The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Antihypertensive Treatment Based on Blood Pressure Measurement at Home or in the Physician's Office<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>
Abstract
CONTEXT: Self-measurement of blood pressure is increasingly used in clinical practice, but how it affects the treatment of hypertension requires further study. OBJECTIVE: To compare use of blood pressure (BP) measurements taken in physicians' offices and at home in the treatment of patients with hypertension. DESIGN, SETTING, AND PARTICIPANTS: Blinded randomized controlled trial conducted from March 1997 to April 2002 at 56 primary care practices and 3 hospital-based outpatient clinics in Belgium and 1 specialized hypertension clinic in Dublin, Ireland. Four hundred participants with a diastolic BP (DBP) of 95 mm Hg or more as measured at physicians' offices were enrolled and followed up for 1 year. INTERVENTIONS: Antihypertensive drug treatment was adjusted in a stepwise fashion based on either the self-measured DBP at home (average of 6 measurements per day during 1 week; n = 203) or the average of 3 sitting DBP readings at the physician's office (n = 197). If the DBP guiding treatment was above (>89 mm Hg), at (80-89 mm Hg), or below (<80 mm Hg) target, a physician blinded to randomization intensified antihypertensive treatment, left it unchanged, or reduced it, respectively. MEAN OUTCOME MEASURES: Office and home BP levels, 24-hour ambulatory BP, intensity of drug treatment, electrocardiographic and echocardiographic left ventricular mass, symptoms reported by questionnaire, and costs of treatment. RESULTS: At the end of the study (median follow-up, 350 days; interquartile range, 326-409 days), more home BP than office BP patients had stopped antihypertensive drug treatment (25.6% vs 11.3%; P<.001) with no significant difference in the proportions of patients progressing to multiple-drug treatment (38.7% vs 45.1%; P =.14). The final office, home, and 24-hour ambulatory BP measurements were higher (P<.001) in the home BP group than in the office BP group. The mean baseline-adjusted systolic/diastolic differences between the home and office BP groups averaged 6.8/3.5 mm Hg, 4.9/2.9 mm Hg, and 4.9/2.9 mm Hg, respectively. Left ventricular mass and reported symptoms were similar in the 2 groups. Costs per 100 patients followed up for 1 month were only slightly lower in the home BP group (3875 vs 3522 [4921 dollars vs 4473 dollars]; P =.04). CONCLUSIONS: Adjustment of antihypertensive treatment based on home BP instead of office BP led to less intensive drug treatment and marginally lower costs but also to less BP control, with no differences in general well-being or left ventricular mass. Self-measurement allowed identification of patients with white-coat hypertension. Our findings support a stepwise strategy for the evaluation of BP in which self-measurement and ambulatory monitoring are complementary to conventional office measurement and highlight the need for prospective outcome studies to establish the normal range of home-measured BP.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent United States and European guidelines, new and lower OBP targets were proposed based on the evidence from observational studies, from few specifically designed interventional trials, in particular SPRINT [152], and from recent meta-analyses [153,154]”
In the citing paper
“The THOP and the HOMERUS trials were the first to examine the efficacy of antihypertensive titration using HBPM [158,159], but their results are undermined by major limitations as the same BP target for both randomization arms was considered, and differences in BP titration and blinding were maintained with the prescribing physician unaware of randomization group”
Citations
Cites
Sahn, D. J., DeMaria, A. N., KISSLO, J. A., & Weyman, A. E. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Analysis of serial measurements in medical research.
