Using Portable Transducers to Measure Tremor Severity
Open accessThe DOI matches its DataCite record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Background: Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. Methods: Medline was searched via PubMed.gov in December 2015 using the Boolean expression “tremor AND (accelerometer OR accelerometry OR gyroscope OR inertial measurement unit OR digitizing tablet OR transducer).” Abstracts of 419 papers dating back to 1964 were reviewed for relevant portable transducers and methods of tremor analysis, and 105 papers written in English were reviewed in detail. Results: Accelerometers, gyroscopes, and digitizing tablets are used most commonly, but few are sold for the purpose of measuring tremor. Consequently, most software for tremor analysis is developed by the user. Wearable transducers are capable of recording tremor continuously, in the absence of a clinician. Tremor amplitude, frequency, and occurrence (percentage of time with tremor) can be computed. Tremor amplitude and occurrence correlate strongly with clinical ratings of tremor severity. Discussion: Transducers provide measurements of tremor amplitude that are objective, precise, and valid, but the precision and accuracy of transducers are mitigated by natural variability in tremor amplitude. This variability is so great that the minimum detectable change in amplitude, exceeding random variability, is comparable for scales and transducers. Research is needed to determine the feasibility of detecting smaller change using averaged data from continuous long-term recordings with wearable transducers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“ET shows a frequency between 4 and 12 Hz; its variable amplitude depends on factors such as anxiety, limb position, voluntary activity and disease duration20.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [18]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“Most accelerometers are piezoelectric, piezoresistive, or capacitive devices and have been incorporated into a variety of wearable devices.(22,23) Capacitive MEMS accelerometers are now used most commonly in human motion analysis.”
BackgroundMeasurement of Angular Acceleration of a Rigid Body Using Linear Accelerometers
Padgaonkar, A. J., Krieger, K. W., & King, A. I. (1975) · Journal of Applied Mechanics · doi:10.1115/1.3423640 · Cited by 590
ActiGraph and Actical Physical Activity Monitors: A Peek under the Hood
JOHN, D., & FREEDSON, P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399f5e · Cited by 353
Re-emergent tremor of Parkinson's disease
Jankovic, J., Schwartz, K. S., & Ondo, W. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.67.5.646 · Cited by 307
Clinically deployable Kinesia™ technology for automated tremor assessment
Giuffrida, J. P., Riley, D. E., Maddux, B. N., & Heldman, D. A. (2009) · Movement Disorders · doi:10.1002/mds.22445 · Cited by 251
Physiologic and essential tremor
Elble, R. J. (1986) · Neurology · doi:10.1212/wnl.36.2.225 · Cited by 231
Self-citation
Research works printed but not linked: 4
- [15]Bendat JS Piersol AG Random data: analysis and measurement procedures 4th ed Hoboken, NJ Wiley 2010
- [26]Bancroft JB Lachapelle G Estimating MEMS gyroscope G-sensitivity errors in foot mounted navigation 2nd International Conference on Ubiquitous Positioning, Indoor Navigation and Location-Based Service Helsinki IEEE 2012 1 6 http://plan.geomatics.ucalgary.ca/papers/upinlbs%202012_bancroft%202020etal_oct202012.pdf
- [42]Welch PD On the relationship between batch means, overlapping batch means, and spectral estimation Thesen A Grant H Kelton WD Proceedings of the 1987 Winter Simulation Conference New York ACM 1987 320 323
- [52]Elble R Zesiewicz T Fahn-Tolosa-Marin tremor scale and digitizing tablet have comparable minimum detectable change Mov Disord 2015 30 S558 PMC5618112 28966878
Cited by
Monje, M. H. G., Foffani, G., Obeso, J. A., & Sánchez‐Ferro, Á. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121036 · Cited by 143
Channa, A., Popescu, N., & Ciobanu, V. (2020) · Sensors · doi:10.3390/s20092713 · Cited by 130
Dopamine-responsive and dopamine-resistant resting tremor in Parkinson disease
Zach, H., Dirkx, M. F., von Roth, D., Pasman, J. W., Bloem, B. R., & Helmich, R. C. G. (2020) · Neurology · doi:10.1212/wnl.0000000000010316 · Cited by 127
