The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis
Open accessAbstract
OBJECTIVE: To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. METHODS: Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple clinical sites worldwide. The experiment measured their ability to detect the direction of motion of a high-contrast moving bar on a flatscreen monitor in 3 conditions: with the prosthesis system on and a 1-to-1 mapping of spatial information, with the system off, and with the system on but with randomly scrambled spatial information. RESULTS: Fifteen subjects (54%) were able to perform the task significantly better with their prosthesis system than they were with their residual vision, 2 subjects had significantly better performance with their residual vision, and no difference was found for 11 subjects. Of the 15 better-performing subjects, 11 were available for follow-up testing, and 10 of them had significantly better performance with normal rather than with scrambled spatial information. CONCLUSIONS: This work demonstrates that blind subjects implanted with the Argus II retinal prosthesis were able to perform a motion detection task they could not do with their native vision, confirming that electrical stimulation of the retina provides spatial information from synchronized activation of multiple electrodes. TRIAL REGISTRATION: clinicaltrials.gov Identifier:NCT00407602
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their performance also improved for object localization and motion discrimination tasks (Ahuja et al. 2011; Barry, Dagnelie, and Argus II Study Group 2012; Dorn et al. 2013; Dagnelie et al. 2017).”
From Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only (2022) · cites this paper as Dorn et al. 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationVisual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 480
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Köhler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Visual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa
Yanai, D., Weiland, J. D., Mahadevappa, M., Greenberg, R. J., Fine, I., & Humayun, M. S. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.027 · Cited by 233
Self-citationRoessler, G. F., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B. A. E., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Rizzo, J. F., Wyatt, J. L., Humayun, M. S., de Juan, E., Liu, W., Chow, A. Y., Eckmiller, R., Zrenner, E., Yagi, T., & Abrams, G. W. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00430-9 · Cited by 152
Feasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149
Self-citation
Cited by
Sorted by citations
Items 101–101 of 101
Explainable Machine Learning Predictions of Perceptual Sensitivity for Retinal Prostheses
Pogoncheff, G., Hu, Z., Rokem, A., & Beyeler, M. (2023) · doi:10.1101/2023.02.09.23285633 · Cited by 9
“, age at blindness diagnosis, age at implant surgery) from previous studies [3], [11], [12].”
Metadata
- Authors
- Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T.
- Affiliations
- Second Sight Medical Products (US)
- University of Southern California (US)
- Corresponding author
- Dorn, Jessy D.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2013-02-01
- Volume
- 131
- Issue
- 2
- Pages
- 183
- ISSN
- 2168-6165 (ISSN-L)
- PMC
- PMC3924899
- OpenAlex
- W2024323852
- Cited by
- 177
- References
- 12
- Citations by year
- 2026: 10 · 2025: 8 · 2024: 5 · 2023: 3 · 2022: 7 · 2021: 16 · 2020: 16 · 2019: 14 · 2018: 16 · 2017: 17 · 2016: 22 · 2015: 13 · 2014: 20 · 2013: 9
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- JAMA Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- National Eye Institute (R24EY012893, EY012893, R01EY012893, R01EY021220)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Keywords
- Argus II, retinal prosthesis, motion direction detection, retinitis pigmentosa, blindness, spatial mapping, visual prosthesis
- MeSH terms
- Adult, Aged, Blindness, Electrodes, Implanted, Electric Stimulation Therapy, Feasibility Studies, Female, Humans, Male, Microelectrodes, Middle Aged, Motion Perception, Perceptual Disorders, Retina, Retinitis Pigmentosa, Sensory Thresholds, Treatment Outcome, Prosthesis Implantation, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review