Matthews, J. N. S., Altman, D. G., Campbell, M. J., & Royston, P. J. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,137
Mancia, G., Rosei, E. A., Cífková, R., DeBacker, G., Erdine, S. E., Fagard, R., Farsang, C., Heagerty, A. M., Kawecka-Jaszcs, K., Kiowski, W., et al. (2003) · Lirias (KU Leuven) · doi:10.1097/01.hjh.0000059051.65882.32 · Cited by 2,601
Self-citationSokolow, M., & Lyon, T. P. (1949) · American Heart Journal · doi:10.1016/0002-8703(49)90562-1 · Cited by 1,990
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationBlood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E. T., Waeber, B., Parati, G., Staessen, J. A., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 906
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 746
Ambulatory blood pressure normality: results from the PAMELA study
Mancia, G., Sega, R., Bravi, C., Vito, G. D., Valagussa, F., Cesana, G., & Zanchetti, A. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512000-00003 · Cited by 619
Casale, P. N., Devereux, R. B., Alonso, D. R., Campo, E., & Kligfield, P. (1987) · Circulation · doi:10.1161/01.cir.75.3.565 · Cited by 561
Alterations of Cardiac Structure in Patients With Isolated Office, Ambulatory, or Home Hypertension
Sega, R., Trocino, G., Lanzarotti, A., Carugo, S., Cesana, G., Schiavina, R., Valagussa, F., Bombelli, M., Giannattasio, C., Zanchetti, A., et al. (2001) · Circulation · doi:10.1161/hc3701.096100 · Cited by 512
Cardiovascular prevention and blood pressure reduction
Staessen, J. A., Wang, J., & Thijs, L. (2003) · Journal of Hypertension · doi:10.1097/00004872-200306000-00002 · Cited by 483
Self-citationMolloy, T. J., Okin, P. M., Devereux, R. B., & Kligfield, P. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90376-x · Cited by 406
Antihypertensive Treatment Based on Conventional or Ambulatory Blood Pressure Measurement
Staessen, J. A. (1997) · JAMA · doi:10.1001/jama.278.13.1065 · Cited by 274
Self-citationEchocardiographic assessment of left ventricular hypertrophy
Reichek, N. (1982) · European Heart Journal · doi:10.1093/eurheartj/3.suppl_a.49 · Cited by 233
Guidelines for the use of self-blood pressure monitoring
Asmar, R. G., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 214
Age-specific relevance of usual blood pressure to vascular mortality
Lewington, S., Clarke, R., Qizilbash, N., Peto, R., & Collins, R. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13064-4 · Cited by 197
Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143
Self-citationSelf-measured versus ambulatory blood pressure in the diagnosis of hypertension
den Hond, E., Celis, H., Fagard, R., Keary, L., Leeman, M., O'Brien, E., Vandenhoven, G., & Staessen, J. (2003) · Journal of Hypertension · doi:10.1097/00004872-200304000-00014 · Cited by 129
Self-citationBobrie, G., Genès, N., Vaur, L., Clerson, P., Vaisse, B., Mallion, J.-M., & Chatellier, G. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.18.2205 · Cited by 117
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
An epidemiological approach to ambulatory blood pressure monitoring:the Belgian Population Study.
Staessen, J. A., Bieniaszewski, L., O'Brien, E. T., Imai, Y., & Fagard, R. (1996) · PubMed · Cited by 113
Self-citationVerdecchia, P., Schillaci, G., Borgioni, C., Ciucci, A., & Porcellati, C. (1996) · The Lancet · doi:10.1016/s0140-6736(04)70084-7 · Cited by 98
Home blood pressure: variability, comparison with office readings and proposal for reference values
de Gaudemaris, R., Nguyen, C. P., & Mallion, J. (1994) · Journal of Hypertension · doi:10.1097/00004872-199407000-00016 · Cited by 98
Thijs, L., Staessen, J. A., Celis, H., Fagard, R., Cort, P. D., de Gaudemaris, R., Enström, I., lmai, Y., Julius, S., Ménard, J., et al. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199902000-00004 · Cited by 67
Self-citationThe Tecumseh Blood Pressure Study
Mejia, A. D. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00390180049008 · Cited by 59
Júnior, H. D. C. C. (1996) · American Journal of Hypertension · doi:10.1093/ajh/9.4.28a · Cited by 56
Home blood pressure normalcy: The Didima study
Stergiou, G. S., Thomopoulou, G., Skeva, I. I., & Mountokalakis, T. D. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00266-6 · Cited by 55
Celis, H., Cort, P. D., Fagard, R., Thijs, L., & Staessen, J. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000517 · Cited by 47
Self-citationWeisser, B., Mengden, T., Düsing, R., Vetter, H., & Vetter, W. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)00259-4 · Cited by 38
Left ventricular mass regression in the LIFE study: effect of previous antihypertensive treatment
Aurigemma, G. P. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)03258-2 · Cited by 13
Flagged first, then by citations
Cited by
Sorted by citations
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citation
Metadata
- Authors
- Staessen, J. A.
- Affiliations
- KU Leuven (BE)
- Corresponding author
- Staessen, Jan A.
- ORCID
- Staessen, Jan A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2004-02-25
- Volume
- 291
- Issue
- 8
- Pages
- 955
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2096784990
- Cited by
- 288
- References
- 34
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 5 · 2021: 2 · 2020: 8 · 2019: 14 · 2018: 12 · 2017: 11 · 2016: 13 · 2015: 18 · 2014: 13 · 2013: 21 · 2012: 23
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- JAMA (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- hypertension, antihypertensive therapy, home blood pressure monitoring, self-measured blood pressure, office blood pressure measurement, treatment intensification, ambulatory blood pressure, left ventricular mass, antihypertensive drug costs, treatment discontinuation, primary care, hypertension clinic, ambulatory blood pressure monitoring
- MeSH terms
- Antihypertensive Agents, Echocardiography, Electrocardiography, Fees, Medical, Female, Humans, Hypertension, Male, Middle Aged, Office Visits, Self Care, Single-Blind Method, Cost Savings, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review