Microfluidic Tumor–Vascular Model to Study Breast Cancer Cell Invasion and Intravasation
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Cancer is a major leading cause of disease‐related death in the world. The severe impact of cancer can be attributed to poor understanding of the mechanisms involved in earliest steps of the metastatic cascade, specifically invasion into the surrounding stroma and intravasation into the blood capillaries. However, conducting integrated biological studies of invasion and intravasation have been challenging, within in vivo models and traditional in vitro assay, due to difficulties in establishing a precise tumor microenvironment. To that end, in this work, a novel 3D microfluidic platform comprised of concentric three‐layer cell‐laden hydrogels for simultaneous investigation of breast cancer cell invasion and intravasation as well as vasculature maturation influenced by tumor–vascular crosstalk is developed. It was demonstrated that the presence of spontaneously formed vasculature enhance MDA‐MB‐231 invasion into the 3D stroma. Following invasion, cancer cells are visualized intravasating into the outer vasculature. Additionally, invading cancer cells significantly reduce vessel diameter while increasing permeability, consistent with previous in vivo studies. Major signaling cytokines involved in tumor–vascular crosstalk that govern cancer cell invasion and intravasation are further identified. Taken together, this platform will enable unique insights of critical biological events within the metastatic cascade, with significant potential for developing efficient cancer therapeutics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“First, HUVECs form a leakier barrier than brain endothelial cells.[ 147 , 149 ]”
From 3D Biomimetic Models to Reconstitute Tumor Microenvironment In Vitro: Spheroids, Organoids, and Tumor‐on‐a‐Chip (2023) · cites this paper as [149]
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Basic and Therapeutic Aspects of Angiogenesis
Potente, M., Gerhardt, H., & Carmeliet, P. (2011) · Cell · doi:10.1016/j.cell.2011.08.039 · Cited by 2,771
Nishida, N., Yano, H., Nishida, T., Kamura, T., & Kojiro, M. (2006) · Vascular Health and Risk Management · doi:10.2147/vhrm.2006.2.3.213 · Cited by 1,434
Bussolino, F., Di Renzo, M. F., Ziche, M., Bocchietto, E., Olivero, M., Naldini, L., Gaudino, G., Tamagnone, L., Coffer, A., & Comoglio, P. M. (1992) · The Journal of cell biology · doi:10.1083/jcb.119.3.629 · Cited by 1,337
Multistep Nature of Metastatic Inefficiency
Luzzi, K. J., MacDonald, I. C., Schmidt, E. E., Kerkvliet, N., Morris, V. L., Chambers, A. F., & Groom, A. C. (1998) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65628-3 · Cited by 1,243
TGFβ Primes Breast Tumors for Lung Metastasis Seeding through Angiopoietin-like 4
Padua, D., Zhang, X. H.-F., Wang, Q., Nadal, C., Gerald, W. L., Gomis, R. R., & Massagué, J. (2008) · Cell · doi:10.1016/j.cell.2008.01.046 · Cited by 952
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Human 3D vascularized organotypic microfluidic assays to study breast cancer cell extravasation
Jeon, J. S., Bersini, S., Gilardi, M., Dubini, G., Charest, J. L., Moretti, M., & Kamm, R. D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1417115112 · Cited by 723
Vascular permeability, vascular hyperpermeability and angiogenesis
Nagy, J. A., Benjamin, L., Zeng, H., Dvorak, A. M., & Dvorak, H. F. (2008) · Angiogenesis · doi:10.1007/s10456-008-9099-z · Cited by 628
Weis, S., Cui, J., Barnes, L., & Cheresh, D. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200408130 · Cited by 477
Research works printed but not linked: 5
- Ahadian S., 2017, Adv. Healthcare Mater.
