The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Discriminating Between Normal and Glaucomatous Eyes Using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph
Abstract
OBJECTIVE: To compare the ability of 3 instruments, the Heidelberg Retina Tomograph (HRT), the GDx Nerve Fiber Analyzer (GDx), and the Optical Coherence Tomograph (OCT), to discriminate between healthy eyes and eyes with early to moderate glaucomatous visual field loss. SUBJECTS AND METHODS: Forty-one patients with early to moderate glaucomatous visual field loss and 50 healthy subjects were included in the study. The HRT, GDx, and OCT imaging and visual field testing were completed on 1 eye from each subject within a 6-month interval. Statistical differences in sensitivity at fixed specificities of 85%, 90%, and 95% were evaluated. In addition, areas under the receiver operating characteristic (ROC) curve were compared. RESULTS: No significant differences were found between the area under the ROC curve and the best parameter from each instrument: OCT thickness at the 5-o'clock inferior temporal position (mean +/- SE, 0.87 +/- 0.04), HRT mean height contour in the nasal inferior region (mean +/- SE, 0.86 +/- 0.04), and GDx linear discriminant function (mean +/- SE, 0.84 +/- 0.04). Twelve HRT, 2 GDx, and 9 OCT parameters had an area under the ROC curve of at least 0.81. At a fixed specificity of 90%, significant differences were found between the sensitivity of OCT thickness at the 5-o'clock inferior temporal position (71%) and parameters with sensitivities less than 52%. Qualitative assessment of stereophotographs resulted in a sensitivity of 80%. CONCLUSION: Although the area under the ROC curves was similar among the best parameters from each instrument, qualitative assessment of stereophotographs and measurements from the OCT and HRT generally had higher sensitivities than measurements from the GDx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Optic Nerve Damage in Human Glaucoma: II. The Site of Injury and Susceptibility to Damage
Quigley, H. A. (1981) · Archives of Ophthalmology · doi:10.1001/archopht.1981.03930010635009 · Cited by 1,244
Quigley, H. A. (1982) · Archives of Ophthalmology · doi:10.1001/archopht.1982.01030030137016 · Cited by 1,177
Schuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Reproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
The Nerve Fiber Layer in the Diagnosis of Glaucoma
Sommer, A., Miller, N. R., Pollack, I., Maumenee, A. E., & George, T. (1977) · Archives of Ophthalmology · doi:10.1001/archopht.1977.04450120055003 · Cited by 435
Blumenthal, E. Z., Williams, J. M., Weinreb, R. N., Girkin, C. A., Berry, C. C., & Zangwill, L. M. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00341-9 · Cited by 316
Self-citationBowd, C. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.22 · Cited by 308
The Effect of Age on Normal Human Optic Nerve Fiver Number and Diameter
Repka, M. X., & Quigley, H. A. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32928-9 · Cited by 296
Histomorphometry of the human optic nerve.
Jonas, J. B., Müller-Bergh, J. A., Schlötzer-Schrehardt, U. M., & Naumann, G. O. H. (1990) · PubMed · Cited by 263
Mikelberg, F. S., Drance, S. M., Schulzer, M., Yidegiligne, H. M., & Weis, M. M. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32718-7 · Cited by 263
Detection of Glaucoma With Scanning Laser Polarimetry
Weinreb, R. N. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.12.1583 · Cited by 231
Detection of structural damage from glaucoma with confocal laser image analysis.
Uchida, H., Brigatti, L., & Caprioli, J. (1996) · PubMed · Cited by 190
The Effect of Optic Disc Size on Diagnostic Precision with the Heidelberg Retina Tomograph
Iester, M., Mikelberg, F. S., & Drance, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30277-2 · Cited by 167
Is Neuroprotection a Viable Therapy for Glaucoma?
Weinreb, R. N. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.11.1540 · Cited by 114
Neural Networks to Identify Glaucoma With Structural and Functional Measurements
Brigatti, L., Hoffman, D. C., & Caprioli, J. (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75425-x · Cited by 92
Estimating Diagnostic Test Accuracy Using a "Fuzzy Gold Standard"
Phelps, C. E., & Hutson, A. D. (1995) · Medical Decision Making · doi:10.1177/0272989x9501500108 · Cited by 73
Cited by
Weinreb, R. N., & Khaw, P. T. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16257-0 · Cited by 2,222
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Jonas, J. B., Aung, T., Bourne, R. R., Bron, A. M., Ritch, R., & Panda-Jonas, S. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31469-1 · Cited by 1,322
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Medeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.069 · Cited by 649
Self-citation
Metadata
- Authors
- Zangwill, L. M.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2001-07-01
- Volume
- 119
- Issue
- 7
- Pages
- 985
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2164974115
- Cited by
- 344
- References
- 17
- FWCI
- 24.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.