Comparison of a Polymer-Based Paclitaxel-Eluting Stent With a Bare Metal Stent in Patients With Complex Coronary Artery Disease: A Randomized Controlled Trial
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
CONTEXT: Compared with bare metal stents, drug-eluting stents reduce restenosis in noncomplex lesions. The utility of drug-eluting stents has not been evaluated in more difficult stenoses. OBJECTIVE: To investigate the safety and efficacy of the polymer-based, slow-release paclitaxel-eluting stent in a patient population with more complex lesions than previously studied. DESIGN, SETTING, AND PATIENTS: Prospective, placebo-controlled, double-blind, multicenter randomized trial conducted from February 2003 to March 2004 at 66 academic and community-based institutions with 1156 patients who underwent stent implantation in a single coronary artery stenosis (vessel diameter, 2.25-4.0 mm; lesion length, 10-46 mm), including 664 patients (57.4%) with complex or previously unstudied lesions (requiring 2.25-mm, 4.0-mm, and/or multiple stents) and 9-month clinical and angiographic follow-up. INTERVENTIONS: Patients were randomly assigned to receive 1 or more bare metal stents (n = 579) or identical-appearing paclitaxel-eluting stents (n = 577). MAIN OUTCOME MEASURE: Ischemia-driven target vessel revascularization at 9 months. RESULTS: Baseline characteristics were well matched. Diabetes was present in 31% of patients. The mean (SD) reference vessel diameter was 2.69 (0.57) mm, the reference lesion length was 17.2 (9.2) mm, and 78% of lesions were type B2/C. A mean (SD) of 1.38 (0.58) stents (total mean [SD] length, 28.4 [13.1] mm) were implanted per lesion; 33% of lesions required multiple stents. Stents that were 2.25 mm and 4.0 mm in diameter were used in 18% and 17% of lesions, respectively. Compared with bare metal stents, paclitaxel-eluting stents reduced the 9-month rate of target lesion revascularization from 15.7% to 8.6% (P<.001) and target vessel revascularization from 17.3% to 12.1% (P = .02). Similar rates were observed for cardiac death or myocardial infarction (5.5% for bare metal stent group vs 5.7% for paclitaxel-eluting stent group) and stent thrombosis (0.7% in both groups). Angiographic restenosis was reduced from 33.9% to 18.9% in the entire study cohort (P<.001), including among patients receiving 2.25-mm stents (49.4% vs 31.2%; P = .01), 4.0-mm stents (14.4% vs 3.5%; P = .02), and multiple stents (57.8% vs 27.2%; P<.001). CONCLUSION: Compared with a bare metal stent, implantation of the paclitaxel-eluting stent in a patient population with complex lesions effectively reduces clinical and angiographic restenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citationAngiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Self-citationColombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Self-citationPredictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Serruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Clinical restenosis after coronary stenting: perspectives from multicenter clinical trials
Cutlip, D. E., Chauhan, M. S., Baim, D. S., Ho, K. K. L., Popma, J. J., Carrozza, J. P., Cohen, D. J., & Kuntz, R. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02597-4 · Cited by 423
Self-citationArdissino, D., Cavallini, C., Bramucci, E., Indolfi, C., Marzocchi, A., Manari, A., Angeloni, G., Carosio, G., Bonizzoni, E., Colusso, S., et al. (2004) · JAMA · doi:10.1001/jama.292.22.2727 · Cited by 314
van der Zwet, P. M. J., & Reiber, J. H. C. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90566-5 · Cited by 205
Cited by
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Self-citationStent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationKing, S. B., Smith, S. C., Hirshfeld, J. W., Jacobs, A. K., Morrison, D. A., Williams, D. O., 2005 WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.188208 · Cited by 1,014
Guidelines on myocardial revascularization
The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2010.08.019 · Cited by 1,004
Camenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Hong, S.-J., Kim, B.-K., Shin, D.-H., Nam, C.-M., Kim, J.-S., Ko, Y.-G., Choi, D., Kang, T.-S., Kang, W.-C., Her, A.-Y., et al. (2015) · JAMA · doi:10.1001/jama.2015.15454 · Cited by 621
2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Stone, G. W. (2008) · JAMA · doi:10.1001/jama.299.16.1903 · Cited by 582
Self-citationKirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.826479 · Cited by 577