- Peela N., 2016, 20th Int. Conf. Miniaturized Systems for Chemistry and Life Sciences
- Doillon C. J., 2004, Anticancer Res., 24, 2169
- Huang W., 2014, Int. J. Clin. Exp. Pathol., 7, 8506
- Shaughnessy S. G., 1991, Am. J. Pathol., 138, 1535
Cited by
Biomedical Applications of Microfluidic Devices: A Review
Gharib, G., Bütün, İ., Muganlı, Z., Kozalak, G., Namlı, İ., Sarraf, S. S., Ahmadi, V. E., Toyran, E., van Wijnen, A. J., & Koşar, A. (2022) · Biosensors · doi:10.3390/bios12111023 · Cited by 215
Trujillo-de Santiago, G., Flores-Garza, B. G., Tavares-Negrete, J. A., Lara-Mayorga, I. M., González-Gamboa, I., Zhang, Y. S., Rojas-Martínez, A., Ortiz-López, R., & Álvarez, M. M. (2019) · Materials · doi:10.3390/ma12182945 · Cited by 184
“[30,56,62,65-68,70-72,85,189-192] [22,23,29,32,43,50,5559,63,64,165,177,194] [21,27,28,47,64]”
Truong, D., Fiorelli, R., Barrientos, E. S., Melendez, E. L., Sanai, N., Mehta, S., & Nikkhah, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.048 · Cited by 150
“This model also overcomes the limitation of prior work by introducing patient-derived GSCs after formation of the microvascular network instead of introducing both cell-types at the same time [39].”
InfluentialSelf-citationTruong, D. D., Kratz, A., Park, J. G., Barrientos, E. S., Saini, H., Nguyen, T., Pockaj, B., Mouneimne, G., LaBaer, J., & Nikkhah, M. (2019) · Cancer Research · doi:10.1158/0008-5472.can-18-2293 · Cited by 149
“Microfluidic models integrated with hydrogel-based 3D matrices allow the study of different steps of the metastatic cascade such as invasion, intravasation, and extravasation[7-11].”
BackgroundSelf-citationApplications of Microfluidics and Organ-on-a-Chip in Cancer Research
Regmi, S., Poudel, C., Adhikari, R., & Luo, K. Q. (2022) · Biosensors · doi:10.3390/bios12070459 · Cited by 143
Lai, B. F. L., Lu, R. X. Z., Hu, Y., Davenport Huyer, L., Dou, W., Wang, E. Y., Radulovich, N., Tsao, M. S., Sun, Y., & Radisic, M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000545 · Cited by 142
Endothelial Regulation of Drug Transport in a 3D Vascularized Tumor Model
Haase, K., Offeddu, G. S., Gillrie, M. R., & Kamm, R. D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202002444 · Cited by 127
3D models in the new era of immune oncology: focus on T cells, CAF and ECM
Modugno, F. D., Colosi, C., Trono, P., Antonacci, G., Ruocco, G., & Nisticò, P. (2019) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-019-1086-2 · Cited by 121
“The distinctive value offered by microfluidic culture is the presence of accessible fluidic control that is particularly effective in mimicking the vasculature component of TME, offering the possibility to induce flow-related instructions to cells [113], model invasion [114, 115], neovascularization [116, 117], metast…”
Li, W., Zhou, Z., Zhou, X., Khoo, B. L., Gunawan, R., Chin, Y. R., Zhang, L., Yi, C., Guan, X., & Yang, M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202609 · Cited by 119
3D Bioprinting of Tumor Models for Cancer Research
Kang, Y., Datta, P., Shanmughapriya, S., & Ozbolat, I. T. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00791 · Cited by 112
Engineering Precision Medicine
Sun, W., Lee, J., Zhang, S., Benyshek, C., Dokmeci, M. R., & Khademhosseini, A. (2018) · Advanced Science · doi:10.1002/advs.201801039 · Cited by 103
Engineering anisotropic human stem cell-derived three-dimensional cardiac tissue on-a-chip
Veldhuizen, J., Cutts, J., Brafman, D. A., Migrino, R. Q., & Nikkhah, M. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120195 · Cited by 98
Self-citationVeldhuizen, J., Chavan, R., Moghadas, B., Park, J. G., Kodibagkar, V. D., Migrino, R. Q., & Nikkhah, M. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121336 · Cited by 99
Self-citationMicrofluidics meets 3D cancer cell migration
Mehta, P., Rahman, Z., ten Dijke, P., & Boukany, P. E. (2022) · Trends in cancer · doi:10.1016/j.trecan.2022.03.006 · Cited by 85
Breast tumor-on-chip models: From disease modeling to personalized drug screening
Bano, S., Dahiya, U. R., Mishra, S., Ayache, J., Casquillas, G. V., Caballero, D., Reis, R. L., & Kundu, S. C. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.12.057 · Cited by 83
Vessel-on-a-chip models for studying microvascular physiology, transport, and function in vitro
Moses, S. R., Adorno, J. J., Palmer, A. F., & Song, J. W. (2020) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00355.2020 · Cited by 81
Kumar, V., & Varghese, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801198 · Cited by 68
Recapitulating the vasculature using ORGAN-ON-CHIP technology
