Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Anti‐liquid‐Interfering and Bacterially Antiadhesive Strategy for Highly Stretchable and Ultrasensitive Strain Sensors Based on Cassie‐Baxter Wetting State

Lin, Jing, Cai, Xianfang, Liu, Zili, Liu, Nan, Xie, Min, Zhou, BingPu, Wang, Huaquan, Guo, Zhanhu·2020·Advanced Functional Materials

Abstract

As a large number of strain sensors are put into practical use, their stability should be considered, especially in harsh environments containing water or microorganisms, which could affect strain sensing. Herein, a novel strategy to overcome liquid interference is proposed. The strain sensor is constructed with a sandwich architecture through layer‐by‐layer (LBL) spray‐coating of a 3‐(aminopropyl)triethoxysilane (APTES) bonding layer and multi‐walled carbon nanotubes/graphene (MWCNT/G) conductive layers on an elastomeric polydimethysiloxane (PDMS) substrate, and is further decorated with silver (Ag) nanoparticles and the (heptadecafluoro‐1,1,2,2‐tetradecyl) trimethoxysilane (FAS, F in short) to obtain a F/Ag/MWCNG/G‐PDMS (FAMG) strain sensor. The superhydrophobicity and underwater oleophobicity of the outer cover layer causes this FAMG strain sensor surface to exhibit stable strain sensing resistant to liquid interference upon stretching in the Cassie−Baxter wetting state, and resistance to bacterial adhesion (Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli)). The sensor attains ultrasensitivity (with a maximum gauge factor of 1989 in the condition of liquid interference), broad strain range (0.1–170%), fast response time (150 ms), and stable response after 1000 stretching–releasing cycles. The ultrasensitivity is provided by propagation of cracks in MWCNT/G conductive layers and terminal fracture of the intermediate separating layers (APTES/MWCNT/G). The microbridge effect of MWCNTs and slippage of APTES/MWCNT/G provide a large strain range. The FAMG strain sensor is successfully used to monitor a series of human activities and an electronic bird under artificial rain and bacterial droplets, indicating the potential use of this sensor in complex environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.202000398

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 251

Metadata

Authors
Lin, J., Cai, X., Liu, Z., Liu, N., Xie, M., Zhou, B., Wang, H., & Guo, Z.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2020-04-13
Volume
30
Issue
23
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W3016296474
Cited by
251
References
6
FWCI
12.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anti‐liquid‐Interfering and Bacterially Antiadhesive Strategy for Highly Stretchable and Ultrasensitive Strain Sensors Based on Cassie‐Baxter Wetting State. https://app.cochat.ai/papers/10.1002/adfm.202000398
The paper
Lin, J., Cai, X., Liu, Z., Liu, N., Xie, M., Zhou, B., Wang, H., & Guo, Z. (2020). Anti‐liquid‐Interfering and Bacterially Antiadhesive Strategy for Highly Stretchable and Ultrasensitive Strain Sensors Based on Cassie‐Baxter Wetting State. Advanced Functional Materials. https://doi.org/10.1002/adfm.202000398

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.