Kim, H. B., Lee, W. W., Kim, A., Lee, H. J., Park, H. Y., Jeon, H. S., Kim, S. K., Jeon, B., & Park, K. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.02.007 · Cited by 124
The clinical and electrophysiological investigation of tremor
Deuschl, G., Becktepe, J. S., Dirkx, M. F., Haubenberger, D., Hassan, A., Helmich, R. C. G., Muthuraman, M., Panyakaew, P., Schwingenschuh, P., Zeuner, K. E., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.01.004 · Cited by 122
Self-citationClinical Assessments in Parkinson's Disease
Bhidayasiri, R., & Martínez‐Martín, P. (2017) · International review of neurobiology · doi:10.1016/bs.irn.2017.01.001 · Cited by 121
How to do an electrophysiological study of tremor
Vial, F., Kassavetis, P., Merchant, S. H. I., Haubenberger, D., & Hallett, M. (2019) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2019.06.002 · Cited by 114
The Essential Tremor Rating Assessment Scale
Swartling, C. (2016) · Journal of Neurology and Neuromedicine · doi:10.29245/2572.942x/2016/4.1038 · Cited by 102
Ondo, W. G., Hashem, V. I., LeWitt, P. A., Pahwa, R., Shih, L. C., Tarsy, D., Zesiewicz, T., & Elble, R. J. (2017) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.12560 · Cited by 101
Self-citationWearable Devices for Assessment of Tremor
Vescio, B., Quattrone, A., Nisticò, R., Crasà, M., & Quattrone, A. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.680011 · Cited by 81
Evaluation of movement and brain activity
Hallett, M., DelRosso, L. M., Elble, R. J., Ferri, R., Horak, F. B., Lehericy, S., Mancini, M., Matsuhashi, M., Matsumoto, R., Muthuraman, M., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.04.023 · Cited by 72
Self-citationTechnologies and applications in wireless biosensors for real-time health monitoring
Xu, Z., Hao, Y., Luo, A., & Jiang, Y. (2024) · Med-X · doi:10.1007/s44258-024-00041-3 · Cited by 69
Wearable sensors and features for diagnosis of neurodegenerative diseases: A systematic review
Zhao, H., Cao, J., Xie, J., Liao, W., Lei, Y., Cao, H., Qu, Q., & Bowen, C. (2023) · Digital Health · doi:10.1177/20552076231173569 · Cited by 56
Accuracy of Smartphone Video for Contactless Measurement of Hand Tremor Frequency
Williams, S., Fang, H., Relton, S. D., Wong, D., Alam, T., & Alty, J. (2020) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.13119 · Cited by 54
Validation and application of computer vision algorithms for video-based tremor analysis
Friedrich, M. U., Roenn, A.-J., Palmisano, C., Alty, J., Paschen, S., Deuschl, G., Ip, C. W., Volkmann, J., Muthuraman, M., Peach, R. L., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01153-1 · Cited by 52
Noninvasive modulation of essential tremor with focused ultrasonic waves
Riis, T. S., Losser, A. J., Kassavetis, P., Moretti, P. M., & Kubanek, J. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad27ef · Cited by 50
Machine Learning in Tremor Analysis: Critique and Directions
De, A., Bhatia, K. P., Volkmann, J., Peach, R. L., & Schreglmann, S. R. (2023) · Movement Disorders · doi:10.1002/mds.29376 · Cited by 47
Tremor rating scales and laboratory tools for assessing tremor
Elble, R. J., & Ondo, W. G. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120202 · Cited by 47
Self-citationBleier, N., Mubarik, M. H., Rasheed, F., Aghassi‐Hagmann, J., Tahoori, M. B., & Kumar, R. (2020) · Proceedings - International Symposium on Computer Architecture/Proceedings · doi:10.1109/isca45697.2020.00028 · Cited by 42
Hand-Tremor Frequency Estimation in Videos
Pintea, S. L., Zheng, J., Li, X., Bank, P. J. M., van Hilten, J. J., & van Gemert, J. C. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-11024-6_14 · Cited by 41
Quantifying Tremor in Essential Tremor Using Inertial Sensors—Validation of an Algorithm
McGurrin, P. M., McNames, J., Wu, T., Hallett, M., & Haubenberger, D. (2020) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2020.3032924 · Cited by 41
Self-citationLópez-Blanco, R., Velasco, M. A., Méndez-Guerrero, A., Romero, J. P., del Castillo, M. D., Serrano, J. I., Benito-León, J., Bermejo-Pareja, F., & Rocon, E. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.02.015 · Cited by 40
Are smartphones and machine learning enough to diagnose tremor?