Pollet, A. M. A. O., & den Toonder, J. M. J. (2020) · Bioengineering · doi:10.3390/bioengineering7010017 · Cited by 73
Kim, D., Hwang, K. S., Seo, E. U., Seo, S., Lee, B. C., Choi, N., Choi, J., & Kim, H. N. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102581 · Cited by 63
Emerging tumor-on-chips with electrochemical biosensors
Lei, L., Ma, B., Xu, C., & Liu, H. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116640 · Cited by 72
Adjei‐Sowah, E., O’Connor, S. A., Veldhuizen, J., Cascio, C. L., Plaisier, C. L., Mehta, S. V., & Nikkhah, M. (2022) · Advanced Science · doi:10.1002/advs.202201436 · Cited by 69
Self-citationVascularized microfluidic platforms to mimic the tumor microenvironment
Michna, R. J., Gadde, M., Özkan, A., DeWitt, M. R., & Rylander, M. N. (2018) · Biotechnology and Bioengineering · doi:10.1002/bit.26778 · Cited by 67
“…Ingber, 2014; Bischel, Young, Mader, & Beebe, 2013; Farahat et al., 2012; Ghousifam et al., 2017; Jeon et al., 2015; Lee et al., 2014; Mi et al., 2016; Nagaraju et al., 2018; Peela et al., 2017; Price et al., 2008; Soleimani et al., 2018; Song et al., 2009; Y. Ma et al., 2018; Zheng et al., 2012).”
3D Cancer Models: Depicting Cellular Crosstalk within the Tumour Microenvironment
Franchi-Mendes, T., Eduardo, R., Domenici, G., & Brito, C. (2021) · Cancers · doi:10.3390/cancers13184610 · Cited by 68
Biofabrication Strategies and Engineered In Vitro Systems for Vascular Mechanobiology
Pradhan, S., Banda, O. A., Farino, C. J., Sperduto, J. L., Keller, K. A., Taitano, R. A., & Slater, J. H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901255 · Cited by 65
Saha, B., Mathur, T., Handley, K. F., Hu, W., Afshar-Kharghan, V., Sood, A. K., & Jain, A. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020001632 · Cited by 63
The Variety of 3D Breast Cancer Models for the Study of Tumor Physiology and Drug Screening
Fröhlich, E. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24087116 · Cited by 57
Sampaio, A. R., Maia, R., Ciardulli, M. C., Santos, H. A., & Sarmento, B. F. C. C. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102053 · Cited by 58
“[90].”
Three‐dimensional microfluidic tumor–macrophage system for breast cancer cell invasion
Mi, S., Liu, Z., Du, Z., Yi, X., & Sun, W. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26961 · Cited by 56
Cancer-on-a-chip for precision cancer medicine
Liu, L., Wang, H., Chen, R., Song, Y., Wei, W., Baek, D. S. H., Gillin, M., Kurabayashi, K., & Chen, W. (2025) · Lab on a Chip · doi:10.1039/d4lc01043d · Cited by 52
Dendritic cell vaccine for the effective immunotherapy of breast cancer
Jiang, N., Song, J., Wang, B., Hua, H., Zhu, H., Guo, X., Xiong, S., & Zhao, Y. (2020) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2020.110046 · Cited by 51
Saini, H., Rahmani Eliato, K., Veldhuizen, J., Zare, A., Allam, M., Silva, C., Kratz, A., Truong, D., Mouneimne, G., LaBaer, J., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119975 · Cited by 47
Self-citationEngineering Breast Cancer On-chip—Moving Toward Subtype Specific Models
Moccia, C., & Haase, K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.694218 · Cited by 51
Humayun, M., Ayuso, J. M., Brenneke, R. A., Virumbrales-Muñoz, M., Lugo-Cintrón, K., Kerr, S., Ponik, S. M., & Beebe, D. J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120640 · Cited by 46
Ravi, K., Manoharan, T. J. M., Wang, K.-C., Pockaj, B. A., & Nikkhah, M. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122428 · Cited by 47
Self-citationMulti-organ-on-chip approach in cancer research
Żuchowska, A., & Skorupska, S. (2021) · Organs-on-a-Chip · doi:10.1016/j.ooc.2021.100014 · Cited by 46
van Tienderen, G. S., Koerkamp, B. G., IJzermans, J. N. M., van der Laan, L. J. W., & Verstegen, M. M. A. (2019) · Cancers · doi:10.3390/cancers11111706 · Cited by 44
Cancer Metastasis‐on‐a‐Chip for Modeling Metastatic Cascade and Drug Screening
Brooks, A., Zhang, Y., Chen, J., & Zhao, C. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302436 · Cited by 44
Pal, A., Smith, C. I., Palade, J., Nagaraju, S., Alarcon-Benedetto, B. A., Kilbourne, J. A., Rawls, A., Wilson‐Rawls, J., Vernon, B. L., & Nikkhah, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.041 · Cited by 43
Self-citationAngeli, S., Neophytou, C., Kalli, M., Stylianopoulos, T., & Mpekris, F. (2025) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2025.1564626 · Cited by 42
“…recreate and analyze the complex mechanical and biochemical conditions of the TME in highly controlled settings, providing valuable insights into cell migration, invasion and treatment resistance (Mehta et al., 2022; Hou et al., 2009; Lee H. et al., 2014; Nagaraju et al., 2018; Yang et al., 2022).”
