Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer Thickness
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We describe a new technique for the measurement of retinal nerve fiber layer thickness and compare its results with histopathologic measurements in the same eyes. For these studies, two fixed monkey eyes were incised and placed on a pedestal in a plastic viewing dish. The eyes were perfused to maintain a pressure between 10 and 20 mm Hg. An ellipsometer, an optical device used to measure the change in polarization of light (retardation), was implemented in a laser tomographic scanner to obtain polarization data from the two monkey retinas. For the 15 measured locations, retardation ranged between a mean (+/- SD) of 0.9 degrees +/- 1.8 degrees and 23.7 degrees +/- 0.3 degrees. Subsequently, retinal nerve fiber layer thickness was measured at the imaged points in epoxy resin-embedded sections by an observer masked to the ellipsometry data. These values ranged between 20.4 microns and 213.9 microns. There was an excellent correlation (R = .83) between retardation and the histopathologic measurement of retinal nerve fiber layer thickness. Quantitating retinal nerve fiber layer thickness may enhance discrimination between glaucomatous and normal eyes earlier than is currently available by anatomic and functional approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Introduction to Probability and Statistics
(2015) · Environmental Risk Analysis · doi:10.1201/b19097-5 · Cited by 1,153
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Photopolarimetric measurement of the Mueller matrix by Fourier analysis of a single detected signal
Azzam, R. M. A. (1978) · Optics Letters · doi:10.1364/ol.2.000148 · Cited by 500
Diffuse and Localized Nerve Fiber Loss in Glaucoma
Airaksinen, P. J., Drance, S. M., Douglas, G. R., Mawson, D. K., & Nieminen, H. (1984) · American Journal of Ophthalmology · doi:10.1016/0002-9394(84)90242-3 · Cited by 243
Evaluation of Nerve Fiber Layer Assessment
Sommer, A., Quigley, H. A., Robin, A. L., Miller, N. R., Katz, J., & Arkell, S. (1984) · Archives of Ophthalmology · doi:10.1001/archopht.1984.01040031430017 · Cited by 213
Mueller matrix ellipsometry with imperfect compensators
Hauge, P. S. (1978) · Journal of the Optical Society of America · doi:10.1364/josa.68.001519 · Cited by 171
Cited by
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Weinreb, R. N., & Khaw, P. T. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16257-0 · Cited by 2,222
Self-citationOptical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Schuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Ophthalmoscopic Evaluation of the Optic Nerve Head
Jonas, J. B., Budde, W. M., & Panda-Jonas, S. (1999) · Survey of Ophthalmology · doi:10.1016/s0039-6257(98)00049-6 · Cited by 607
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Medeiros, F. A. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.6.827 · Cited by 455
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Stokes-vector and Mueller-matrix polarimetry [Invited]
Azzam, R. M. A. (2016) · Journal of the Optical Society of America A · doi:10.1364/josaa.33.001396 · Cited by 259
Detection of Glaucoma With Scanning Laser Polarimetry
Weinreb, R. N. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.12.1583 · Cited by 231
Self-citationGreenfield, D. S., Knighton, R. W., & Huang, X.-R. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00353-6 · Cited by 231
Cense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1160 · Cited by 221
“The first in vitro RNFL birefringence measurements were reported by Weinreb et al. 5 With SLP they measured two fixed primate eyes with the anterior segments removed and correlated the measured phase retardation with RNFL thickness histology measurements.”
BackgroundMethodInfluentialDreher, A. W., Reiter, K., & Weinreb, R. N. (1992) · Applied Optics · doi:10.1364/ao.31.003730 · Cited by 217
Self-citationCense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2002) · Optics Letters · doi:10.1364/ol.27.001610 · Cited by 182
Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications
Baumann, B. (2017) · Applied Sciences · doi:10.3390/app7050474 · Cited by 171
“Since the RNFL is damaged in glaucoma—the second leading cause of blindness worldwide [132]—and since RNFL birefringence is connected to layer integrity [133,134], the polarization properties of the RNFL were investigated as potential diagnostic markers for glaucoma.”
BackgroundDiagnostic accuracy of the GDx VCC for glaucoma
Reus, N. J., & Lemij, H. G. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.04.024 · Cited by 170
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1133 · Cited by 162
Self-citationJansonius, N. M., Nevalainen, J., Selig, B., Zangwill, L. M., Sample, P. A., Budde, W. M., Jonas, J. B., Lagrèze, W. A., Airaksinen, P. J., Vonthein, R., et al. (2009) · Vision Research · doi:10.1016/j.visres.2009.04.029 · Cited by 155
Metadata
- Authors
- Weinreb, R. N.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1990-04-01
- Volume
- 108
- Issue
- 4
- Pages
- 557
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1990724394
- Cited by
- 449
- References
- 7
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.