Balachandar, A., Algarni, M., de Oliveira, L. M., Marsili, L., Merola, A., Sturchio, A., Espay, A. J., Hutchison, W. D., Balasubramaniam, A., Rudzicz, F., et al. (2022) · Journal of Neurology · doi:10.1007/s00415-022-11293-7 · Cited by 39
Non-invasive electrical stimulation of peripheral nerves for the management of tremor
Valdunciel, A. P., Rajagopal, A., Pons, J. L., & Delp, S. L. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120195 · Cited by 38
The patient's perspective: The effect of levodopa on Parkinson symptoms
Zach, H., Dirkx, M. F., Pasman, J. W., Bloem, B. R., & Helmich, R. C. G. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2016.11.015 · Cited by 37
Wearable sensors during drawing tasks to measure the severity of essential tremor
Ali, S. M., Arjunan, S. P., Peters, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08922-6 · Cited by 35
Adapted Feeding Utensils for People With Parkinson's-Related or Essential Tremor
Sabari, J., Stefanov, D. G., Chan, J., Goed, L., & Starr, J. (2019) · American Journal of Occupational Therapy · doi:10.5014/ajot.2019.030759 · Cited by 35
A Movement-Tremors Recorder for Patients of Neurodegenerative Diseases
Gugliandolo, G., Campobello, G., Capra, P. P., Marino, S., Bramanti, A., Lorenzo, G. D., & Donato, N. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2900141 · Cited by 34
Estimating Change in Tremor Amplitude Using Clinical Ratings: Recommendations for Clinical Trials
Elble, R. J. (2018) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.455 · Cited by 31
Self-citationFlexiCores: low footprint, high yield, field reprogrammable flexible microprocessors
Bleier, N., Lee, C., Rodríguez, F. J., Sou, A., White, S., & Kumar, R. (2022) · Proceedings - International Symposium on Computer Architecture/Proceedings · doi:10.1145/3470496.3527410 · Cited by 28
Smartphone Apps Provide a Simple, Accurate Bedside Screening Tool for Orthostatic Tremor
Bhatti, D., Thompson, R., Hellman, A. M., Penke, C., Bertoni, J. M., & Torres‐Russotto, D. R. (2017) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.12547 · Cited by 27
Frequency response of the leap motion controller and its suitability for measuring tremor
Kincaid, C. J., Vaterlaus, A. C., Stanford, N. R., & Charles, S. K. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.11.001 · Cited by 25
Tang, L., Hu, Q., Wang, X., Liu, L., Zheng, H., Yu, W., Luo, N., Liu, J., & Song, C. (2024) · Scientific Reports · doi:10.1038/s41598-024-79111-w · Cited by 24
Increasing the use of mobile technology–derived endpoints in clinical trials
Herrington, W. G., Goldsack, J. C., & Landray, M. (2018) · Clinical Trials · doi:10.1177/1740774518755393 · Cited by 24
Prediction of Pathological Tremor Signals Using Long Short-Term Memory Neural Networks
Valdunciel, A. P., Lopo-Martínez, V., Sendra-Arranz, R., González-Sánchez, M., Sánchez, J. R. P., Grandas, F., Torricelli, D., Moreno, J. C., Barroso, F. O., Pons, J. L., et al. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3209316 · Cited by 23
Accelerometric Classification of Resting and Postural Tremor Amplitude
van der Linden, C., Berger, T., Brandt, G. A., Strelow, J. N., Jergas, H., Baldermann, J. C., Visser-Vandewalle, V. E. R. M., Fink, G. R., Barbe, M. T., Petry‐Schmelzer, J. N., et al. (2023) · Sensors · doi:10.3390/s23208621 · Cited by 23
Quantification of tremor severity with a mobile tremor pen
