The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Gelatin Methacryloyl‐Based Tactile Sensors for Medical Wearables
Open accessAbstract
Gelatin methacryloyl (GelMA) is a widely used hydrogel with skin‐derived gelatin acting as the main constituent. However, GelMA has not been used in the development of wearable biosensors, which are emerging devices that enable personalized healthcare monitoring. This work highlights the potential of GelMA for wearable biosensing applications by demonstrating a fully solution‐processable and transparent capacitive tactile sensor with microstructured GelMA as the core dielectric layer. A robust chemical bonding and a reliable encapsulation approach are introduced to overcome detachment and water‐evaporation issues in hydrogel biosensors. The resultant GelMA tactile sensor shows a high‐pressure sensitivity of 0.19 kPa−1 and one order of magnitude lower limit of detection (0.1 Pa) compared to previous hydrogel pressure sensors owing to its excellent mechanical and electrical properties (dielectric constant). Furthermore, it shows durability up to 3000 test cycles because of tough chemical bonding, and long‐term stability of 3 days due to the inclusion of an encapsulation layer, which prevents water evaporation (80% water content). Successful monitoring of various human physiological and motion signals demonstrates the potential of these GelMA tactile sensors for wearable biosensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Synthesis, properties, and biomedical applications of gelatin methacryloyl (GelMA) hydrogels
Yue, K., Trujillo-de Santiago, G., Alvarez, M. M., Tamayol, A., Annabi, N., & Khademhosseini, A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.045 · Cited by 3,146
Self-citationCell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377
Self-citationSchwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Skin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035
Loessner, D., Meinert, C., Kaemmerer, E., Martine, L. C., Yue, K., Levett, P. A., Klein, T. J., Melchels, F. P. W., Khademhosseini, A., & Hutmacher, D. W. (2016) · Nature Protocols · doi:10.1038/nprot.2016.037 · Cited by 868
Self-citationWang, J., Jiu, J., Nogi, M., Sugahara, T., Nagao, S., Koga, H., He, P., & Suganuma, K. (2015) · Nanoscale · doi:10.1039/c4nr06494a · Cited by 293
Cited by
Feng, Y., Liu, H., Zhu, W., Guan, L., Yang, X., Zvyagin, A. V., Zhao, Y., Shen, C., Yang, B., & Lin, Q. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202105264 · Cited by 403
Self-citationBiomedical applications of gelatin methacryloyl hydrogels
Piao, Y., You, H., Xu, T., Bei, H.-P., Piwko, I. Z., Kwan, Y. Y., & Zhao, X. (2021) · Engineered Regeneration · doi:10.1016/j.engreg.2021.03.002 · Cited by 295
Self‐Healing Hydrogel Bioelectronics
Li, Z., Lu, J., Ji, T., Xue, Y., Zhao, L., Zhao, K., Jia, B., Wang, B., Wang, J., Zhang, S., et al. (2024) · Advanced Materials · doi:10.1002/adma.202306350 · Cited by 257
Self-citationDecellularization for the retention of tissue niches
Moffat, D., Ye, K., & Jin, S. (2022) · Journal of Tissue Engineering · doi:10.1177/20417314221101151 · Cited by 152
Adopting wearables to customize health insurance contributions: a ranking-type Delphi
Neumann, D., Tiberius, V., & Biendarra, F. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-01851-4 · Cited by 10
Metadata
- Authors
- Li, Z., Zhang, S., Chen, Y., Ling, H., Zhao, L., Luo, G., Wang, X., Hartel, M. C., Liu, H., Xue, Y., Haghniaz, R., Lee, K., Sun, W., Kim, H., Lee, J., Zhao, Y., Zhao, Y., Emaminejad, S., Ahadian, S., Ashammakhi, N., Dokmeci, M. R., Jiang, Z., & Khademhosseini, A.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-09-06
- Volume
- 30
- Issue
- 49
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3083309527
- Cited by
- 235
- References
- 10
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gelatin Methacryloyl‐Based Tactile Sensors for Medical Wearables. https://app.cochat.ai/papers/10.1002/adfm.202003601
- The paper
- Li, Z., Zhang, S., Chen, Y., Ling, H., Zhao, L., Luo, G., Wang, X., Hartel, M. C., Liu, H., Xue, Y., Haghniaz, R., Lee, K., Sun, W., Kim, H., Lee, J., Zhao, Y., Zhao, Y., Emaminejad, S., Ahadian, S., . . . Khademhosseini, A. (2020). Gelatin Methacryloyl‐Based Tactile Sensors for Medical Wearables. Advanced Functional Materials. https://doi.org/10.1002/adfm.202003601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.