The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Association Between Transcatheter Aortic Valve Replacement for Bicuspid vs Tricuspid Aortic Stenosis and Mortality or Stroke
Open accessAbstract
Importance: Transcatheter aortic valve replacement (TAVR) indications are expanding, leading to an increasing number of patients with bicuspid aortic stenosis undergoing TAVR. Pivotal randomized trials conducted to obtain US Food and Drug Administration approval excluded bicuspid anatomy. Objective: To compare the outcomes of TAVR with a balloon-expandable valve for bicuspid vs tricuspid aortic stenosis. Design, Setting, and Participants: Registry-based prospective cohort study of patients undergoing TAVR at 552 US centers. Participants were enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapies Registry from June 2015 to November 2018. Exposures: TAVR for bicuspid vs tricuspid aortic stenosis. Main Outcomes and Measures: Primary outcomes were 30-day and 1-year mortality and stroke. Secondary outcomes included procedural complications, valve hemodynamics, and quality of life assessment. Results: Of 81 822 consecutive patients with aortic stenosis (2726 bicuspid; 79 096 tricuspid), 2691 propensity-score matched pairs of bicuspid and tricuspid aortic stenosis were analyzed (median age, 74 years [interquartile range {IQR}, 66-81 years]; 39.1%, women; mean [SD] STS-predicted risk of mortality, 4.9% [4.0%] and 5.1% [4.2%], respectively). All-cause mortality was not significantly different between patients with bicuspid and tricuspid aortic stenosis at 30 days (2.6% vs 2.5%; hazard ratio [HR], 1.04, [95% CI, 0.74-1.47]) and 1 year (10.5% vs 12.0%; HR, 0.90 [95% CI, 0.73-1.10]). The 30-day stroke rate was significantly higher for bicuspid vs tricuspid aortic stenosis (2.5% vs 1.6%; HR, 1.57 [95% CI, 1.06-2.33]). The risk of procedural complications requiring open heart surgery was significantly higher in the bicuspid vs tricuspid cohort (0.9% vs 0.4%, respectively; absolute risk difference [RD], 0.5% [95% CI, 0%-0.9%]). There were no significant differences in valve hemodynamics. There were no significant differences in moderate or severe paravalvular leak at 30 days (2.0% vs 2.4%; absolute RD, 0.3% [95% CI, -1.3% to 0.7%]) and 1 year (3.2% vs 2.5%; absolute RD, 0.7% [95% CI, -1.3% to 2.7%]). At 1 year there was no significant difference in improvement in quality of life between the groups (difference in improvement in the Kansas City Cardiomyopathy Questionnaire overall summary score, -2.4 [95% CI, -5.1 to 0.3]; P = .08). Conclusions and Relevance: In this preliminary, registry-based study of propensity-matched patients who had undergone transcatheter aortic valve replacement for aortic stenosis, patients with bicuspid vs tricuspid aortic stenosis had no significant difference in 30-day or 1-year mortality but had increased 30-day risk for stroke. Because of the potential for selection bias and the absence of a control group treated surgically for bicuspid stenosis, randomized trials are needed to adequately assess the efficacy and safety of transcatheter aortic valve replacement for bicuspid aortic stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationSurgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients
Reardon, M. J., Van Mieghem, N. M., Popma, J. J., Kleiman, N. S., Søndergaard, L., Mumtaz, M., Adams, D. H., Deeb, G. M., Maini, B., Gada, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700456 · Cited by 3,009
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal
Gentry III, J. L., Phelan, D., Desai, M. Y., & Griffin, B. P. (2017) · Cardiology · doi:10.1159/000460274 · Cited by 2,725
Green, C. P., Porter, C. B., Bresnahan, D. R., & Spertus, J. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00531-3 · Cited by 1,827
Kappetein, A. P., Head, S. J., Genereux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs533 · Cited by 1,601
Self-citationHiggins (2002) · doi:10.1002/(issn)1097-0258 · Cited by 1,248
A classification system for the bicuspid aortic valve from 304 surgical specimens
Sievers, H.-H., & Schmidtke, C. (2007) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.039 · Cited by 1,222
Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves
Makkar, R. R., Fontana, G., Jilaihawi, H., Chakravarty, T., Kofoed, K. F., De Backer, O., Asch, F. M., Ruiz, C. E., Olsen, N. T., Trento, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509233 · Cited by 1,051
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs255 · Cited by 1,043
Self-citationRoberts, W. C., & Ko, J. M. (2005) · Circulation · doi:10.1161/01.cir.0000155623.48408.c5 · Cited by 1,000
Chakravarty, T., Søndergaard, L., Friedman, J., De Backer, O., Berman, D., Kofoed, K. F., Jilaihawi, H., Shiota, T., Abramowitz, Y., Jørgensen, T. H., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30757-2 · Cited by 909
Self-citationMonitoring clinical changes in patients with heart failure: A comparison of methods
Spertus, J., Peterson, E., Conard, M. W., Heidenreich, P. A., Krumholz, H. M., Jones, P., McCullough, P. A., Pina, I., Tooley, J., Weintraub, W. S., et al. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.12.010 · Cited by 562
Yoon, S.-H., Bleiziffer, S., De Backer, O., Delgado, V., Arai, T., Ziegelmueller, J., Barbanti, M., Sharma, R., Perlman, G. Y., Khalique, O. K., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.017 · Cited by 489
Self-citationClinical Outcomes at 1 Year Following Transcatheter Aortic Valve Replacement
Holmes, D. R., Brennan, J. M., Rumsfeld, J. S., Dai, D., O’Brien, S. M., Vemulapalli, S., Edwards, F. H., Carroll, J., Shahian, D., Grover, F., et al. (2015) · JAMA · doi:10.1001/jama.2015.1474 · Cited by 477
Self-citationOutcomes Following Transcatheter Aortic Valve Replacement in the United States
Mack, M. J., Brennan, J. M., Brindis, R., Carroll, J., Edwards, F., Grover, F., Shahian, D., Tuzcu, E. M., Peterson, E. D., Rumsfeld, J. S., et al. (2013) · JAMA · doi:10.1001/jama.2013.282043 · Cited by 474
Self-citationMichelena, H. I., Prakash, S. K., Della Corte, A., Bissell, M. M., Anavekar, N., Mathieu, P., Bossé, Y., Limongelli, G., Bossone, E., Benson, D. W., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007851 · Cited by 442 · cited 1×
“In accordance with prior studies, the KCCQ-OS scores were categorized as very poor (<25), poor (25-49), fair (50-74), and good (≥75) quality of life.”
MethodTranscatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease
Mylotte, D., Lefevre, T., Søndergaard, L., Watanabe, Y., Modine, T., Dvir, D., Bosmans, J., Tchetche, D., Kornowski, R., Sinning, J.-M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.039 · Cited by 344
An echocardiographic survey of primary school children for bicuspid aortic valve
Basso, C., Boschello, M., Perrone, C., Mecenero, A., Cera, A., Bicego, D., Thiene, G., & De Dominicis, E. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.11.031 · Cited by 324
Durko, A. P., Osnabrugge, R. L., Van Mieghem, N. M., Milojevic, M., Mylotte, D., Nkomo, V. T., & Pieter Kappetein, A. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy107 · Cited by 304
Prognostic Value of Health Status in Patients With Heart Failure After Acute Myocardial Infarction
Soto, G. E., Jones, P., Weintraub, W. S., Krumholz, H. M., & Spertus, J. A. (2004) · Circulation · doi:10.1161/01.cir.0000136991.85540.a9 · Cited by 230
Yoon, S.-H., Lefèvre, T., Ahn, J.-M., Perlman, G. Y., Dvir, D., Latib, A., Barbanti, M., Deuschl, F., De Backer, O., Blanke, P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.06.041 · Cited by 227
Self-citationYoon, S.-H., Whisenant, B. K., Bleiziffer, S., Delgado, V., Schofer, N., Eschenbach, L., Fujita, B., Sharma, R., Ancona, M., Yzeiraj, E., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.714 · Cited by 219
Self-citationFrequency of Bicuspid Aortic Valve in Young Male Conscripts by Echocardiogram
Nistri, S., Basso, C., Marzari, C., Mormino, P., & Thiene, G. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.04.051 · Cited by 193
Bicuspid Aortic Valve Stenosis
Perlman, G. Y., Blanke, P., Dvir, D., Pache, G., Modine, T., Barbanti, M., Holy, E. W., Treede, H., Ruile, P., Neumann, F.-J., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.01.002 · Cited by 187
Arnold, S. V., Spertus, J. A., Lei, Y., Allen, K. B., Chhatriwalla, A. K., Leon, M. B., Smith, C. R., Reynolds, M. R., Webb, J. G., Svensson, L. G., et al. (2013) · Circulation: Heart Failure · doi:10.1161/circheartfailure.112.970053 · Cited by 181
Self-citationSeeger, J., Kapadia, S. R., Kodali, S., Linke, A. H.-P., Wöhrle, J., Haußig, S., Makkar, R., Mehran, R., Rottbauer, W., & Leon, M. B. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy847 · Cited by 94
Self-citationHira, R. S., Vemulapalli, S., Li, Z., McCabe, J. M., Rumsfeld, J. S., Kapadia, S. R., Alam, M., Jneid, H. M., Don, C. W., Reisman, M., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.1685 · Cited by 86
Self-citationGoland, S., Czer, L. S. C., Robertis, M. A. D., Mirocha, J., Kass, R. M., Fontana, G. P., Chang, W., & Trento, A. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.10.047 · Cited by 66
Self-citationPettersen, K. I., Reikvam, A., Rollag, A., & Stavem, K. (2004) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2004.05.012 · Cited by 57
D’Agostino (1998) · doi:10.1002/(sici)1097-0258(19981015)17:19<2265::aid-sim918>3.0.co;2-b
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Self-citationOtto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
Self-citation2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
Self-citation2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.035 · Cited by 1,075
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Metadata
- Authors
- Makkar, R. R., Yoon, S.-H., Leon, M. B., Chakravarty, T., Rinaldi, M., Shah, P. B., Skipper, E. R., Thourani, V. H., Babaliaros, V., Cheng, W., Trento, A., Vemulapalli, S., Kapadia, S. R., Kodali, S., Mack, M. J., Tang, G. H. L., & Kaneko, T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2019-06-11
- Volume
- 321
- Issue
- 22
- Pages
- 2193
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2950068502
- Cited by
- 316
- References
- 36
- FWCI
- 28.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.