The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Capacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Open accessAbstract
Integration of capacitive sensing capabilities to epidermal electronic systems (EES) can enhance the robustness in operation for electrophysiological signal measurement. Capacitive EES designs are reusable, electrically safe, and minimally sensitive to motion artifacts. Experiments on human subjects illustrate levels of fidelity in ECG, EMG, and EOG recordings comparable to those of standard gel electrodes and of direct contact EES electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The capacitive electrodes do not form direct electrical contact with skin, which makes them reusable, electrically safe and free from irritating the skin.[99]”
From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [99]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationHighly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,069
Medical instrumentation: Application and design
Undar, A., Calhoon, J., & da Rocha, A. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,019
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2008) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
A Multifunctional Capacitive Sensor for Stretchable Electronic Skins
Cotton, D. P. J., Graz, I. M., & Lacour, S. P. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030709 · Cited by 262
Liao, L., Wang, I.-J., Chen, S.-F., Chang, J., & Lin, C. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
Flexible-foam-based capacitive sensor arrays for object detection at low cost
Metzger, C., Fleisch, E., Meyer, J. T., Dansachmüller, M., Graz, I. M., Kaltenbrunner, M., Keplinger, C., Schwödiauer, R., & Bauer, S. (2008) · Applied Physics Letters · doi:10.1063/1.2830815 · Cited by 172
Recent advances in high-k nanocomposite materials for embedded capacitor applications
Lu, J., & Wong, C. (2008) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2008.4656240 · Cited by 170
Flagged first, then by citations
Research works printed but not linked: 7
- Yama Y., 2007, IEEE EMBS
- Torres F., 2009, Clin. Cosmet. Investig. Dermatol., 2, 39
- Wolfson R. N., 1969, 22nd ACEMB
- Lee S. M., 2013, J. Neural. Eng., 10, 1
- Ueno A., 2012, Sens. Mater., 24, 335
- Matthews R., 2007, IEEE EMBS
- Jeong J.‐W., 2013, Adv. Mater.
Cited by
Sorted by citations
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Self-citationWearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationSkin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationFlexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,096
Metadata
- Authors
- Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Northwestern University (US)
- Corresponding author
- Rogers, John A.
- ORCID
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2013-10-16
- Volume
- 3
- Issue
- 5
- Pages
- 642-648
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2065304780
- Cited by
- 288
- References
- 19
- Citations by year
- 2026: 10 · 2025: 16 · 2024: 21 · 2023: 14 · 2022: 22 · 2021: 26 · 2020: 37 · 2019: 32 · 2018: 26 · 2017: 32 · 2016: 25 · 2015: 18 · 2014: 9
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- National Science Foundation (DE-FG02-07ER46453, DE-FG02-07ER46471, 0328162)
- U.S. Department of Energy (DE‐FG02‐, FG02-07ER46453, DEFG0207ER46471, DEFG0207ER46453, FG02-07ER46471)
- University of Illinois at Urbana-Champaign
- Division of Materials Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- epidermal electronics, capacitive sensing, electrocardiogram, electromyography, electrooculography, motion artifacts, long-term monitoring, wearable sensors
- MeSH terms
- Electrodes, Electrodiagnosis, Epidermis, Equipment Design, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review