Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With Glaucoma
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether intraocular pressure (IOP) monitoring outside of normal office hours adds clinically useful information. METHODS: We reviewed the records of all patients with glaucoma who were admitted for 24-hour IOP monitoring during 3 years. Applanation IOP was recorded in the sitting position from 7 am until midnight and in the supine position at 6 am. RESULTS: Thirty-two patients (22 women and 10 men) were enrolled (mean +/- SD age, 67.3 +/- 12.1 years). Mean +/- SD 24-hour IOP was 13.0 +/- 2.2 mm Hg. Mean +/- SD peak 24-hour IOP (16.8 +/- 3.2 mm Hg) was significantly higher than peak office IOP (14.7 +/- 3.2 mm Hg) (P<.001). Peak IOP was recorded outside of office hours in at least 1 eye in 22 patients (69%). Mean IOP fluctuation during 24-hour monitoring (6.9 +/- 2.9 mm Hg) was significantly greater than that during office hours (3.8 +/- 2.3 mm Hg) (P<.001). Peak 24-hour IOP was higher than the peak IOP noted during previous office visits in 40 eyes (62%). Results of 24-hour IOP monitoring led to immediate treatment change in 23 eyes (36%). CONCLUSIONS: In glaucoma patients with advanced disease or progression that are disproportionate to known IOP measurements, 24-hour monitoring of IOP may reveal a greater role for pressure-related risk for glaucoma progression than previously suspected and may alter treatment strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Factors for Glaucoma Progression and the Effect of Treatment: The Early Manifest Glaucoma Trial
Leske, M. C. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.1.48 · Cited by 2,030
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 901
Nouri-Mahdavi, K., Hoffman, D., Coleman, A. L., Liu, G., Li, G., Gaasterland, D., & Caprioli, J. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.017 · Cited by 704
Twenty-four-Hour Intraocular Pressure Pattern Associated with Early Glaucomatous Changes
Liu, J. H. K., Zhang, X., Kripke, D. F., & Weinreb, R. N. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0666 · Cited by 444
Compliance with Topical Pilocarpine Treatment
Kass, M. A., Meltzer, D. W., Gordon, M., Cooper, D., & Goldberg, J. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90939-6 · Cited by 341
Twenty-four-hour pattern of intraocular pressure in the aging population.
Liu, J. H., Kripke, D. F., Twa, M. D., Hoffman, R. E., Mansberger, S. L., Rex, K. M., Girkin, C. A., & Weinreb, R. N. (1999) · PubMed · Cited by 293
Nocturnal elevation of intraocular pressure in young adults.
Liu, J. H., Kripke, D. F., Hoffman, R. E., Twa, M. D., Loving, R. T., Rex, K. M., Gupta, N., & Weinreb, R. N. (1998) · PubMed · Cited by 285
Cited by
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
“Numerous recent prospective and retrospective articles (Rota-Bartelink et al. 1996; Graham & Drance 1999; Pointer 1999; Asrani et al. 2000; Liu 2001; Wax et al. 2002; Hughes et al. 2003; Denis 2004; Wilensky 2004; Blaise & Guillaume 2005; Barkana et al. 2006) have pointed out that 24-hr IOP monitoring frequently leads…”
BackgroundNormal-tension glaucoma: is it different from primary open-angle glaucoma?
Shields, M. B. (2008) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e3282f3919b · Cited by 255
Mansouri, K., & Shaarawy, T. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 232
“Their findings were confirmed by numerous studies showing that IOP measurements during routine office hours fail to detect peak IOP in up to 62% of glaucoma patients.”
BackgroundWhy Do People (Still) Go Blind from Glaucoma?
Susanna, R., De Moraes, C. G., Cioffi, G. A., & Ritch, R. (2015) · Translational Vision Science & Technology · doi:10.1167/tvst.4.2.1 · Cited by 198
“Limitations to these approaches are that more than 50% of IOP peaks occur outside office hours.(52) In addition to this”
InfluentialMeta-analysis of 24-Hour Intraocular Pressure Studies Evaluating the Efficacy of Glaucoma Medicines
Stewart, W. C., Konstas, A. G. P., Nelson, L. A., & Kruft, B. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.10.004 · Cited by 190
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.2280 · Cited by 180
“Yet, IOP is a dynamic parameter with distinct circadian rhythms that vary among individuals, and single IOP measurements may fail to reflect the true range of an individual’s IOP.5,6 Currently, the most common methods for studying glaucoma patients’ 24- hour IOP rhythm are through a diurnal tension curve or while hosp…”
Fogagnolo, P., Orzalesi, N., Ferreras, A., & Rossetti, L. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2889 · Cited by 75
“The inadequacy of office-hour sitting readings in patients with severe or progressing glaucoma has been shown by Barkana et al.(10): nearly 70% of peak IOP were lost and fluctuations were underestimated by a mean of 3 mm Hg.”
BackgroundResultInfluentialCavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Noninvasive intraocular pressure monitoring: Current insights
De Smedt, S. (2015) · Clinical ophthalmology · doi:10.2147/opth.s53772 · Cited by 29
“Particularly in patients with progressive visual field loss that is disproportionate to measured IOP, monitoring of the IOP provides additional information.(7,33) It has been shown that analyzing IOP curves allows a more accurate detection of the IOP fluctuations and peak values, which occur outside office hours in 52…”
Metadata
- Authors
- Barkana, Y.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2006-06-01
- Volume
- 124
- Issue
- 6
- Pages
- 793
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2098477882
- Cited by
- 278
- References
- 27
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.