Variability in Ejection Fraction Measured By Echocardiography, Gated Single-Photon Emission Computed Tomography, and Cardiac Magnetic Resonance in Patients With Coronary Artery Disease and Left Ventricular Dysfunction
Open accessAbstract
Importance: Clinical decisions are frequently based on measurement of left ventricular ejection fraction (LVEF). Limited information exists regarding inconsistencies in LVEF measurements when determined by various imaging modalities and the potential impact of such variability. Objective: To determine the intermodality variability of LVEF measured by echocardiography, gated single-photon emission computed tomography (SPECT), and cardiovascular magnetic resonance (CMR) in patients with left ventricular dysfunction. Design, Setting, and Participants: International multicenter diagnostic study with LVEF imaging performed at 127 clinical sites in 26 countries from July 24, 2002, to May 5, 2007, and measured by core laboratories. Secondary study of clinical diagnostic measurements of LVEF in the Surgical Treatment for Ischemic Heart Failure (STICH), a randomized trial to identify the optimal treatment strategy for patients with LVEF of 35% or less and coronary artery disease. Data analysis was conducted from March 19, 2016, to May 29, 2018. Main Outcomes and Measures: At baseline, most patients had an echocardiogram and subsets of patients underwent SPECT and/or CMR. Left ventricular ejection fraction was measured by a core laboratory for each modality independent of the results of other modalities, and measurements were compared among imaging methods using correlation, Bland-Altman plots, and coverage probability methods. Association of LVEF by each method and death was assessed. Results: A total of 2032 patients (mean [SD] age, 60.9 [9.6] years; 1759 [86.6%] male) with baseline LVEF data were included. Correlation of LVEF between modalities was r = 0.601 (for biplane echocardiography and SPECT [n = 385]), r = 0.493 (for biplane echocardiography and CMR [n = 204]), and r = 0.660 (for CMR and SPECT [n = 134]). Bland-Altman plots showed only moderate agreement in LVEF measurements from all 3 core laboratories with no substantial overestimation or underestimation of LVEF by any modality. The percentage of observations that fell within a range of 5% ranged from 43% to 54% between different imaging modalities. Conclusions and Relevance: In this international multicenter study of patients with coronary artery disease and reduced LVEF, there was substantial variation between modalities in LVEF determination by core laboratories. This variability should be considered in clinical management and trial design. Trial Registration: Clinicaltrials.gov Identifier: NCT00023595.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Echocardiography LVEF measurement is less precise relative to other approaches such as magnetic resonance imaging.
“This might also be attributable to a lack of precision in LVEF measurement by echocardiography, which has shown to be less precise relative to other approaches, such as magnetic resonance imaging27,28.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [27]
The Results (Comparison of Imaging Modalities; page unavailable) show greater disagreement between echocardiography and CMR than between CMR and SPECT, supporting a concern about variability in echocardiographic LVEF measurements. But the Discussion and Limitations say there is no gold standard and do not establish that echocardiography itself is less precise than CMR; the study primarily compares agreement between modalities. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,022 · see citing works
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 32
- [1]Zaret BL, Wackers FJ, Terrin ML,; TIMI Study Group Value of radionuclide rest and exercise left ventricular ejection fraction in assessing survival of patients after thrombolytic therapy for acute myocardial infarction: results of Thrombolysis in Myocardial Infarction (TIMI) phase II study. J Am Coll Cardiol. 1995; 26(1):-. doi: 10.1016/0735-1097(95)00146-Q 7797778 · DOI