Zajki-Zechmeister, T., Kögl, M., Kerstin, K., Franthal, S., Homayoon, N., Katschnig, P., Wenzel, K., Laszlo, Z.-Z., & Schwingenschuh, P. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e04702 · Cited by 23
Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor
Ali, S. M., Arjunan, S. P., Peter, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2023.3329344 · Cited by 22
The role of laboratory investigations in the classification of tremors
Angelini, L., Terranova, R., Lazzeri, G., van den Berg, K. R. E., Dirkx, M. F., & Paparella, G. (2023) · Neurological Sciences · doi:10.1007/s10072-023-07108-w · Cited by 22
Gauthier-Lafrenière, E., Aljassar, M., Rymar, V. V., MILTON, J. G., & Sadikot, A. F. (2022) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.878279 · Cited by 22
Assessment of Botulinum Neurotoxin Injection for Dystonic Hand Tremor: A Randomized Clinical Trial
Rajan, R., Srivastava, A. K., Anandapadmanabhan, R., Saini, A., Upadhyay, A., Gupta, A., Vishnu, V. Y., Pandit, A. K., Vibha, D., Singh, M. B., et al. (2020) · JAMA Neurology · doi:10.1001/jamaneurol.2020.4766 · Cited by 20
Remote measurement and home monitoring of tremor
Mari, Z. K., & Haubenberger, D. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120201 · Cited by 17
Elble, R. J., & Ellenbogen, A. (2017) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.344 · Cited by 16
Self-citationElectrophysiology in Functional Movement Disorders: An Update
Kamble, N. L., & Pal, P. K. (2023) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.793 · Cited by 15
Quantitative assessment of Parkinsonian tremor by using biosensor device
Marino, S., Cartella, E., Donato, N., Muscarà, N., Sorbera, C., Cimino, V., Salvo, S. D., Micchìa, K., Silvestri, G., Bramanti, A., et al. (2019) · Medicine · doi:10.1097/md.0000000000017897 · Cited by 15
Wearable Peripheral Electrical Stimulation Devices for the Reduction of Essential Tremor: A Review
Karamesinis, A. D., Sillitoe, R. V., & Kouzani, A. Z. (2021) · IEEE Access · doi:10.1109/access.2021.3084819 · Cited by 14
Krishna, R., Pathirana, P. N., Horne, M. K., Szmulewicz, D. J., & Corben, L. A. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3124869 · Cited by 13
Valdunciel, A. P., Lopo-Martínez, V., Beltrán-Carrero, A. J., Sendra-Arranz, R., González-Sánchez, M., Sánchez, J. R. P., Grandas, F., Farina, D., Pons, J. L., Barroso, F. O., et al. (2023) · Entropy · doi:10.3390/e25010114 · Cited by 12
The Rehapiano—Detecting, Measuring, and Analyzing Action Tremor Using Strain Gauges
Ferenčík, N., Jaščur, M., Bundzel, M., & Cavallo, F. (2020) · Sensors · doi:10.3390/s20030663 · Cited by 11
Validity of tremor analysis using smartphone compatible computer vision frameworks
Wolke, R., Welzel, J., Maetzler, W., Deuschl, G., & Becktepe, J. S. (2025) · Scientific Reports · doi:10.1038/s41598-025-97252-4 · Cited by 10
Biswas, S., & Gogoi, A. K. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.11.001 · Cited by 10
Samotus, O., Lee, J., & Jog, M. (2021) · Toxins · doi:10.3390/toxins13040264 · Cited by 10
Defining the Rhythm: Developing a New Method to Describe Tremor and Myoclonus
Latorre, A., Hale, B., Cordivari, C., Humaidan, K., Rothwell, J. C., Bhatia, K. P., & Rocchi, L. (2025) · Movement Disorders · doi:10.1002/mds.70034 · Cited by 9
Lamotrigine Induces Tremor among Epilepsy Patients Probably via Cerebellar Pathways
Kovács, A., Farkas, Z., Kelemen, A., Juhos, V., Szűcs, A., & Kamondi, A. (2019) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.248.273 · Cited by 9
