Using Portable Transducers to Measure Tremor Severity
Open accessThe DOI matches its DataCite record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Background: Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. Methods: Medline was searched via PubMed.gov in December 2015 using the Boolean expression “tremor AND (accelerometer OR accelerometry OR gyroscope OR inertial measurement unit OR digitizing tablet OR transducer).” Abstracts of 419 papers dating back to 1964 were reviewed for relevant portable transducers and methods of tremor analysis, and 105 papers written in English were reviewed in detail. Results: Accelerometers, gyroscopes, and digitizing tablets are used most commonly, but few are sold for the purpose of measuring tremor. Consequently, most software for tremor analysis is developed by the user. Wearable transducers are capable of recording tremor continuously, in the absence of a clinician. Tremor amplitude, frequency, and occurrence (percentage of time with tremor) can be computed. Tremor amplitude and occurrence correlate strongly with clinical ratings of tremor severity. Discussion: Transducers provide measurements of tremor amplitude that are objective, precise, and valid, but the precision and accuracy of transducers are mitigated by natural variability in tremor amplitude. This variability is so great that the minimum detectable change in amplitude, exceeding random variability, is comparable for scales and transducers. Research is needed to determine the feasibility of detecting smaller change using averaged data from continuous long-term recordings with wearable transducers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“ET shows a frequency between 4 and 12 Hz; its variable amplitude depends on factors such as anxiety, limb position, voluntary activity and disease duration20.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [18]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“Most accelerometers are piezoelectric, piezoresistive, or capacitive devices and have been incorporated into a variety of wearable devices.(22,23) Capacitive MEMS accelerometers are now used most commonly in human motion analysis.”
BackgroundMeasurement of Angular Acceleration of a Rigid Body Using Linear Accelerometers
Padgaonkar, A. J., Krieger, K. W., & King, A. I. (1975) · Journal of Applied Mechanics · doi:10.1115/1.3423640 · Cited by 590
ActiGraph and Actical Physical Activity Monitors: A Peek under the Hood
JOHN, D., & FREEDSON, P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399f5e · Cited by 353
Re-emergent tremor of Parkinson's disease
Jankovic, J., Schwartz, K. S., & Ondo, W. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.67.5.646 · Cited by 307
Clinically deployable Kinesia™ technology for automated tremor assessment
Giuffrida, J. P., Riley, D. E., Maddux, B. N., & Heldman, D. A. (2009) · Movement Disorders · doi:10.1002/mds.22445 · Cited by 251
Physiologic and essential tremor
Elble, R. J. (1986) · Neurology · doi:10.1212/wnl.36.2.225 · Cited by 231
Self-citation
Research works printed but not linked: 4
- [15]Bendat JS Piersol AG Random data: analysis and measurement procedures 4th ed Hoboken, NJ Wiley 2010
- [26]Bancroft JB Lachapelle G Estimating MEMS gyroscope G-sensitivity errors in foot mounted navigation 2nd International Conference on Ubiquitous Positioning, Indoor Navigation and Location-Based Service Helsinki IEEE 2012 1 6 http://plan.geomatics.ucalgary.ca/papers/upinlbs%202012_bancroft%202020etal_oct202012.pdf
- [42]Welch PD On the relationship between batch means, overlapping batch means, and spectral estimation Thesen A Grant H Kelton WD Proceedings of the 1987 Winter Simulation Conference New York ACM 1987 320 323
- [52]Elble R Zesiewicz T Fahn-Tolosa-Marin tremor scale and digitizing tablet have comparable minimum detectable change Mov Disord 2015 30 S558 PMC5618112 28966878
