Catheter-Induced Ablation of the Atrioventricular Junction to Control Refractory Supraventricular Arrhythmias
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Five patients with recurrent bouts of supraventricular tachycardia proved resistant or became intolerant of both conventional and experimental drugs. These patients were subjected to a new procedure involving delivery of DC shocks to an electrode catheter positioned adjacent to the His bundle. Complete atrioventricular (AV) block was produced in all, one patient died suddenly six weeks after shock therapy, and the remainder had complete AV block with follow-up intervals ranging from four to 12 months. Shock therapy was associated with mild elevations of creatine phosphokinase MB (31 +/- 18 units), but there was no hemodynamic evidence of tricuspid insufficiency. If this new technique proves safe and effective, it should supplant the need for open heart surgical procedures for His-bundle ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gallagher, J. J., Svenson, R. H., Kasell, J. H., German, L. D., Bardy, G. H., Broughton, A., & Critelli, G. (1982) · New England Journal of Medicine · doi:10.1056/nejm198201283060402 · Cited by 771
Cited by
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
The surgical treatment of atrial fibrillation
Cox, J. L., Schuessler, R. B., D’Agostino, H. J., Stone, C. M., Chang, B.-C., Cain, M. E., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36684-x · Cited by 1,464
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.95.6.1611 · Cited by 759
Prystowsky, E. N., Benson, D. W., Fuster, V., Hart, R. G., Kay, G. N., Myerburg, R. J., Naccarelli, G. V., & Wyse, D. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1262 · Cited by 635
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Calkins, H., Yong, P., Miller, J. M., Olshansky, B., Carlson, M., Saul, J. P., Huang, S. K. S., Liem, L. B., Klein, L. S., Moser, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.2.262 · Cited by 611
Hemodynamic Effects of an Irregular Sequence of Ventricular Cycle Lengths During Atrial Fibrillation
Clark, D. M., Plumb, V. J., Epstein, A. E., & Kay, G. N. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00254-4 · Cited by 609
Right and Left Atrial Radiofrequency Catheter Therapy of Paroxysmal Atrial Fibrillation
HAÍSSAGUERRE, M., JAÍS, P., SHAH, D. C., GENCEL, L., PRADEAU, V., GARRIGUES, S., CHOUAIRI, S., HOCINI, M., LE MÉTAYER, P., ROUDAUT, R., et al. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00492.x · Cited by 577
Five-year experience with the maze procedure for atrial fibrillation
Cox, J. L., Boineau, J. P., Schuessler, R. B., Kater, K. M., & Lappas, D. G. (1993) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(93)90338-i · Cited by 491
Jazayeri, M. R., Hempe, S. L., Sra, J. S., Dhala, A. A., Blanck, Z., Deshpande, S. S., Avitall, B., Krum, D. P., Gilbert, C. J., & Akhtar, M. (1992) · Circulation · doi:10.1161/01.cir.85.4.1318 · Cited by 489
An 8½-Year Clinical Experience with Surgery for Atrial Fibrillation
Cox, J. L., Schuessler, R. B., Lappas, D. G., & Boineau, J. P. (1996) · Annals of Surgery · doi:10.1097/00000658-199609000-00003 · Cited by 428
Huang, S. K., Bharati, S., Graham, A. R., Lev, M., Marcus, F. I., & Odell, R. C. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80388-1 · Cited by 374
Radiofrequency current catheter ablation of accessory atrioventricular pathways
Kuck, K.-H., Schluter, M., Geiger, M., Siebels, J., & Duckeck, W. (1991) · The Lancet · doi:10.1016/0140-6736(91)93258-b · Cited by 363
Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping System
Pappone, C., Oreto, G., Lamberti, F., Vicedomini, G., Loricchio, M. L., Shpun, S., Rillo, M., Calabrò, M. P., Conversano, A., Ben-Haim, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.100.11.1203 · Cited by 354
Successful Catheter Ablation of Atrial Fibrillation
HAÏSSAGUERRE, M., GENCEL, L., FISCHER, B., LE MÉTAYER, P., POQUET, F., MARCUS, F. I., & CLEMÉNTY, J. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01146.x · Cited by 334
Ozcan, C., Jahangir, A., Friedman, P. A., Patel, P. J., Munger, T. M., Rea, R. F., Lloyd, M. A., Packer, D. L., Hodge, D. O., Hayes, D. L., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104053441403 · Cited by 329
Prevention of recurrent atrial fibrillation with chronic dual-site right atrial pacing
Saksena, S., Prakash, A., Hill, M., Krol, R. B., Munsif, A. N., Mathew, P. P., & Mehra, R. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00232-x · Cited by 325
Atrial fibrillation: current knowledge and recommendations for management*1
LEVY, S. (1998) · European Heart Journal · doi:10.1053/euhj.1998.1050 · Cited by 323
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
High frequency alternating current ablation of an accessory pathway in humans
Borggrefe, M., Budde, T., Podczeck, A., & Breithardt, G. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80200-0 · Cited by 285
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Catheter ablation of the atrioventricular junction with radiofrequency energy.