Herbal medicine treatments for essential tremor: A retrospective chart review study
Kang, A.-R., Moon, S., Cho, S., Park, S.-U., Jung, W., Park, J.-M., Ko, C.-N., Cho, K.-H., & Kwon, S. (2019) · Journal of Herbal Medicine · doi:10.1016/j.hermed.2019.100295 · Cited by 9
An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings
Longardner, K., Shen, Q., Tang, B. H., Wright, B. A., Kundu, P., & Nahab, F. B. (2024) · Digital Biomarkers · doi:10.1159/000539529 · Cited by 8
Tracking motion kinematics and tremor with intrinsic oscillatory property of instrumental mechanics
Ni, C., Lin, Y., Lu, L., Wang, J., Liu, W., Kuo, S., & Pan, M. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10432 · Cited by 8
Bedside clinical assessment of patients with common upper limb tremor and algorithmic approach
Panyakaew, P., Phuenpathom, W., Bhidayasiri, R., & Hallett, M. (2024) · Asian Biomedicine · doi:10.2478/abm-2024-0008 · Cited by 7
Quantitative Assessment of Cerebella Ataxia, through Automated Limb-Coordination tests
Krishna, R., Pathirana, P. N., Horne, M. K., Power, L., & Szmulewicz, D. J. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856694 · Cited by 7
Xue, X., Moon, S., Ganesh, V., Cai, Q., Chu, Y., Schropp, E., Roque, D., Garcia, T. P., Sharma, N., & Jiang, X. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3654713 · Cited by 6
Amarantini, D., Rieu, I., Castelnovo, G., Fluchère, F., Laurencin, C., Degos, B., Poujois, A., Kreisler, A., Sangla, S., Tir, M., et al. (2022) · Sensors · doi:10.3390/s22062385 · Cited by 6
Slow Orthostatic Tremor and the Case for Routine Electrophysiological Evaluation of All Tremors
Torres‐Russotto, D. R., & Elble, R. J. (2019) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.499 · Cited by 6
Self-citationImpact of clinical neurophysiological assessment on diagnosis and management of tremor disorders
Longardner, K., Satpathy, Y., Litvan, I., & Haubenberger, D. (2025) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2025.05.003 · Cited by 5
Tremor Phenomenology and Pathophysiology
Elble, R. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95702-1.00136-6 · Cited by 5
Self-citationTremor quantification through event-based movement trajectory modeling
Dimitrakopoulos, K., Ellmer, C., Lindstrcom, M., & Medvedev, A. V. (2017) · IEEE Conference on Control Technology and Applications (CCTA) · doi:10.1109/ccta.2017.8062518 · Cited by 5
Development of a smart glove for affordable diagnosis of stroke-driven upper extremity paresis
Dutta, D., Sen, S., Aruchamy, S., & Mandal, S. (2020) · International Conference on Computer, Electrical & Communication Engineering (ICCECE) · doi:10.1109/iccece48148.2020.9223073 · Cited by 5
Differentiating Postural and Kinetic Tremor Responses to Deep Brain Stimulation in Essential Tremor
Butler, R. D., Brinda, A. K., Blumenfeld, M., Bryants, M. N., Grund, P. M., Pandey, S. R., Cornish, C. K. S., Sullivan, D., Krieg, J. D. S., Umoh, M., et al. (2024) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.14256 · Cited by 4
Detection of Tremor Associated with Rest and Effort Activity Using Machine Learning
Aljihmani, L., Kerdjidj, O., Zhu, Y., Mehta, R. K., & Qaraqe, K. A. (2020) · International Conference Automatics and Informatics (ICAI) · doi:10.1109/icai50593.2020.9311368 · Cited by 4
Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform
Fajardo, J., & de Melo, L. F. (2023) · Sensors · doi:10.3390/s23229020 · Cited by 4
