The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Influence of Triple-Lumen Central Venous Catheters Coated With Chlorhexidine and Silver Sulfadiazine on the Incidence of Catheter-Related Bacteremia
Abstract
OBJECTIVE: To evaluate the efficacy of triple-lumen central venous catheters coated with a combination product of chlorhexidine and silver sulfadiazine (CSS) in reducing the incidence of local catheter infection and catheter-related bacteremia. DESIGN: Randomized, controlled trial. SETTING: The surgical intensive care units in a university hospital. PATIENTS: All patients who needed central venous catheterization were randomized to receive either an uncoated triple-lumen catheter (n = 157) or a catheter coated with CSS (n = 151). MAIN OUTCOME MEASURE: Catheters were removed when no longer needed or suspected as a cause of infection. The tip and a 5-cm segment of the intradermal portion of the catheter were cultured semiquantitatively. Blood cultures were obtained when clinically indicated. The remaining segment of catheters coated with CSS were cut and incubated on an agar plate with strains of Staphylococcus aureus and Enterococcus. Zone of inhibition was determined 24 hours later. Data were analyzed by survival and logistic multivariate regression methods. RESULTS: Catheters coated with CSS were effective in reducing the rate of significant bacterial growth on either the tip or intradermal segment (40%) compared with control catheters (52%; P = .04). However, there was no difference in the incidence of catheter-related bacteremia (3.8% [uncoated] vs 3.3% [coated]; P = .81). In vitro activity of catheters with CSS against S aureus was evident up to 25 days but activity against Enterococcus dissipated more quickly over time and was absent by day 4. The most common colonizing organisms were coagulase-negative staphylococcus and enterococcus. Variables that were associated with a significant amount of growth on the tip or intradermal segment were a duration of catheterization of longer than 7 days, jugular insertion site, and the absence of a CSS coating. The use of a guidewire when the catheter was removed was associated with a lower risk of significant bacterial growth. CONCLUSIONS: The use of CSS reduces the incidence of significant bacterial growth on either the tip or intradermal segments of coated triple-lumen catheters but has no effect on the incidence of catheter-related bacteremia. In this patient population, catheters coated with CSS provide no additional benefit over uncoated catheters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., Marts, K., Mansfield, P. F., & Bodey, G. P. (1994) · Infection Control & Hospital Epidemiology · doi:10.1086/646902 · Cited by 774
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
(1996) · American Journal of Infection Control · doi:10.1016/s0196-6553(96)90058-9 · Cited by 492
Liñares, J., Sitges-Serra, A., Garau, J., Pérez, J. L., & Martín, R. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.21.3.357-360.1985 · Cited by 474
Mermel, L. A., McCormick, R. D., Springman, S. R., & Maki, D. G. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90369-9 · Cited by 441
A Controlled Trial of Scheduled Replacement of Central Venous and Pulmonary-Artery Catheters
Cobb, D. K., High, K. P., Sawyer, R. G., Sable, C. A., Adams, R. B., Lindley, D. A., Pruett, T. L., Schwenzer, K. J., & Farr, B. M. (1992) · New England Journal of Medicine · doi:10.1056/nejm199210083271505 · Cited by 438
Maki, D. G., Cobb, L., Garman, J. K., Shapiro, J. M., Ringer, M., & Helgerson, R. B. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90579-7 · Cited by 412
Sherertz, R. J., Raad, I. I., Belani, A., Koo, L. C., Rand, K. H., Pickett, D. L., Straub, S. A., & Fauerbach, L. L. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.1.76-82.1990 · Cited by 381
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationPreventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Dental biofilms: difficult therapeutic targets
SOCRANSKY, S. S., & HAFFAJEE, A. D. (2002) · Periodontology 2000 · doi:10.1034/j.1600-0757.2002.280102.x · Cited by 1,273
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Self-citationPrevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
A Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400101 · Cited by 804
Self-citationGuidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Self-citationPratt, R. J., Pellowe, C. M., Wilson, J. A., Loveday, H. P., Harper, P. J., Jones, S. R. L. J., McDougall, C., & Wilcox, M. H. (2007) · Journal of Hospital Infection · doi:10.1016/s0195-6701(07)60002-4 · Cited by 725
Karakitsos, D., Labropoulos, N., De Groot, E., Patrianakos, A. P., Kouraklis, G., Poularas, J., Samonis, G., Tsoutsos, D. A., Konstadoulakis, M. M., & Karabinis, A. (2006) · Critical Care · doi:10.1186/cc5101 · Cited by 639
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Veenstra, D. L., Saint, S., Saha, S., Lumley, T., & Sullivan, S. D. (1999) · JAMA · doi:10.1001/jama.281.3.261 · Cited by 571
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Self-citationDonovan, J., Little, P., Mills, N., Smith, M., Brindle, L., Jacoby, A., Peters, T., Frankel, S., Neal, D., & Hamdy, F. (2002) · BMJ · doi:10.1136/bmj.325.7367.766 · Cited by 533
Intravascular catheter-related infections: advances in diagnosis, prevention, and management
Raad, I., Hanna, H., & Maki, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70235-9 · Cited by 525
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Infections Associated with Medical Devices: Pathogenesis, Management and Prophylaxis
von Eiff, C., Jansen, B., Kohnen, W., & Becker, K. (2005) · Drugs · doi:10.2165/00003495-200565020-00003 · Cited by 459
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Clinical Infectious Diseases · doi:10.1086/344188 · Cited by 440
Self-citationEggimann, P., & Pittet, D. (2001) · Chest · doi:10.1378/chest.120.6.2059 · Cited by 395
Central venous catheter use: Part 1: Mechanical complications
Polderman, K. H., & Girbes, A. R. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1154-9 · Cited by 377
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Self-citationLorente, L., Henry, C., Martín, M. M., Jiménez, A., & Mora, M. L. (2005) · Critical Care · doi:10.1186/cc3824 · Cited by 307
Veenstra, D. L. (1999) · JAMA · doi:10.1001/jama.282.6.554 · Cited by 299
Central venous catheterization
Taylor, R. W., & Palagiri, A. V. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260241.80346.1b · Cited by 299
Crnich, C. J., & Maki, D. G. (2002) · Clinical Infectious Diseases · doi:10.1086/339863 · Cited by 264
SAFDAR, N., KLUGER, D. M., & MAKI, D. G. (2002) · Medicine · doi:10.1097/00005792-200211000-00007 · Cited by 261
Rijnders, B. J., Peetermans, W. E., Verwaest, C., Wilmer, A., & Wijngaerden, E. V. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2212-x · Cited by 141
Metadata
- Authors
- Heard, S. O., Wagle, M., Vijayakumar, E., McLean, S., Brueggemann, A., Napolitano, L. M., Edwards, L. P., O'Connell, F. M., Puyana, J. C., & Doern, G. V.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1998-01-12
- Volume
- 158
- Issue
- 1
- Pages
- 81
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2057567574
- Cited by
- 473
- References
- 28
- FWCI
- 34.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.