Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor: Safety, Tolerability, and Reproducibility in Patients With Glaucoma

Open access
Mansouri, Kaweh, Medeiros, Felipe A., Tafreshi, Ali, Weinreb, Robert N. · 2012 · Archives of Ophthalmology

Abstract

OBJECTIVE To examine the safety, tolerability, and reproducibility of intraocular pressure (IOP) patterns during repeated continuous 24-hour IOP monitoring with a contact lens sensor. METHODS Forty patients suspected of having glaucoma (n = 21) or with established glaucoma (n = 19) were studied. Patients participated in two 24-hour IOP monitoring sessions (S1 and S2) at a 1-week interval (SENSIMED Triggerfish CLS; Sensimed AG). Patients pursued daily activities, and sleep behavior was not controlled. Incidence of adverse events and tolerability (visual analog scale score) were assessed. Reproducibility of signal patterns was assessed using Pearson correlations. RESULTS The mean (SD) age of the patients was 55.5 (15.7) years, and 60% were male. Main adverse events were blurred vision (82%), conjunctival hyperemia (80%), and superficial punctate keratitis (15%). The mean (SD) visual analog scale score was 27.2 (18.5) mm in S1 and 23.8 (18.7) mm in S2 (P = .22). Overall correlation between the 2 sessions was 0.59 (0.51 for no glaucoma medication and 0.63 for glaucoma medication) (P = .12). Mean (SD) positive linear slopes of the sensor signal from wake to 2 hours into sleep were detected in both sessions for the no glaucoma medication group (S1: 0.40 [0.34], P < .001; S2: 0.33 [0.30], P < .01) but not for the glaucoma medication group (S1: 0.24 [0.60], P = .06; S2: 0.40 [0.40], P < .001). CONCLUSIONS Repeated use of the contact lens sensor demonstrated good safety and tolerability. The recorded IOP patterns showed fair to good reproducibility, suggesting that data from continuous 24-hour IOP monitoring may be useful in the management of patients with glaucoma. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01319617.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archophthalmol.2012.2280

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 180

Metadata

Authors
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N.
Venue
Archives of Ophthalmology
Published
2012-12-01
Volume
130
Issue
12
Pages
1534
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2136722967
Cited by
180
References
4
FWCI
13.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.