. [Article in German]. Orthopade. 2015, 44:967-973. 10.1007/s00132-015-3183-z · DOI
- Zhang JL, Zou H, Wang HW, et al.. Incidence, bacterial spectrum and predictive risk factors for stent associated respiratory tract infection. [Article in Chinese]. Zhonghua Jie He He Hu Xi Za Zhi. 2016, 39:368-371. 10.3760/cma.j.issn.1001-0939.2016.05.007 · doi:10.3760/cma.j.issn.1001-0939.2016.05.007
- Falcone M, Tiseo G, Durante-Mangoni E, et al.. Risk factors and outcomes of endocarditis due to non-HACEK gram-negative bacilli: data from the prospective multicenter Italian endocarditis study cohort. Antimicrob Agents Chemother. 2018, 62:e02208-17. 10.1128/AAC.02208-17 · DOI
- Shah H, Mehmood M, Salahudin M, Altaf A. Risk factor for cardiac permanent pacemaker infection. J Nepal Health Res Counc. 2019, 17:158-162. 10.33314/jnhrc.v0i0.1272 · doi:10.33314/jnhrc.v0i0.1272
- Khairy TF, Lupien MA, Nava S, et al.. Infections associated with resterilized pacemakers and defibrillators. N Engl J Med. 2020, 382:1823-1831. 10.1056/NEJMoa1813876 · DOI
- Venkataramana V. Small colony variants and their clinical significance. Ann Trop Med Public Health. 2016, 9:137-139. 10.4103/1755-6783.177406 · DOI
- Kandi V. Bacterial capsule, colony morphology, functions, and its relation to virulence and diagnosis. Ann Trop Med Public Health. 2015, 8:151-153. 10.4103/1755-6783.162409 · DOI
- Boev C, Kiss E. Hospital-acquired infections: current trends and prevention. Crit Care Nurs Clin North Am. 2017, 29:51-65. 10.1016/j.cnc.2016.09.012 · DOI
- Imai K. Perioperative management for the prevention of bacterial infection in cardiac implantable electronic device placement. J Arrhythm. 2016, 32:283-286. 10.1016/j.joa.2015.06.007 · DOI
- Birnie DH, Wang J, Alings M, et al.. Risk factors for infections involving cardiac implanted electronic devices. J Am Coll Cardiol. 2019, 74:2845-2854. 10.1016/j.jacc.2019.09.060 · DOI · Paper page
- Tattevin P, Flécher E, Auffret V, et al.. Risk factors and prognostic impact of left ventricular assist device-associated infections. Am Heart J. 2019, 214:69-76. 10.1016/j.ahj.2019.04.021 · DOI
- Polyzos KA, Konstantelias AA, Falagas ME. Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis. Europace. 2015, 17:767-777. 10.1093/europace/euv053 · DOI · Paper page
- Philip A. Iatrogenic microperforation linked to hemorrhagic pericardial effusion complicated by cardiac tamponade. Cureus. 2020, 12:e9023. 10.7759/cureus.9023 · doi:10.7759/cureus.9023
- Khalid M, Murtaza G, Ayub MT, Ramu V, Paul T. Right ventricle perforation post pacemaker insertion complicated with cardiac tamponade. Cureus. 2018, 10:e2266. 10.7759/cureus.2266 · doi:10.7759/cureus.2266
- Song J, Tark A, Larson EL. The relationship between pocket hematoma and risk of wound infection among patients with a cardiovascular implantable electronic device: an integrative review. Heart Lung. 2020, 49:92-98. 10.1016/j.hrtlng.2019.09.009 · DOI
- Carrión-Camacho MR, Marín-León I, Molina-Doñoro JM, González-López JR. Safety of permanent pacemaker implantation: a prospective study. J Clin Med. 2019, 8:35. 10.3390/jcm8010035 · DOI
- Kuehl R, Brunetto PS, Woischnig AK, et al.. Preventing implant-associated infections by silver coating. Antimicrob Agents Chemother. 2016, 60:2467-2475. 10.1128/AAC.02934-15 · DOI
- Howell C, Grinthal A, Sunny S, Aizenberg M, Aizenberg J. Designing liquid-infused surfaces for medical applications: a review. Adv Mater. 2018, 30:e1802724. 10.1002/adma.201802724 · DOI · Paper page
- Blomström-Lundqvist C, Traykov V, Erba PA, et al.. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Europace. 2020, 22:515-549. 10.1093/europace/euz246 · DOI · Paper page
- Khalil M, Karimzad K, Durand JB, Malek AE, Raad II, Viola GM. Prevention of cardiac implantable electronic device-related infection in patients with cancer: the role of a comprehensive prophylactic bundle approach that includes the antimicrobial mesh. Open Forum Infect Dis. 2020, 7:ofaa433. 10.1093/ofid/ofaa433 · DOI
- Tarakji KG, Mittal S, Kennergren C, et al.. Antibacterial envelope to prevent cardiac implantable device infection. N Engl J Med. 2019, 380:1895-1905. 10.1056/NEJMoa1901111 · DOI · Paper page
- Kabulski GM, Northup A, Wiggins BS. Postoperative antibiotic prophylaxis following cardiac implantable electronic device placement. J Innov Card Rhythm Manag. 2019, 10:3777-3784. 10.19102/icrm.2019.100804 · DOI
- Döring M, Richter S, Hindricks G. The diagnosis and treatment of pacemaker-associated infection. Dtsch Arztebl Int. 2018, 115:445-452. 10.3238/arztebl.2018.0445 · DOI
- Arnold CJ, Chu VH. Cardiovascular implantable electronic device infections. Infect Dis Clin North Am. 2018, 32:811-825. 10.1016/j.idc.2018.06.004 · DOI
- Olsen T, Jørgensen OD, Nielsen JC, Thøgersen AM, Philbert BT, Johansen JB. Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982-2018). Eur Heart J. 2019, 40:1862-1869. 10.1093/eurheartj/ehz316 · DOI · Paper page
- Palraj BR, Farid S, Sohail MR. Strategies to prevent infections associated with cardiovascular implantable electronic devices. Expert Rev Med Devices. 2017, 14:371-381. 10.1080/17434440.2017.1322506 · DOI
- Polewczyk A, Jacheć W, Polewczyk AM, Tomasik A, Janion M, Kutarski A. Infectious complications in patients with cardiac implantable electronic devices: risk factors, prevention, and prognosis. Pol Arch Intern Med. 2017, 127:597-607. 10.20452/pamw.4065 · doi:10.20452/pamw.4065
Cited by
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
Sahoo, J., Sarkhel, S., Mukherjee, N., & Jaiswal, A. (2022) · ACS Omega · doi:10.1021/acsomega.2c06211 · Cited by 185
Lima, M., Teixeira-Santos, R., Gomes, L. C., Faria, S. I., Valcarcel, J., Vázquez, J. A., Cerqueira, M. A., Pastrana, L., Bourbon, A. I., & Mergulhão, F. J. (2021) · Molecules · doi:10.3390/molecules26144378 · Cited by 30
Metadata
- Authors
- Kandi, V., & Vadakedath, S.
- Venue
- Cureus
- Published
- 2020-12-25
- ISSN
- 2168-8184
- Cited by
- 10
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant-Associated Infections: A Review of the Safety of Cardiac Implants. https://app.cochat.ai/papers/10.7759/cureus.12267
- The paper
- Kandi, V., & Vadakedath, S. (2020). Implant-Associated Infections: A Review of the Safety of Cardiac Implants. Cureus. https://doi.org/10.7759/cureus.12267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.