Wireless smart contact lens for diabetic diagnosis and therapy
Open accessAbstract
A smart contact lens can be used as an excellent interface between the human body and an electronic device for wearable healthcare applications. Despite wide investigations of smart contact lenses for diagnostic applications, there has been no report on electrically controlled drug delivery in combination with real-time biometric analysis. Here, we developed smart contact lenses for both continuous glucose monitoring and treatment of diabetic retinopathy. The smart contact lens device, built on a biocompatible polymer, contains ultrathin, flexible electrical circuits and a microcontroller chip for real-time electrochemical biosensing, on-demand controlled drug delivery, wireless power management, and data communication. In diabetic rabbit models, we could measure tear glucose levels to be validated by the conventional invasive blood glucose tests and trigger drugs to be released from reservoirs for treating diabetic retinopathy. Together, we successfully demonstrated the feasibility of smart contact lenses for noninvasive and continuous diabetic diagnosis and diabetic retinopathy therapy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Keum et al. used a smart contact lens with an electrochemical biosensor to continuously monitor glucose levels in tears and perform diabetic diagnosis and diabetic retinopathy therapy.
“In this regard, Keum et al. [219] used a smart contact lens with an electrochemical biosensor to continuously monitor glucose levels in tears and, thus, perform diabetic diagnosis and diabetic retinopathy therapy.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [219]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1× · see citing works
“In addition, there have been many reports on the electrical and optical glucose sensing with improved sensitivity using various nanomaterials ( 24 – 26 ).”
BackgroundWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884 · see citing works
Self-citationLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462 · see citing works
Self-citationLee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118 · see citing works
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951 · see citing works
Kim, D., Lu, N., Ghaffari, R., Kim, Y., Lee, S. P., Xu, L., Wu, J. C., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 766 · see citing works
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671 · see citing works
Self-citationRemotely Triggerable Drug Delivery Systems
Timko, B. P., Dvir, T., & Kohane, D. S. (2010) · Advanced Materials · doi:10.1002/adma.201002072 · Cited by 613 · see citing works
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · see citing works
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466 · see citing works
Self-citationFirst-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip
Farra, R., Sheppard, N. F., McCabe, L., Neer, R. M., Anderson, J., Santini, J. T., Cima, M. J., & Langer, R. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003276 · Cited by 442 · see citing works
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372 · see citing works
Lee, H., Kim, E., Lee, Y., Kim, H., Lee, J., Kim, M., Yoo, H., & Yoo, S. (2018) · Science Advances · doi:10.1126/sciadv.aas9530 · Cited by 277 · see citing works
Koo, J. H., Jeong, S., Shim, H. J., Son, D., Kim, J., Kim, D. C., Choi, S., Hong, J., & Kim, D. (2017) · ACS Nano · doi:10.1021/acsnano.7b04292 · Cited by 261 · see citing works
Self-citationTissue-adhesive wirelessly powered optoelectronic device for metronomic photodynamic cancer therapy
Yamagishi, K., Kirino, I., Takahashi, I., Amano, H., Takeoka, S., Morimoto, Y., & Fujie, T. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0261-7 · Cited by 241 · see citing works
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229 · see citing works
Extended delivery of ophthalmic drugs by silicone hydrogel contact lenses
Kim, J., Conway, A., & Chauhan, A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.030 · Cited by 223 · see citing works
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device
Prescott, J. H., Lipka, S., Baldwin, S. P., Sheppard, N. F., Maloney, J. M., Coppeta, J. R., Yomtov, B., Staples, M. A., & Santini, J. T. (2006) · Nature Biotechnology · doi:10.1038/nbt1199 · Cited by 220 · see citing works
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187 · see citing works
Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.2280 · Cited by 180 · see citing works
Chu, B., Burnett, W., Chung, J. W., & Bao, Z. (2017) · Nature · doi:10.1038/549328a · Cited by 161 · see citing works