Self-citationBangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Attubato, M. J., Feit, F., Bhatt, D. L., & Slater, J. (2012) · Circulation · doi:10.1161/circulationaha.112.097014 · Cited by 574
Drug-Eluting Stents vs. Coronary-Artery Bypass Grafting in Multivessel Coronary Disease
Hannan, E. L., Wu, C., Walford, G., Culliford, A. T., Gold, J. P., Smith, C. R., Higgins, R. S. D., Carlson, R. E., & Jones, R. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071804 · Cited by 541
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Late Thrombosis of Drug-Eluting Stents: A Meta-Analysis of Randomized Clinical Trials
Bavry, A. A., Kumbhani, D. J., Helton, T. J., Borek, P. P., Mood, G. R., & Bhatt, D. L. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2006.01.023 · Cited by 490
Nordmann, A. J., Briel, M., & Bucher, H. C. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl282 · Cited by 480
Long-Term Safety of Drug-Eluting and Bare-Metal Stents
Palmerini, T., Benedetto, U., Biondi-Zoccai, G., Della Riva, D., Bacchi-Reggiani, L., Smits, P. C., Vlachojannis, G. J., Jensen, L. O., Christiansen, E. H., Berencsi, K., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.017 · Cited by 470
Self-citationKastrati, A., Dibra, A., Spaulding, C., Laarman, G. J., Menichelli, M., Valgimigli, M., Di Lorenzo, E., Kaiser, C., Tierala, I., Mehilli, J., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm402 · Cited by 373
Biofunctionalization of Biomaterials for Accelerated in Situ Endothelialization: A Review
de Mel, A., Jell, G., Stevens, M. M., & Seifalian, A. M. (2008) · Biomacromolecules · doi:10.1021/bm800681k · Cited by 351
The Problem With Composite End Points in Cardiovascular Studies
Kip, K. E., Hollabaugh, K., Marroquin, O. C., & Williams, D. O. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.034 · Cited by 348
Kandzari, D. E., Leon, M. B., Popma, J. J., Fitzgerald, P. J., O’Shaughnessy, C., Ball, M. W., Turco, M., Applegate, R. J., Gurbel, P. A., Midei, M. G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.035 · Cited by 347
Self-citationThe power prior: theory and applications
Ibrahim, J. G., Chen, M., Gwon, Y., & Chen, F. (2015) · Statistics in Medicine · doi:10.1002/sim.6728 · Cited by 341
Kastrati, A., Dibra, A., Mehilli, J., Mayer, S., Pinieck, S., Pache, J., Dirschinger, J., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.601823 · Cited by 312
A Comparison of Bare-Metal and Drug-Eluting Stents for Off-Label Indications
Marroquin, O. C., Selzer, F., Mulukutla, S. R., Williams, D. O., Vlachos, H. A., Wilensky, R. L., Tanguay, J.-F., Holper, E. M., Abbott, J. D., Lee, J. S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706258 · Cited by 270
Jensen, L. O., Maeng, M., Kaltoft, A., Thayssen, P., Hansen, H. H. T., Bottcher, M., Lassen, J. F., Krussel, L. R., Rasmussen, K., Hansen, K. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.002 · Cited by 263
Bangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Kirtane, A. J., Byrne, R. A., Williams, D. O., Slater, J., Cutlip, D. E., & Feit, F. (2012) · BMJ · doi:10.1136/bmj.e5170 · Cited by 231
Drug eluting stents: an updated meta-analysis of randomised controlled trials
Roiron, C., Sanchez, P., Bouzamondo, A., Lechat, P., & Montalescot, G. (2006) · Heart · doi:10.1136/hrt.2005.061622 · Cited by 210
Nitric Oxide: A Guardian for Vascular Grafts?
de Mel, A., Murad, F., & Seifalian, A. M. (2011) · Chemical Reviews · doi:10.1021/cr200008n · Cited by 188
The Taxus™ drug-eluting stent: A new paradigm in controlled drug delivery
Kamath, K. R., Barry, J. J., & Miller, K. M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.023 · Cited by 174
The Evolution of Coronary Stents: A Brief Review
Simard, T., Hibbert, B., Ramirez, F. D., Froeschl, M., Chen, Y.-X., & O'Brien, E. R. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.09.012 · Cited by 160
Allocco, D. J., Cannon, L. A., Britt, A., Heil, J. E., Nersesov, A., Wehrenberg, S., Dawkins, K. D., & Kereiakes, D. J. (2010) · Trials · doi:10.1186/1745-6215-11-1 · Cited by 159
Self-citationNitric oxide and nitrite-based therapeutic opportunities in intimal hyperplasia
Alef, M. J., Tzeng, E., & Zuckerbraun, B. S. (2012) · Nitric Oxide · doi:10.1016/j.niox.2012.03.014 · Cited by 20
Metadata
- Authors
- Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., Koglin, J., Russell, M. E., & TAXUS V Investigators, F. T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2005-09-14
- Volume
- 294
- Issue
- 10
- Pages
- 1215
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2141469367
- Cited by
- 765
- References
- 13
- FWCI
- 71.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.