- [2]Volpi A, De Vita C, Franzosi MG,; Ad Hoc Working Group of the Gruppo Italiano per lo Studio della Sopravvivenza nell’Infarto Miocardico (GISSI)-2 Data Base Determinants of 6-month mortality in survivors of myocardial infarction after thrombolysis: results of the GISSI-2 data base. Circulation. 1993; 88(2): 416- 429. doi: 10.1161/01.CIR.88.2.416 8339405 · DOI
- [3]Burns RJ, Gibbons RJ, Yi Q,; CORE Study Investigators The relationships of left ventricular ejection fraction, end-systolic volume index and infarct size to six-month mortality after hospital discharge following myocardial infarction treated by thrombolysis. J Am Coll Cardiol. 2002; 39(1): 30- 36. doi: 10.1016/S0735-1097(01)01711-9 11755283 · DOI
- [4]Cohn J, Johnson G, Shabetai R Ejection fraction, peak exercise oxygen consumption, cardiothoracic ratio, ventricular arrhythmias, and plasma norepinephrine as determinants of prognosis in heart failure. Circulation. 1993; 87(suppl 6): V15- V16. 8500240
- [5]Gradman A, Deedwania P, Cody R,; Captopril-Digoxin Study Group Predictors of total mortality and sudden death in mild to moderate heart failure. J Am Coll Cardiol. 1989; 14(3): 564- 570. doi: 10.1016/0735-1097(89)90093-4 2768707 · DOI
- [6]Glover DR, Littler WA Factors influencing survival and mode of death in severe chronic ischaemic cardiac failure. Br Heart J. 1987; 57(2): 125- 132. doi: 10.1136/hrt.57.2.125 3814447 PMC1277092 · DOI
- [7]Dahl JS, Eleid MF, Michelena HI, Effect of left ventricular ejection fraction on postoperative outcome in patients with severe aortic stenosis undergoing aortic valve replacement. Circ Cardiovasc Imaging. 2015; 8(4): 8. doi: 10.1161/CIRCIMAGING.114.002917 25852129 · DOI · Paper page
- [8]Tracy CM, Epstein AE, Darbar D, 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2012; 60(14): 1297- 1313. doi: 10.1016/j.jacc.2012.07.009 22975230 · DOI
- [9]Yancy CW, Jessup M, Bozkurt B,; Writing Committee Members 2016 ACC/AHA/HFSA focused update on new pharmacological therapy for heart failure: an update of the 2013 ACCF/AHA guideline for the management of heart failure: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure Society of America. Circulation. 2016; 134(13): e282- e293. doi: 10.1161/CIR.0000000000000435 27208050 · DOI
- [11]Yusuf S, Pitt B, Davis CE, Hood WB Jr, Cohn JN; SOLVD Investigators Effect of enalapril on mortality and the development of heart failure in asymptomatic patients with reduced left ventricular ejection fractions. N Engl J Med. 1992; 327(10): 685- 691. doi: 10.1056/NEJM199209033271003 1463530 · DOI · Paper page
- [12]Xie BQ, Tian YQ, Zhang J, Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy: comparison with cardiac MRI. J Nucl Med. 2012; 53(4): 584- 591. doi: 10.2967/jnumed.111.096057 22393224 · DOI
- [13]Herregods MC, De Paep G, Bijnens B, Determination of left ventricular volume by two-dimensional echocardiography: comparison with magnetic resonance imaging. Eur Heart J. 1994; 15(8): 1070- 1073. doi: 10.1093/oxfordjournals.eurheartj.a060630 7988598 · DOI
- [14]Hoffmann R, von Bardeleben S, ten Cate F, Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography. Eur Heart J. 2005; 26(6): 607- 616. doi: 10.1093/eurheartj/ehi083 15618026 · DOI
- [15]Jones RH, Velazquez EJ, Michler RE,; STICH Hypothesis 2 Investigators Coronary bypass surgery with or without surgical ventricular reconstruction. N Engl J Med. 2009; 360(17): 1705- 1717. doi: 10.1056/NEJMoa0900559 19329820 PMC3265934 · DOI
- [16]Velazquez EJ, Lee KL, O’Connor CM,; STICH Investigators The rationale and design of the Surgical Treatment for Ischemic Heart Failure (STICH) trial. J Thorac Cardiovasc Surg. 2007; 134(6): 1540- 1547. doi: 10.1016/j.jtcvs.2007.05.069 18023680 PMC3638867 · DOI
- [17]Oh JK, Velazquez EJ, Menicanti L,; STICH Investigators Influence of baseline left ventricular function on the clinical outcome of surgical ventricular reconstruction in patients with ischaemic cardiomyopathy. Eur Heart J. 2013; 34(1): 39- 47. doi: 10.1093/eurheartj/ehs021 22584648 PMC3533917 · DOI
- [18]Lang RM, Badano LP, Mor-Avi V, Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015; 28(1): 1- 39 e14. doi: 10.1016/j.echo.2014.10.003 25559473 · DOI
