Spectral Domain Optical Coherence Tomography: Ultra-high Speed, Ultra-high Resolution Ophthalmic Imaging
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS: Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS: In vivo images of the retina, the optic nerve head, and retinal blood flow were obtained at an ultra-high speed of 34.1 microseconds (ms) per A-scan, which is 73 times faster than commercially available optical coherence tomography instruments. Single images (B-scans) consisting of 1000 A-scans were acquired in 34.1 ms, allowing video rate imaging at 29 frames per second with an axial resolution of 6 mum. Using a different source in a slightly slower configuration, single images consisting of 500 A-scans were acquired in 34 ms, allowing imaging at 29 frames per second at an axial resolution of 3.5 microm, which is 3 times better than commercially available optical coherence tomography instruments. The amount of energy directed into the eye in both cases, 600 microW, is less than that of the Stratus OCT3 and is safe for intrabeam viewing for up to 8 hours at the same retinal location. CONCLUSION: Spectral domain optical coherence tomography technology enables ophthalmic imaging with unprecedented simultaneous ultra-high speed and ultra-high resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Number of people with glaucoma worldwide.
Quigley, H. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.5.389 · Cited by 2,998
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
Important Causes of Visual Impairment in the World Today
Congdon, N. G. (2003) · JAMA · doi:10.1001/jama.290.15.2057 · Cited by 698
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
Nassif, N., Cense, B., Hyle Park, B., Yun, S. H., Chen, T. C., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.000480 · Cited by 498
Self-citationDrexler, W. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.5.695 · Cited by 467
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Self-citationIp, M. S. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.1.29 · Cited by 381
Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping
Zeimer, R. C., Asrani, S., Zou, S., Quigley, H. A., & JAMPEL, H. D. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)92743-9 · Cited by 268
Cense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1160 · Cited by 221
Self-citationKo, T. H., Fujimoto, J. G., Duker, J. S., Paunescu, L. A., Drexler, W., Baumal, C. R., Puliafito, C. A., Reichel, E., ROGERS, A., & Schuman, J. S. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.05.021 · Cited by 212
Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography.
Muscat, S., McKay, N., Parks, S., Kemp, E., & Keating, D. (2002) · PubMed · Cited by 191
Longitudinal Prevalence of Major Eye Diseases
Lee, P. P. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.9.1303 · Cited by 138
Optical coherence tomography of cystoid macular edema associated with retinitis pigmentosa
Hirakawa, H., Iijima, H., Gohdo, T., & Tsukahara, S. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00100-2 · Cited by 138
Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography.
Strøm, C., Sander, B., Larsen, N. B., Larsen, M., & Lund‐Andersen, H. (2002) · PubMed · Cited by 117
Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography
Wirbelauer, C., Scholz, C., Hoerauf, H., Pham, D. T., Laqua, H., & Birngruber, R. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01425-8 · Cited by 114
Fujimoto, J. G. (2001) · CRC Press eBooks · doi:10.1201/b14024-2 · Cited by 75
Optical coherence tomography imaging of severe commotio retinae and associated macular hole
Ismail, R. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.4.473-a · Cited by 30
IMAGING ANALYSIS WITH OPTICAL COHERENCE TOMOGRAPHY
Zolf, R., Glacet-Bernard, A., Benhamou, N., Mimoun, G., COSCAS, G. J., & Soubrane, G. (2002) · Retina · doi:10.1097/00006982-200204000-00010 · Cited by 14
APPLICATION OF THE RETINAL THICKNESS ANALYZER TO THE DIAGNOSIS AND MANAGEMENT OF OCULAR DISEASES
Zeimer, R. C. (1998) · Ophthalmology Clinics of North America · doi:10.1016/s0896-1549(05)70062-6 · Cited by 12
Cited by
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Makita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Spectral-Domain OCT Measurements in Alzheimer’s Disease
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.08.009 · Cited by 360
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Schuman, S. G., Koreishi, A. F., Farsiu, S., Jung, S.-H., Izatt, J. A., & Toth, C. A. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.10.006 · Cited by 280
Metadata
- Authors
- Chen, T. C.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2005-12-01
- Volume
- 123
- Issue
- 12
- Pages
- 1715
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2051779939
- Cited by
- 327
- References
- 23
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.