The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Open accessAbstract
BACKGROUND: The use of computed tomographic (CT) scans in the United States (US) has increased more than 3-fold since 1993 to approximately 70 million scans annually. Despite the great medical benefits, there is concern about the potential radiation-related cancer risk. We conducted detailed estimates of the future cancer risks from current CT scan use in the US according to age, sex, and scan type. METHODS: Risk models based on the National Research Council's "Biological Effects of Ionizing Radiation" report and organ-specific radiation doses derived from a national survey were used to estimate age-specific cancer risks for each scan type. These models were combined with age- and sex-specific scan frequencies for the US in 2007 obtained from survey and insurance claims data. We estimated the mean number of radiation-related incident cancers with 95% uncertainty limits (UL) using Monte Carlo simulations. RESULTS: Overall, we estimated that approximately 29 000 (95% UL, 15 000-45 000) future cancers could be related to CT scans performed in the US in 2007. The largest contributions were from scans of the abdomen and pelvis (n = 14 000) (95% UL, 6900-25 000), chest (n = 4100) (95% UL, 1900-8100), and head (n = 4000) (95% UL, 1100-8700), as well as from chest CT angiography (n = 2700) (95% UL, 1300-5000). One-third of the projected cancers were due to scans performed at the ages of 35 to 54 years compared with 15% due to scans performed at ages younger than 18 years, and 66% were in females. CONCLUSIONS: These detailed estimates highlight several areas of CT scan use that make large contributions to the total cancer risk, including several scan types and age groups with a high frequency of use or scans involving relatively high doses, in which risk-reduction efforts may be warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,154
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
The United Nations Scientific Committee on the Effects of Atomic Radiation
(1965) · Nature · doi:10.1038/206014c0 · Cited by 1,636
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 3×
“6 (1) 150 (70-300) 1 30 (10-60) 1 180 (80-400) 1 Otherd 3.”
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
NCRP report no. 93: Ionizing radiation exposure of the population of the United States
Eckelman, W. C. (1988) · International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology · doi:10.1016/0883-2897(88)90020-7 · Cited by 755
Estimated Radiation Risks Potentially Associated with Full-Body CT Screening
Brenner, D. J., & Elliston, C. D. (2004) · Radiology · doi:10.1148/radiol.2323031095 · Cited by 685
Radiation Effects on Breast Cancer Risk: A Pooled Analysis of Eight Cohorts
Preston, D. L., Mattsson, A., Holmberg, E., Shore, R., Hildreth, N. G., & Boice, J. D. (2002) · Radiation Research · doi:10.1667/0033-7587(2002)158[0220:reobcr]2.0.co;2 · Cited by 512
The Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental Data
Tubiana, M., Feinendegen, L. E., Yang, C., & Kaminski, J. M. (2009) · Radiology · doi:10.1148/radiol.2511080671 · Cited by 509
MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
Mettler, F. A., Thomadsen, B. R., Bhargavan, M., Gilley, D. B., Gray, J. E., Lipoti, J. A., McCrohan, J., Yoshizumi, T. T., & Mahesh, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326333.42287.a2 · Cited by 507
Maynard, C. D., Bryan, R. N., & Hattery, R. R. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja5510 · Cited by 476
Effective dose: how should it be applied to medical exposures?
Martin, C. J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/25922439 · Cited by 377
CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT
Stamm, G., & Nagel, H. D. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-35937 · Cited by 353
Little, M. P., Wakeford, R., Tawn, E. J., Bouffler, S. D., & Berrington de Gonzalez, A. (2009) · Radiology · doi:10.1148/radiol.2511081686 · Cited by 353
Contents, preface, executive summary, chapters 1 and 2
Valentin, J. (2005) · Annals of the ICRP · doi:10.1016/j.icrp.2005.11.002 · Cited by 269
Griffey, R. T., & Sodickson, A. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1351 · Cited by 258
Patient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
Estimating Cancer Risks from Low Doses of Ionizing Radiation
Land, C. E. (1980) · Science · doi:10.1126/science.7403879 · Cited by 249
Coronary Artery Calcification Screening: Estimated Radiation Dose and Cancer Risk
Kim, K. P., Einstein, A. J., & Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.162 · Cited by 236
Self-citationde González, A. B., Kim, K. P., & Berg, C. D. (2008) · Journal of Medical Screening · doi:10.1258/jms.2008.008052 · Cited by 130
Hunter, N., & Muirhead, C. R. (2009) · Journal of Radiological Protection · doi:10.1088/0952-4746/29/1/r01 · Cited by 100
Computing effective doses to pediatric patients undergoing body CT examinations
Huda, W., & Ogden, K. M. (2008) · Pediatric Radiology · doi:10.1007/s00247-007-0732-6 · Cited by 34
Cited by
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Self-citationFihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Metadata
- Authors
- Berrington de González, A.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2009-12-14
- Volume
- 169
- Issue
- 22
- Pages
- 2071
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2170260757
- Cited by
- 1,888
- References
- 32
- FWCI
- 104.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.