- [19]Oh JK, Pellikka PA, Panza JA,; STICH Trial Investigators Core lab analysis of baseline echocardiographic studies in the STICH trial and recommendation for use of echocardiography in future clinical trials. J Am Soc Echocardiogr. 2012; 25(3): 327- 336. doi: 10.1016/j.echo.2011.12.002 22227341 PMC3310914 · DOI
- [20]Germano G, Kiat H, Kavanagh PB, Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995; 36(11): 2138- 2147. 7472611
- [21]Pohost GM, Hung L, Doyle M Clinical use of cardiovascular magnetic resonance. Circulation. 2003; 108(6): 647- 653. doi: 10.1161/01.CIR.0000083233.86078.3E 12912794 · DOI
- [23]Barnhart HX, Yow E, Crowley AL, Choice of agreement indices for assessing and improving measurement reproducibility in a core laboratory setting. Stat Methods Med Res. 2016; 25(6): 2939- 2958. doi: 10.1177/0962280214534651 24831133 · DOI
- [24]Herndon JE II, Harrell FE Jr The restricted cubic spline as baseline hazard in the proportional hazards model with step function time-dependent covariables. Stat Med. 1995; 14(19): 2119- 2129. doi: 10.1002/sim.4780141906 8552891 · DOI
- [25]Velazquez EJ, Lee KL, Jones RH,; STICHES Investigators Coronary-artery bypass surgery in patients with ischemic cardiomyopathy. N Engl J Med. 2016; 374(16): 1511- 1520. doi: 10.1056/NEJMoa1602001 27040723 PMC4938005 · DOI
- [26]Douglas PS, DeCara JM, Devereux RB,; American Society of Echocardiography Standards; American College of Cardiology Foundation Echocardiographic imaging in clinical trials: American Society of Echocardiography Standards for echocardiography core laboratories: endorsed by the American College of Cardiology Foundation. J Am Soc Echocardiogr. 2009; 22(7): 755- 765. doi: 10.1016/j.echo.2009.05.020 19560654 · DOI
- [27]Gaudio C, Tanzilli G, Mazzarotto P, Comparison of left ventricular ejection fraction by magnetic resonance imaging and radionuclide ventriculography in idiopathic dilated cardiomyopathy. Am J Cardiol. 1991; 67(5): 411- 415. doi: 10.1016/0002-9149(91)90051-L 1994666 · DOI
- [28]Dorosz JL, Lezotte DC, Weitzenkamp DA, Allen LA, Salcedo EE Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. J Am Coll Cardiol. 2012; 59(20): 1799- 1808. doi: 10.1016/j.jacc.2012.01.037 22575319 PMC3773600 · DOI
- [29]Wood PW, Choy JB, Nanda NC, Becher H Left ventricular ejection fraction and volumes: it depends on the imaging method. Echocardiography. 2014; 31(1): 87- 100. doi: 10.1111/echo.12331 24786629 PMC4231568 · DOI
- [30]Hundley WG, Kizilbash AM, Afridi I, Franco F, Peshock RM, Grayburn PA Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging. J Am Coll Cardiol. 1998; 32(5): 1426- 1432. doi: 10.1016/S0735-1097(98)00409-4 9809958 · DOI
- [31]Thomson HL, Basmadjian AJ, Rainbird AJ, Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: a prospective, randomly assigned, blinded study. J Am Coll Cardiol. 2001; 38(3): 867- 875. doi: 10.1016/S0735-1097(01)01416-4 11527647 · DOI
- [32]Tsang W, Salgo IS, Medvedofsky D, Transthoracic 3D echocardiographic left heart chamber quantification using an automated adaptive analytics algorithm. JACC Cardiovasc Imaging. 2016; 9(7): 769- 782. doi: 10.1016/j.jcmg.2015.12.020 27318718 · DOI
- [33]Konstam MA, Abboud FM Ejection fraction: misunderstood and overrated (changing the paradigm in categorizing heart failure). Circulation. 2017; 135(8): 717- 719. doi: 10.1161/CIRCULATIONAHA.116.025795 28223323 PMC5325053 · DOI
- [34]Cole GD, Dhutia NM, Shun-Shin MJ, Defining the real-world reproducibility of visual grading of left ventricular function and visual estimation of left ventricular ejection fraction: impact of image quality, experience and accreditation. Int J Cardiovasc Imaging. 2015; 31(7): 1303- 1314. doi: 10.1007/s10554-015-0659-1 26141526 PMC4572050 · DOI
Cited by
Sorted by citations
Bozkurt, B., Coats, A. J. S., Tsutsui, H., Abdelhamid, C. M., Adamopoulos, S., Albert, N., Anker, S. D., Atherton, J., Böhm, M., Butler, J., et al. (2021) · European Journal of Heart Failure · doi:10.1002/ejhf.2115 · Cited by 1,665 · see citing works