Self-citationPseudoexfoliation syndrome, a systemic disorder with ocular manifestations
Elhawy, E., Kamthan, G., Dong, C. Q., et al. (2012) · Human Genomics · doi:10.1186/1479-7364-6-22 · Cited by 132 · see citing works
Nanoporous Gold-Based Biofuel Cells on Contact Lenses
Xiao, X., Siepenkoetter, T., Conghaile, P. Ó., Leech, D., & Magner, E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18708 · Cited by 130 · see citing works
Oh, E. J., Choi, J.-S., Kim, H., Joo, C.-K., & Hahn, S. K. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.003 · Cited by 77 · see citing works
Self-citationFormation and prevention of fractures in sol–gel-derived thin films
Kappert, E. J., Pavlenko, D., Malzbender, J., et al. (2014) · Soft Matter · doi:10.1039/c4sm02085e · Cited by 68 · see citing works
Liu, D., Wu, Q., Zhu, Y., Liu, Y., Xie, X., Li, S., Lin, H., Chen, W., & Zhu, F. (2019) · Drug Delivery · doi:10.1080/10717544.2019.1609623 · Cited by 57 · see citing works
Enhanced Glucose Sensor Linearity Using Poly(Vinyl Alcohol) Hydrogels
Vaddiraju, S., Singh, H., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300434 · Cited by 49 · see citing works
A Low-Power Wide Dynamic-Range Current Readout Circuit for Ion-Sensitive FET Sensors
Son, H., Cho, H., Koo, J., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2643784 · Cited by 37 · see citing works
Self-citationWong, F. L., & Aziz, A. A. (2007) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1774 · Cited by 31 · see citing works
Monitoring gastric myoelectric activity after pancreaticoduodenectomy for diet “readiness”
Dua, M. M., Navalgund, A. R., Axelrod, S., et al. (2018) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00074.2018 · Cited by 14 · see citing works
Berstein, L. M. (2018) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2018.1431123 · Cited by 11 · see citing works
Monitoring of Gastric Myoelectric Activity after Pancreaticoduodenectomy
Dua, M. M., Malhotra, L., Navalgund, A. R., Axelrod, S., Triadafilopoulos, G., & Visser, B. (2017) · Gastroenterology · doi:10.1016/s0016-5085(17)34317-2 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714 · see citing works
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535 · see citing works
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453 · see citing works
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Li, X., Huang, X., Mo, J., Wang, H., Huang, Q., Yang, C., Zhang, T., Chen, H., Hang, T., Liu, F., et al. (2021) · Advanced Science · doi:10.1002/advs.202100827 · Cited by 250 · see citing works
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237 · see citing works
Wearable and implantable devices for drug delivery: Applications and challenges
Kar, A., Ahamad, N., Dewani, M., Awasthi, L., Patil, R., & Banerjee, R. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121435 · Cited by 179 · see citing works
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187 · see citing works
- Authors
- Keum, D. H., Kim, S.-K., Koo, J., Lee, G.-H., Jeon, C., Mok, J. W., Mun, B. H., Lee, K. J., Kamrani, E., Joo, C.-K., Shin, S., Sim, J.-Y., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K.
- Affiliations
- Pohang University of Science and Technology (KR)
- The Catholic University of Korea Seoul St. Mary's Hospital (KR)
- Korea Advanced Institute of Science and Technology (KR)
- Harvard University (US)
- PHI BIOMED Co., #613, 12 Gangnam-daero 65-gil, Seocho-gu, Seoul 06612, Korea.
- Stanford Medicine (US)
- Stanford University (US)
- Corresponding author
- Hahn, Sei Kwang
- ORCID
- Venue
- Science Advances
- Published
- 2020-04-24
- Volume
- 6
- Issue
- 17
- Pages
- eaba3252-eaba3252
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC7182412
- OpenAlex
- W3006183395
- Cited by
- 483
- References
- 34
- Citations by year
- 2026: 51 · 2025: 94 · 2024: 81 · 2023: 89 · 2022: 73 · 2021: 78 · 2020: 17
- FWCI
- 20.19
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Open Access System for Information Sharing (Pohang University of Science and Technology) (submittedVersion)
- Funders
- the National Research Foundation (2017R1E1A1A03070458, CASE-2015M3A6A5072945)
- Samsung Science & Technology Foundation (SRFC-IT1401-03)
- the Small and Medium Business Administration (S2482887)
- the National Eye Institute (K08EY028176, P30-EY026877)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- smart contact lens, continuous glucose monitoring, diabetic retinopathy, on-demand drug delivery, electrochemical biosensing, tear glucose, wearable healthcare, flexible electronics, biocompatible polymers, microcontroller
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review