Outputting Olfactory Bionic Electric Impulse by PANI/PTFE/PANI Sandwich Nanostructures and their Application as Flexible, Smelling Electronic Skin
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A new flexible smelling electronic skin (e‐skin) has been realized from PANI(polyaniline)/PTFE(polytetrafluoroethylene)/PANI sandwich nanostructures basing on the triboelectrification/gas‐sensing coupling effect. The e‐skin can be driven by human motion/breath and efficiently convert mechanical vibration into electric impulse. And the output current/voltage is significantly dependent on the environmental atmosphere (volatile organic compounds in air), which can act as olfactory bionic electric impulse. Taking ethanol gas as an example, the detection limit of the e‐skin at room temperature is 30 ppm, and the response is up to 66.8 upon exposure to 210 ppm ethanol. Interestingly, the response of the e‐skin keeps stable with different dimensional sizes or under different strains/bending status. The working mechanism can be ascribed to the coupling of triboelectrification effect and surface reaction at the interfaces. Furthermore, an application of the flexible smelling e‐skin for visually identifying drunken driver without any external electricity power has been demonstrated. The results can open a possible new direction for the development of specialized‐function e‐skin and will further expand the scope for self‐powered nanosystems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Piezoelectricity of single-atomic-layer MoS2 for energy conversion and piezotronics
Wu, W., Wang, L., Li, Y., Zhang, F., Lin, L., Niu, S., Chenet, D., Zhang, X., Hao, Y., Heinz, T. F., et al. (2014) · Nature · doi:10.1038/nature13792 · Cited by 2,287
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
A skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Zhu, G., Su, Y., Bai, P., Chen, J., Jing, Q., Yang, W., & Wang, Z. L. (2014) · ACS Nano · doi:10.1021/nn5012732 · Cited by 565
Epidermal Electronics with Advanced Capabilities in Near-Field Communication
Kim, J., Banks, A., Cheng, H., Xie, Z., Xu, S., Jang, K.-I., Lee, J. W., Liu, Z., Gutruf, P., Huang, X., et al. (2015) · Small · doi:10.1002/smll.201402495 · Cited by 274
Zheng, Y., Cheng, L., Yuan, M., Wang, Z., Zhang, L., Qin, Y., & Jing, T. (2014) · Nanoscale · doi:10.1039/c4nr01934b · Cited by 250
Cited by
Recent advances in energy-saving chemiresistive gas sensors: A review
Majhi, S. M., Mirzaei, A., Kim, H. W., Kim, S. S., & Kim, T. W. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105369 · Cited by 653
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Material aspects of triboelectric energy generation and sensors
Kim, D. W., Lee, J. H., Kim, J. K., & Jeong, U. (2020) · NPG Asia Materials · doi:10.1038/s41427-019-0176-0 · Cited by 428
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Electronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Metadata
- Authors
- Xue, X., Fu, Y., Wang, Q., Xing, L., & Zhang, Y.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2016-02-29
- Volume
- 26
- Issue
- 18
- Pages
- 3128-3138
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2292461552
- Cited by
- 117
- References
- 14
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.