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153 · see citing works
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644 · see citing works
Detection of Left Ventricular Systolic Dysfunction From Electrocardiographic Images
Sangha, V., Nargesi, A. A., Dhingra, L. S., Khunte, A., Mortazavi, B. J., Ribeiro, A. H., Banina, E., Adeola, O., Garg, N., Brandt, C. A., et al. (2023) · Circulation · doi:10.1161/circulationaha.122.062646 · Cited by 150 · see citing works
Self-citationApplication of mobile health, telemedicine and artificial intelligence to echocardiography
Seetharam, K., Kagiyama, N., & Sengupta, P. P. (2019) · Echo Research & Practice · doi:10.1530/erp-18-0081 · Cited by 111 · see citing works
Khunte, A., Sangha, V., Oikonomou, E. K., Dhingra, L. S., Aminorroaya, A., Mortazavi, B. J., Coppi, A., Brandt, C. A., Krumholz, H. M., & Khera, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00869-w · Cited by 95 · see citing works
AI-Defined Cardiac Anatomy Improves Risk Stratification of Hybrid Perfusion Imaging
Miller, R. J. H., Shanbhag, A., Killekar, A., Lemley, M., Bednarski, B., Kavanagh, P. B., Feher, A., Miller, E. J., Bateman, T., Builoff, V., et al. (2024) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2024.01.006 · Cited by 33 · see citing works
Self-citationAssessing heart disease using a novel magnetocardiography device
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H. (2021) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abe5c5 · Cited by 18 · see citing works
- Authors
- Pellikka, P. A., She, L., Holly, T. A., Lin, G., Varadarajan, P., Pai, R. G., Bonow, R. O., Pohost, G. M., Panza, J. A., Berman, D. S., Prior, D. L., Asch, F. M., Borges-Neto, S., Grayburn, P., Al-Khalidi, H. R., Miszalski-Jamka, K., Desvigne-Nickens, P., Lee, K. L., Velazquez, E. J., & Oh, J. K.
- Affiliations
- Mayo Clinic (US)
- Duke University (US)
- Northwestern University (US)
- Loma Linda University (US)
- University of California, Riverside (US)
- Westchester Medical Center (US)
- Cedars-Sinai Medical Center (US)
- The University of Melbourne (AU)
- MedStar Washington Hospital Center (US)
- Division of Nuclear Medicine, Department of Radiology, Duke University School of Medicine, Durham, North Carolina
- Baylor University Medical Center (US)
- Duke Clinical Research Institute, Durham, North Carolina
- Division of Magnetic Resonance Imaging, Silesian Center for Heart Diseases, Zabrze, Poland
- National Institutes of Health (US)
- Corresponding author
- Pellikka, Patricia A.
- ORCID
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2018-08-31
- Volume
- 1
- Issue
- 4
- Pages
- e181456
- ISSN
- 2574-3805 (ISSN-L)
- PMC
- PMC6324278
- OpenAlex
- W2891975710
- Cited by
- 238
- References
- 2
- Citations by year
- 2026: 34 · 2025: 31 · 2024: 22 · 2023: 34 · 2022: 33 · 2021: 37 · 2020: 24 · 2019: 19 · 2018: 4
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JAMA Network Open (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Touro Scholar (Touro College) (submittedVersion, cc-by)
- Funders
- Amgen
- Pfizer
- Alnylam Pharmaceuticals
- Edwards Lifesciences
- Boston Scientific Corporation
- Cedars-Sinai Medical Center
- Abiomed
- National Institutes of Health
- Abbott Vascular
- National Heart, Lung, and Blood Institute (U01 HL-69015, R01-HL10583, R01HL105853, U01HL069015, U01-HL69013, U01HL069013)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- left ventricular ejection fraction, intermodality agreement, echocardiography, gated SPECT, cardiovascular magnetic resonance, left ventricular dysfunction, coronary artery disease, ischemic heart failure, STICH trial, measurement variability, mortality prediction, heart failure risk stratification, heart failure with reduced ejection fraction, heart failure with preserved ejection fraction
- MeSH terms
- Coronary Artery Disease, Echocardiography, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Stroke Volume, Ventricular Dysfunction, Left, Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography, Cardiac Imaging Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review