The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Noninvasive Coronary Angiography With Multislice Computed Tomography
Abstract
CONTEXT: Multislice computed tomography (MSCT) has recently evolved as a modality for noninvasive coronary imaging. OBJECTIVE: To assess the accuracy and robustness of MSCT vs the criterion standard of invasive coronary angiography for detection of obstructive coronary artery disease. DESIGN, SETTING, AND PATIENTS: Prospective, single-center study conducted in a referral center setting in Germany and enrolling 103 consecutive patients (mean age, 61.5 [SD, 9.7] years) from November 2003-August 2004 who were undergoing both invasive coronary angiography and MSCT using a scanner with 16 detector rows. MAIN OUTCOME MEASURES: Blinded results for both modalities compared using the patient as the primary unit of analysis, with supplementary segment- and vessel-based analyses. RESULTS: One thousand three hundred eighty-four segments (> or =1.5 mm diameter) were identified by invasive coronary angiography; nondiagnostic image quality of MSCT was identified for only 88 (6.4%) of these segments, mainly due to faster heart rates. Compared with invasive coronary angiography for detection of significant lesions (>50% stenosis), segment-based sensitivity, specificity, and positive and negative predictive values of MSCT were 95%, 98%, 87%, and 99%, respectively. Quantitative comparison of MSCT and invasive coronary angiography showed good correlation (r = 0.87, P<.001), with MSCT systematically measuring greater-percentage stenoses (bias, +12%). In the patient-based analysis, the area under the receiver operating characteristic curve was 0.97 (95% confidence interval, 0.90-1.00), indicating high discriminative power to identify patients who might be candidates for revascularization (>50% left main artery stenosis and/or >70% stenosis in any other epicardial vessel). Threshold optimization allowed either detection of these patients with 100% sensitivity at a reasonable false-positive rate (specificity, 76.5%; MSCT stenosis, >66%) or optimization of both the sensitivity and specificity (>90%; MSCT stenosis, >76%). CONCLUSIONS: Multislice computed tomography provides high accuracy for noninvasive detection of suspected obstructive coronary artery disease. This promising technology has potential to complement diagnostic invasive coronary angiography in routine clinical care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Committee Members, Gibbons, R. J., Balady, G. J., Timothy Bricker, J., Chaitman, B. R., Fletcher, G. F., Froelicher, V. F., Mark, D. B., McCallister, B. D., Mooss, A. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000034670.06526.15 · Cited by 2,607
Thompson, I. M., Pauler, D. K., Goodman, P. J., Tangen, C. M., Lucia, M. S., Parnes, H. L., Minasian, L. M., Ford, L. G., Lippman, S. M., Crawford, E. D., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031918 · Cited by 2,446
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Some Practical Guidelines for Effective Sample Size Determination
Lenth, R. V. (2001) · The American Statistician · doi:10.1198/000313001317098149 · Cited by 1,139
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
A critical review of the systolic time intervals.
Lewis, R. P., Rittogers, S. E., Froester, W. F., & Boudoulas, H. (1977) · Circulation · doi:10.1161/01.cir.56.2.146 · Cited by 624
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Prostate Cancer and the Will Rogers Phenomenon
Albertsen, P. C., Hanley, J. A., Barrows, G. H., Penson, D. F., Kowalczyk, P. D. H., Sanders, M. M., & Fine, J. (2005) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/dji248 · Cited by 382
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Bashore, T. M., Bates, E. R., Berger, P. B., Clark, D. A., Cusma, J. T., Dehmer, G. J., Kern, M. J., Laskey, W. K., O’Laughlin, M. P., Oesterle, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01346-8 · Cited by 320
Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart Rate
Hoffmann, M. H. K., Shi, H., Manzke, R., Schmid, F. T., De Vries, L., Grass, M., Brambs, H.-J., & Aschoff, A. J. (2005) · Radiology · doi:10.1148/radiol.2341031408 · Cited by 264
Self-citationFundamentals of clinical research for radiologists
Joseph, L., & Reinhold, C. (2005) · American Journal of Roentgenology · Cited by 193
Noninvasive Imaging of Coronary Arteries: Current and Future Role of Multi–Detector Row CT
Schoenhagen, P., Halliburton, S. S., Stillman, A. E., Kuzmiak, S. A., Nissen, S. E., Tuzcu, E. M., & White, R. D. (2004) · Radiology · doi:10.1148/radiol.2321021803 · Cited by 190
Gönen, M., Panageas, K. S., & Larson, S. M. (2001) · Radiology · doi:10.1148/radiol.2212010280 · Cited by 111
Uehata, A., Matsuguchi, T., Bittl, J. A., Orav, E. J., Meredith, I. T., Anderson, T. J., Selwyn, A. P., Ganz, P., & Yeung, A. C. (1993) · Circulation · doi:10.1161/01.cir.88.4.1724 · Cited by 104
Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
Manzke, R., Graß, M., Nielsen, T., Shechter, G., & Hawkes, D. J. (2003) · Medical Physics · doi:10.1118/1.1624756 · Cited by 97
Automatic phase determination for retrospectively gated cardiac CT
Manzke, R., Köhler, T., Nielsen, T., Hawkes, D. J., & Graß, M. (2004) · Medical Physics · doi:10.1118/1.1791351 · Cited by 63
Artifact Analysis and Reconstruction Improvement in Helical Cardiac Cone Beam CT
Manzke, R., Graß, M., & Hawkes, D. J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.830804 · Cited by 32
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., & Nieman, K. (2004) · ACC Current Journal Review · doi:10.1016/j.accreview.2004.08.063 · Cited by 31
Cited by
Motoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
Multislice Computed Tomographic Characteristics of Coronary Lesions in Acute Coronary Syndromes
Motoyama, S., Kondo, T., Sarai, M., Sugiura, A., Harigaya, H., Sato, T., Inoue, K., Okumura, M., Ishii, J., Anno, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.044 · Cited by 1,026
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Metadata
- Authors
- Hoffmann, M. H. K.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2005-05-25
- Volume
- 293
- Issue
- 20
- Pages
- 2471
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2105371863
- Cited by
- 507
- References
- 22
- FWCI
- 59.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.