Karamanova, N., Truran, S., Serrano, G. E., Beach, T. G., Madine, J., Weissig, V., Davies, H. A., Veldhuizen, J., Nikkhah, M., Hansen, M., et al. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.014810 · Cited by 41
Self-citationOn-Chip Replication of Extremely Early-Stage Tumor Behavior
Li, C., Li, S., Du, K., Li, P., Qiu, B., & Ding, W. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c03740 · Cited by 40
Three‑dimensional models to study breast cancer (Review)
Huerta‐Reyes, M., & Aguilar‐Rojas, A. (2021) · International Journal of Oncology · doi:10.3892/ijo.2021.5176 · Cited by 39
Engineered in vitro tumor models for cell-based immunotherapy
Ando, Y., Mariano, C. F., & Shen, K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.03.076 · Cited by 39
Wu, Y., Zhou, Y., Paul, R., Qin, X., Islam, K., & Liu, Y. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02556 · Cited by 39
On-chip modeling of tumor evolution: Advances, challenges and opportunities
Li, C., Holman, J. B., Shi, Z., Qiu, B., & Ding, W. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100724 · Cited by 39
“[97], Copyright 2018 Wiley); (D) chip structure and (E)”
BackgroundAzadi, S., Tafazzoli‐Shadpour, M., & Warkiani, M. E. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27612 · Cited by 38
“To confirm the integrity of a confluent EC layer, the diffusive permeability was assessed with fluorescently labeled dextran (70 kDa; Sigma‐Aldrich) as the previously published protocol (Nagaraju et al., 2018).”
MethodSaini, H., Rahmani Eliato, K., Silva, C., Allam, M., Mouneimne, G., Ros, R., & Nikkhah, M. (2018) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-018-0544-9 · Cited by 37
Self-citationThree-Dimensional in Vitro Models: A Promising Tool To Scale-Up Breast Cancer Research
Azimian, V., Rafiee, L., Sheikholeslam, M., Shariati, L., Vaseghi, G., Savoji, H., & Javanmard, S. H. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00277 · Cited by 36
Zhao, L., Mok, S., & Moraes, C. (2019) · Biofabrication · doi:10.1088/1758-5090/ab30b4 · Cited by 35
Recent advances in vascularized tumor-on-a-chip
Huang, C. B. X., & Tu, T.-Y. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1150332 · Cited by 34
Biomimetic Microfluidic Platforms for the Assessment of Breast Cancer Metastasis
Sigdel, I., Gupta, N. K., Faizee, F., Khare, V. M., Tiwari, A. K., & Tang, Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.633671 · Cited by 34
“, 2019), intravasation (Cui et al., 2017; Nagaraju et al., 2018; Shirure et al., 2018), extravasation (Chen M.”