Cited by
Items 101–121 of 121
Clinical Classification of Tremor Syndromes
Becktepe, J. S., & Deuschl, G. (2022) · Oxford University Press eBooks · doi:10.1093/med/9780197529652.003.0002
Elble, R. J. (2022) · Oxford University Press eBooks · doi:10.1093/med/9780197529652.003.0009
Self-citationFajardo, J., & de Melo, L. F. (2023) · Brazilian Journal of Health Review · doi:10.34119/bjhrv6n4-252
ดัดพันธ์, ณ., พิทยศิริ, ร., & จิตรกฤษฎากุล, อ. (2017) · Chula Digiverse · doi:10.58837/chula.the.2017.1613
Viability of the Essential Leg Tremor Monitoring Device
Maheswaran, B., Eyler, E., & Song, Y. (2024) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--40427
Digital Health, Smartphone-Based Motor Assessment, and Public Health
Souza, G. D. S., Furtado, B. K. A., Almeida, E. B., Callegari, B., & Pinheiro, M. D. C. N. (2024) · Advances in medical technologies and clinical practice book series · doi:10.4018/979-8-3693-0851-6.ch003
Modelling and Simulation of a Vertically Integrated Nano Generator in Vibration Mode
Paul, K. A. D. P. S., & Adikary, S. U. (2025) · Proceedings in Technology Transfer · doi:10.1007/978-981-96-1399-1_20
Egorchev, A. A., Chickrin, D. E., Pashin, D. M., & Фердинандович, Ф. А. (2024) · Computational nanotechnology · doi:10.33693/2313-223x-2024-11-4-87-93
(2025) · Frontiers Media SA eBooks · doi:10.3389/978-2-8325-6551-3
Examination of hyperkinetic movement disorders
Panyakaew, P., Carandang, R. A., & Bhidayasiri, R. (2025) · International review of movement disorders · doi:10.1016/bs.irmvd.2025.09.006
Rurak, B. K. (2021) · Murdoch University Research Portal
Video-based diagnosis and classification of tremor with artificial intelligence
Rönn, A.-J. (2025) · Online Publication Service of Würzburg University (Würzburg University) · doi:10.25972/opus-42969
Diagnostic procedure in a patient with tremor
Hollý, P. (2026) · Neurologie pro praxi · doi:10.36290/neu.2025.076
Mondragón-González, S. L. (2019) · theses.fr (ABES) · doi:10.70675/e78705daz18a9z4695zac41zadeb07ee7c37
Rujirussawarawong, S., Ounmuang, C., Aungsumart, S., Kasemsuk, C., & Limotai, N. (2026) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70707
External validation of an open access tool for tremor analysis "Tremoroton"
Kocbek, S. (2026) · Repository of the University of Ljubljana (University of Ljubljana)
Butler, R. D. (2024) · University of Minnesota Digital Conservancy (University of Minnesota)
Ekinci, A. S., Gündoğan, S., Tanrıverdi, Z., Arıcı, Ş., & Seçıl, Y. (2026) · Acta Neurologica Belgica · doi:10.1007/s13760-026-03209-3
Gauthier-Lafreniere, E., Aljassar, M., Rymar, V. V., Milton, J., & Sadikot, A. F. (2022) · doi:10.3389/fninf.2022.878279.s001
Clinical neurophysiology studies in the diagnosis of movement disorders
GRIPPE, T., Callister, M. N., VIAL, F., Merchant, S., & Chen, R. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-27442-8.00011-1
Metadata
- Authors
- Elble, R., & McNames, J.
- Affiliations
- SIU Medicine (US)
- Portland State University (US)
- Venue
- Tremor and Other Hyperkinetic Movements
- Publisher
- Tremor and Other Hyperkinetic Movements
- Published
- 2016-05-17
- Volume
- 6
- Pages
- 375-375
- PMC
- PMC4872171
- OpenAlex
- W2402999595
- Cited by
- 43
- References
- 41
- Citations by year
- 2025: 1 · 2024: 10 · 2023: 8 · 2022: 8 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- cc-by-nc-nd
- Locations
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PDXScholar (Portland State University) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Columbia Academic Commons (Columbia University)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- tremor severity, accelerometer, gyroscope, inertial measurement unit, digitizing tablet, wearable sensors, tremor amplitude, tremor frequency, minimal detectable change
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.