Tremor after solid organ transplantation: Results from the TransplantLines Biobank and Cohort Study
van der Stouwe, A. M. M., Riemersma³, N. L., Knobbe, T. J., Kremer, D., Nolte, S., Plasmeijer, D. B., Neto, A. W. G., Bakker, S. J. L., Drost, G., Elting, J. W. J., et al. (2024) · European Journal of Neurology · doi:10.1111/ene.16412 · Cited by 4
Myorhythmia: A Quantitative Study of Synchrony and Rhythmicity Between the Head and Upper Limbs
Elkhooly, M., Elkouzi, A., & Elble, R. J. (2025) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.986 · Cited by 4
Self-citationTremor quantification through data-driven nonlinear system modeling
Medvedev, A. V., Olsson, F., & Wigren, T. (2017) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2017.8264559 · Cited by 4
Features of Physiological Tremor in Diabetic Patients
Aljihmani, L., Abbas, H. T., Zhu, Y., Mehta, R. K., Sasangohar, F., Erraguntla, M., Lawley, M., Abbasi, Q. H., & Qaraqe, K. A. (2019) · IEEE International Smart Cities Conference (ISC2) · doi:10.1109/isc246665.2019.9071646 · Cited by 4
Reis, C., He, S., Pogosyan, A. H., Haliasos, N., Low, H. L., Misbahuddin, A., Aziz, T. Z., FitzGerald, J. J., Green, A. L., Denison, T., et al. (2022) · medRxiv · doi:10.1101/2022.06.16.22276451 · Cited by 4
Assessment of Tremor Severity in Patients with Essential Tremor Using Smartwatches
Velasco, M. A., Blanco, R. L., Muñoz, J. P. R., Sobrino, M. D. D. C., Serrano, J. I., León, J. B., & Rocón, E. (2020) · Jornadas de Automática · doi:10.17979/spudc.9788497497749.0347 · Cited by 3
Belinskiy, A. V., Михайлович, Д. В., Черноризов, А. М., & Lobin, M. (2023) · Российский психологический журнал · doi:10.21702/rpj.2023.2.1 · Cited by 3
Jabarkheel, Z., & Shukla, A. W. (2024) · Dystonia · doi:10.3389/dyst.2024.12551 · Cited by 3
Modern Phenomenology of Tremor: How Novel Technology Can Assist in the Diagnosis of Tremor
Panyakaew, P., & Carandang, R. (2025) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70241 · Cited by 3
Coleman, J. A. C., Sarasua, S. M., Boccuto, L., Moore, H. W., Skinner, S. A., & DeLuca, J. M. (2021) · Nursing Open · doi:10.1002/nop2.840 · Cited by 3
Smid, A., Dominguez‐Vega, Z. T., van Laar, T., Oterdoom, D. L. M., Absalom, A. R., van Egmond, M. E., Drost, G., & van Dijk, J. M. C. (2024) · Neurosurgical Review · doi:10.1007/s10143-024-02312-4 · Cited by 3
Quantitative Evaluation of Parkinsonian Tremor and the Impact on it by DBS and Drugs
Meka, S. S. L., Kandadai, R. M., & Borgohain, R. (2022) · IEEE International Students' Conference on Electrical, Electronics and Computer Science (SCEECS) · doi:10.1109/sceecs54111.2022.9741006 · Cited by 3
Analysis of 3D spatial trajectories in Parkinsonian, essential and physiological tremors
Jombík, P., Spodniak, P., Bahýľ, V., & Necpál, J. (2017) · Journal of Neural Transmission · doi:10.1007/s00702-017-1835-3 · Cited by 3
Sensor-based data-driven differentiation between Parkinson’s tremor and essential tremor
Sil, T., Selzam, V., Peach, R. L., Tamás, G., Deuschl, G., Schreglmann, S. R., Volkmann, J., Reich, M. M., & Muthuraman, M. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.130336 · Cited by 2
Zhu, N., & Miller, N. S. (2020) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4047815 · Cited by 2
Kaburagi, M., Maki, F., Hino, S., Nakano, M., Yamaguchi, T., Takasaki, M., Iwamuro, H., Iijima, K., Sasanuma, J., Watanabe, K., et al. (2023) · Neurology International · doi:10.3390/neurolint15040091 · Cited by 2
Assessing Tremor: Diagnostic Pearls, Rating Scales, and Waveform Recording