The impact of pericytes on the stability of microvascular networks in response to nanoparticles
Dibble, M., Ciò, S. D., Luo, P., Balkwill, F. R., & Gautrot, J. E. (2023) · Scientific Reports · doi:10.1038/s41598-023-31352-x · Cited by 34
The biomechanical signature of tumor invasion
Liu, C. B., Wang, S., Zhang, X., Han, Y., Tan, M., Fan, J., Du, J., Fan, Y., & Zhao, X. (2025) · Genes & Diseases · doi:10.1016/j.gendis.2025.101771 · Cited by 33
Wang, R., Zhang, C., Li, D., & Yao, Y. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1057913 · Cited by 34
Recent advances in lab-on-a-chip systems for breast cancer metastasis research
Yildirir, B. F., Yalcin-Ozuysal, Ö., & Nonappa, N. (2023) · Nanoscale Advances · doi:10.1039/d2na00823h · Cited by 34
Kim, S., Ko, J., Lee, B., Park, D., Park, S., & Jeon, N. L. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27765 · Cited by 32
“migration capacity of cancer cells is different for each type of cancer cells.(Kubens & Zanker, 1998; Nagaraju et al., 2018) As shown in Figure 1b, we applied 3′′ × 1′′ glass slide and 96‐well plate design for high‐throughput screening of vasculature assay.”
MethodEngineering strategies to capture the biological and biophysical tumor microenvironment in vitro
Tan, M. L., Lu, L., & Fischbach, C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113852 · Cited by 32
Use and application of organ-on-a-chip platforms in cancer research
Yu, Y., Zhou, T., & Cao, L.-L. (2023) · Journal of Cell Communication and Signaling · doi:10.1007/s12079-023-00790-7 · Cited by 31
“Another 3D device, made from three concentric layers of cell-filled hydrogels that replicated tumor cell, stromal, and vascular networks was used to establish an intravasation model of breast cancer cells (Nagaraju et al. 2018).”
MethodApplication of Microfluidic Systems for Breast Cancer Research
Frankman, Z. D., Jiang, L., Schroeder, J. A., & Zohar, Y. (2022) · Micromachines · doi:10.3390/mi13020152 · Cited by 33
“The invading cancer cells significantly reduced vessel diameter while increasing permeability, and major signaling cytokines involved in tumor–vascular crosstalk governing cancer cell invasion and intravasation were identified [76].”
BackgroundRavi, K., Zhang, Y., Sakala, L., Manoharan, T. J. M., Pockaj, B. A., LaBaer, J., Park, J. G., & Nikkhah, M. (2025) · Advanced Science · doi:10.1002/advs.202413457 · Cited by 29
Self-citationSelf-assembled and perfusable microvasculature-on-chip for modeling leukocyte trafficking
Hirth, E., Cao, W., Peltonen, M., Kapetanovic, E., Dietsche, C. L., Svanberg, S., Filippova, M., Reddy, S. T., & Dittrich, P. S. (2024) · Lab on a Chip · doi:10.1039/d3lc00719g · Cited by 29
Breast cancer brain metastasis: from etiology to state-of-the-art modeling
Kamalabadi‐Farahani, M., Gharibshahian, M., Rezvani, A., & Vaez, A. (2023) · Journal of Biological Engineering · doi:10.1186/s13036-023-00352-w · Cited by 28
“Cancer cells that invaded the vessel drastically reduced its diameter while simultaneously increasing its permeability, and the primary signaling cytokines involved in tumor– vascular crosstalk that governs cancer cell invasion and intravasation were identified [218].”
BackgroundManoharan, T. J. M., Ravi, K., Suresh, A. P., Acharya, A. P., & Nikkhah, M. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303658 · Cited by 28
Self-citationMechanical deformation and death of circulating tumor cells in the bloodstream
Qiu, Y., Gao, T., & Smith, B. R. (2024) · Cancer and Metastasis Reviews · doi:10.1007/s10555-024-10198-3 · Cited by 27
“…tumors via experiments [124–128] and computational modeling [129–132]. b) Intravasation/extravasation across the blood vessel wall via experiments [133–137] and computational models [138, 139]. c) Studies of CTC circulation through blood vessels via experimental [114, 140] and computational…”
Microengineered 3D Tumor Models for Anti-Cancer Drug Discovery in Female-Related Cancers
Amirghasemi, F., Adjei‐Sowah, E., Pockaj, B. A., & Nikkhah, M. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02704-9 · Cited by 27
Self-citationRecent advances in cancer-on-a-chip tissue models to dissect the tumour microenvironment
Seaman, K., Sun, Y., & You, L. (2023) · Med-X · doi:10.1007/s44258-023-00011-1 · Cited by 26
“Cancer is an adaptive and dynamic disease mainly driven by the genetic mutation(s) of cells, resulting in uncontrolled cell proliferation and eventual invasion into other organs [1–3].”