Langberg, J. J., Chin, M. C., Rosenqvist, M., Cockrell, J., Dullet, N., Van Hare, G., Griffin, J. C., & Scheinman, M. M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1527 · Cited by 245
Self-citationScheinman, M. M., & Evans-Bell, T. (1984) · Circulation · doi:10.1161/01.cir.70.6.1024 · Cited by 202
Self-citationElvan, A., Pride, H. P., Eble, J. N., & Zipes, D. P. (1995) · Circulation · doi:10.1161/01.cir.91.8.2235 · Cited by 184
Fisher, J. D., Brodman, R., Kim, S. G., Matos, J. A., Elizabeth Brodman, L., Wallerson, D., & Waspe, L. E. (1984) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(84)80394-0 · Cited by 183
Jackman, W. M., Wang, X. Z., Friday, K. J., Fitzgerald, D. M., Roman, C., Moulton, K., Margolis, P. D., Bowman, A. J., Kuck, K. H., & Naccarelli, G. V. (1991) · Circulation · doi:10.1161/01.cir.83.5.1562 · Cited by 178
JCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12491 · Cited by 164
Morady, F., & Scheinman, M. M. (1984) · New England Journal of Medicine · doi:10.1056/nejm198403153101108 · Cited by 163
Self-citationEdner, M., Caidahl, K., Bergfeldt, L., Darpo, B., Edvardsson, N., & Rosenqvist, M. (1995) · Heart · doi:10.1136/hrt.74.3.261 · Cited by 127
The first Latin American Catheter Ablation Registry
Keegan, R., Aguinaga, L., Fenelon, G., Uribe, W., Rodriguez Diez, G., Scanavacca, M., Patete, M., Carhuaz, R. Z., Labadet, C., De Zuloaga, C., et al. (2015) · EP Europace · doi:10.1093/europace/euu322 · Cited by 52
“Transcatheter ablation of cardiac arrhythmias was successfully introduced into daily clinical practice over 30 years ago.(1,2) Since then, surveys and multicentre registries have mainly been reported from centres across the Europe and the USA,(3) –5 whereas in Latin America registries are limited to a few countries.”
BackgroundPatel, N. J., Deshmukh, A., Pau, D., Goyal, V., Patel, S. V., Patel, N., Agnihotri, K., Asirvatham, S., Noseworthy, P., Di Biase, L., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.02.005 · Cited by 46
Ablate and pace revisited: long term survival and predictors of permanent atrial fibrillation
Queiroga, A., Marshall, H. J., Clune, M., & Gammage, M. D. (2003) · Heart · doi:10.1136/heart.89.9.1035 · Cited by 36
Metadata
- Authors
- Scheinman, M. M.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1982-08-20
- Volume
- 248
- Issue
- 7
- Pages
- 851
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1994407295
- Cited by
- 836
- References
- 1
- FWCI
- 22.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.