LeWitt, P. A., Fasano, A. A., & Espay, A. J. (2022) · Oxford University Press eBooks · doi:10.1093/med/9780197529652.003.0018 · Cited by 1
Elble, R. J. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_5 · Cited by 1
Self-citationSmart Glove for Tremor Detection
Reddy, A. S., Khan, S., Ravali, P., & Prasad, K. (2023) · Advances in engineering research/Advances in Engineering Research · doi:10.2991/978-94-6463-252-1_14 · Cited by 1
Characteristics of accelerometric activity of the head in healthy subjects at rest and in postures
Kovács, A., Hejczei, L., Váraljai, C., Abrantes, M., Györfi, O., & Kamondi, A. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2112429 · Cited by 1
Does Cup-Grip Type Affect Tremor among People with Essential Tremor?
Roth, N., & Rosenblum, S. (2021) · Sensors · doi:10.3390/s21237797 · Cited by 1
Neurophysiological Features of Tremor during Walking in Parkinson's Disease
Costanzo, M., Marchet, F., Leodori, G., Cutrona, C., Bartolo, M. I. D., Vivacqua, G., Conte, A., Fabbrini, G., Berardelli, A., & Belvisi, D. (2024) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.14293 · Cited by 1
GYROSCOPIC STABILIZATION FOR UNIAXIAL HAND TREMORS
Wehse, A. S., Muse, D., & Sun, I. (2019) · Digital WPI · Cited by 1
Hand-tremor frequency estimation in videosPreprint
Pintea, S. L., Zheng, J., Li, X., Bank, P. J. M., van Hilten, J. J., & van Gemert, J. C. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.03218 · Cited by 1
Nuevas tecnologías para la evaluación objetiva y la asistencia de pacientes con temblor esencial
Blanco, R. L. (2020) · Docta Complutense (Universidad Complutense de Madrid) · Cited by 1
Martelleto, M. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2019.tde-26082021-192025 · Cited by 1
\nParkinson’s tremor: effects of dopamine and cognitive load
Zach, H. (2023) · Radboud Repository (Radboud University) · Cited by 1
Distribution of Essential Tremor in the Degrees of Freedom of the Upper Limb
Pigg, A. C. (2017) · ScholarsArchive (Brigham Young University)
Involuntary Tremor Analysis based on the Accelerometric Measurements
Borik, Š., Valjaskova, B., Šmondrk, M., Babušiak, B., & Bednár, T. (2019) · International Conference on Measurement (MEASUREMENT) · doi:10.23919/measurement47340.2019.8779958
Appel, V. C. R. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.18.2019.tde-09052024-154644
Hand-tremor Frequency Estimation in Videos
Zheng, J. (. (2018) · Research Repository (Delft University of Technology)
Metadata
- Authors
- Elble, R., & McNames, J.
- Affiliations
- SIU Medicine (US)
- Portland State University (US)
- Venue
- Tremor and Other Hyperkinetic Movements
- Publisher
- Tremor and Other Hyperkinetic Movements
- Published
- 2016-05-17
- Volume
- 6
- Pages
- 375-375
- PMC
- PMC4872171
- OpenAlex
- W2402999595
- Cited by
- 43
- References
- 41
- Citations by year
- 2025: 1 · 2024: 10 · 2023: 8 · 2022: 8 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- cc-by-nc-nd
- Locations
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PDXScholar (Portland State University) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Columbia Academic Commons (Columbia University)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- tremor severity, accelerometer, gyroscope, inertial measurement unit, digitizing tablet, wearable sensors, tremor amplitude, tremor frequency, minimal detectable change
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.