BackgroundInfluentialVascularized tumor models for the evaluation of drug delivery systems: a paradigm shift
Lopez-Vince, E., Wilhelm, C., & Simón‐Yarza, T. (2024) · Drug Delivery and Translational Research · doi:10.1007/s13346-024-01580-3 · Cited by 26
“As its use became more standardized, its versatility was exploited across a spectrum of concentrations, ranging from 1.5 mg/ mL to 7 mg/mL [30–32].”
BackgroundInfluentialSima, F., Kawano, H., Hirano, M., Miyawaki, A., Obata, K., Serien, D., & Sugioka, K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000484 · Cited by 25
Millet, M., Messaoud, R. B., Luthold, C., & Bordeleau, F. (2019) · Micromachines · doi:10.3390/mi10060418 · Cited by 24
Shakouri, A., Kahroba, H., Hamishekar, H., & Abdolalizadeh, J. (2021) · Bioimpacts · doi:10.34172/bi.2021.39 · Cited by 23
Three-dimensional scaffold-free microtissues engineered for cardiac repair
Patino-Guerrero, A., Veldhuizen, J., Zhu, W., Migrino, R. Q., & Nikkhah, M. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb01528h · Cited by 23
Self-citationAbdollahiyan, P., Oroojalian, F., Baradaran, B., de la Guárdia, M., & Mokhtarzadeh, A. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.06.002 · Cited by 23
Zhou, L., Liu, L., Chang, M. A., Ma, C., Chen, W., & Chen, P. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115064 · Cited by 22
Engineering Patient-on-a-Chip Models for Personalized Cancer Medicine
Caballero, D., Reis, R. L., & Kundu, S. C. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-36588-2_4 · Cited by 22
Ghosh, L. D., Mathur, T., Tronolone, J. J., Chuong, A. B., Rangel, K., Corvigno, S., Sood, A. K., & Jain, A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304263 · Cited by 21
Recent advances in 3D models of tumor invasion
Shin, D. S., & Anseth, K. S. (2021) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2021.100310 · Cited by 21
Parisi, C., Qin, K., & Fernandes, F. M. (2021) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2020.0344 · Cited by 21
Tien, J., Dance, Y. W., Ghani, U., Seibel, A. J., & Nelson, C. M. (2020) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-020-00661-w · Cited by 20
The tumor microenvironment across four dimensions: assessing space and time in cancer biology
Larson, C. R., Mandloi, A., Acharyya, S., & Carstens, J. L. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1554114 · Cited by 19
“For instance, vascularizing TOC with micro fl uidics successfully models drug delivery, biochemical diffusion, and metastatic dynamics (148 – 151).”
Sun, Y., Wang, X., Xiao, M., Lv, S., Cheng, M., & Shi, F. (2021) · Langmuir · doi:10.1021/acs.langmuir.1c00266 · Cited by 18
Liu, T., Zhou, C., Ji, J., Xu, X., Xing, Z., Shinohara, M., Sakai, Y., Sun, T., Feng, X., Yu, Z., et al. (2023) · Biofabrication · doi:10.1088/1758-5090/ace3f9 · Cited by 18
“Nagaraju et al constructed a metastasis stage breast tumor model and demonstrated vasculature maturation influenced by tumor–vascular crosstalk in a 3D microfluidic chip [13].”
An in vitro model of cancer invasion with heterogeneous ECM created with droplet microfluidics
Jouybar, M., Sleeboom, J. J. F., Vaezzadeh, E., Sahlgren, C., & den Toonder, J. M. J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1267021 · Cited by 18
Komarnisky, R.-M., Wootten, S., Friedman, N., & Nikkhah, M. (2025) · Lab on a Chip · doi:10.1039/d5lc00426h · Cited by 17
Self-citationNgo, H. T., Amartumur, S., Tran, V. T. A., Tran, M., Diep, Y. N., Cho, H., & Lee, L. P. (2023) · Biosensors · doi:10.3390/bios13020231 · Cited by 17
“A breast tumor–stroma–vessel chip consisting of three distinct compartments was used to model intravasation (Figure 1e, 2018) [60].”
MethodWong, C. W. T., Lee, J. Z. X., Jaeschke, A., Ng, S. S. Y., Lit, K. K., Wan, H.-Y., Kniebs, C., Ker, D. F. E., Tuan, R. S., & Blocki, A. M. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.06.028 · Cited by 16
“This does not fully recapitulate the blood vessel anatomy and lacks crucial features of functional microvessels, such as good physiologically representative vascular barrier functions [22,27,32,33].”
