Bright AIE Nanoparticles with F127 Encapsulation for Deep‐Tissue Three‐Photon Intravital Brain Angiography
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Deep‐tissue imaging is of great significance to biological applications. In this paper, a deep‐red emissive luminogen 2,3‐bis(4′‐(diphenylamino)‐[1,1′‐biphenyl]‐4‐yl) fumaronitrile (TPATCN) with aggregation‐induced emission (AIE) feature is prepared. TPATCN molecules were then encapsulated within a polymeric matrix of Pluronic F‐127 to form nanoparticles (NPs). TPATCN NPs exhibit bright three‐photon fluorescence (3PF) in deep‐red region, together with high chemical stability, good photostability, and biocompatibility. They are further utilized for in vivo 3PF imaging of the brain vasculature of mice, under the excitation of a 1550 nm femtosecond laser. A vivid 3D reconstruction of the brain vasculature is then built with a penetration depth of 875 µm, which is the largest in ever reported 3PF imaging based on AIE NPs. After that, by collecting both of the 3PF and third‐harmonic generation signals, multichannel nonlinear optical imaging of the brain blood vessels is further realized. These results will be helpful to study the structures and functions of the brain in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Specific light-up bioprobes based on AIEgen conjugates
Liang, J., Tang, B. Z., & Liu, B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00444b · Cited by 762
High‐Order Non‐Linear Optical Effects in Organic Luminogens with Aggregation‐Induced Emission
Qian, J., Zhu, Z., Qin, A., Qin, W., Chu, L., Cai, F., Zhang, H., Wu, Q., Hu, R., Tang, B. Z., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500141 · Cited by 108
Self-citation
Cited by
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Self-citationWang, Y., Chen, M., Alifu, N., Li, S., Qin, W., Qin, A., Tang, B. Z., & Qian, J. (2017) · ACS Nano · doi:10.1021/acsnano.7b05645 · Cited by 177
Self-citationWang, S., Liu, J., Goh, C. C., Ng, L. G., & Liu, B. (2019) · Advanced Materials · doi:10.1002/adma.201904447 · Cited by 148
Wang, S., Liu, J., Feng, G., Ng, L. G., & Liu, B. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808365 · Cited by 110
Piwoński, H., Nozue, S., & Habuchi, S. (2022) · ACS Nanoscience Au · doi:10.1021/acsnanoscienceau.1c00038 · Cited by 39
Metadata
- Authors
- Wang, Y., Han, X., Xi, W., Li, J., Roe, A. W., Lu, P., & Qian, J.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-08-10
- Volume
- 6
- Issue
- 21
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2743953554
- Cited by
- 72
- References
- 4
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bright AIE Nanoparticles with F127 Encapsulation for Deep‐Tissue Three‐Photon Intravital Brain Angiography. https://app.cochat.ai/papers/10.1002/adhm.201700685
- The paper
- Wang, Y., Han, X., Xi, W., Li, J., Roe, A. W., Lu, P., & Qian, J. (2017). Bright AIE Nanoparticles with F127 Encapsulation for Deep‐Tissue Three‐Photon Intravital Brain Angiography. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201700685
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.