Nagy, A. G., Székács, I., Bonyár, A., & Horváth, R. (2022) · Scientific Reports · doi:10.1038/s41598-022-14034-y · Cited by 16
Liu, Y., Liu, Y., Zheng, X. S., Zhao, L., & Zhang, X. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901713 · Cited by 16
Understanding organotropism in cancer metastasis using microphysiological systems
Ko, J., Song, J., Lee, Y., Choi, N., & Kim, H. N. (2024) · Lab on a Chip · doi:10.1039/d3lc00889d · Cited by 15
Baka, Z., Stiefel, M., Figarol, A., Godier, C., Mallick, A., Joubert, O., Ashammakhi, N. A., Gaffet, É., & Alem, H. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac8259 · Cited by 15
Blyth, R. R. R., Birts, C. N., & Beers, S. A. (2023) · Breast Cancer Research · doi:10.1186/s13058-023-01700-w · Cited by 15
“The vascular networks within the breast TME, supply nutrition and oxygen to the primary tumour, as well as aiding cancer cell invasion into the stroma and capillaries through a process known as intra-vasation [77].”
BackgroundEngineering approaches to studying cancer cell migration in three-dimensional environments
Zuela-Sopilniak, N., & Lammerding, J. (2019) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2018.0219 · Cited by 15
Unraveling Cancer Metastatic Cascade Using Microfluidics-based Technologies
Hakim, M., Kermanshah, L., Abouali, H., Hashemi, H. M., Yari, A., Khorasheh, F., Alemzadeh, I., & Vossoughi, M. (2022) · Biophysical Reviews · doi:10.1007/s12551-022-00944-8 · Cited by 15
“A recent study has addressed the current challenges by developing a physiologically relevant in vitro microdevice to model cell–cell and cell–ECM interactions (Nagaraju et al. 2018).”
BackgroundSpatial -omics technologies: the new enterprise in 3D breast cancer models
Pierantoni, L., Reis, R. L., Silva‐Correia, J., Oliveira, J. M., & Heavey, S. (2023) · Trends in biotechnology · doi:10.1016/j.tibtech.2023.07.003 · Cited by 16
Endothelial cells metabolically regulate breast cancer invasion toward a microvessel
Tan, M. L., Jenkins-Johnston, N., Huang, S., Schutrum, B. E., Vadhin, S., Adhikari, A., Williams, R. M., Zipfel, W. R., Lammerding, J., Varner, J. D., et al. (2023) · APL Bioengineering · doi:10.1063/5.0171109 · Cited by 15
Microfluidic Reconstitution of Tumor Microenvironment for Nanomedical Applications
Oh, H. J., Kim, J., Kim, H., Choi, N., & Chung, S. H. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002122 · Cited by 13
Application of microfluidic technology in cancer research and therapy
Azadi, S., Es, H. A., Kulasinghe, A., Bordhan, P., & Warkiani, M. E. (2020) · Advances in clinical chemistry · doi:10.1016/bs.acc.2020.02.012 · Cited by 12
Konopka, J., Żuchowska, A., & Jastrzębska, E. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115986 · Cited by 11
Recapitulating the Cancer‐Immunity Cycle on a Chip
Lee, Y., Min, J., Kim, S., Park, W., Ko, J., & Jeon, N. L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401927 · Cited by 11
Zhang, K., Du, Z., Yuan, T., Huang, J., Zhao, X., & Mi, S. (2022) · Biomicrofluidics · doi:10.1063/5.0090027 · Cited by 11
Biomaterials meet organ-on-chips – a perspective on tumor modeling
Monteiro, C. F., Deus, I. A., Custódio, C. A., & Mano, J. F. (2024) · International Materials Reviews · doi:10.1177/09506608241303436 · Cited by 10
“352,372,373 – 377 With the premise of recreating the distinct metastatic behavior of a bone tumor (in particular, osteosarcoma), Monteiro and colleagues developed a novel chip design to co-culture a tumor spheroid and dispersed hBM-MSCs in a fully-human environment, using a human PLMA hydrogel.”
Metadata
- Authors
- Nagaraju, S., Truong, D., Mouneimne, G., & Nikkhah, M.
- Affiliations
- Arizona State University (US)
- University of Arizona Cancer Center (US)
- Corresponding author
- Nikkhah, Mehdi
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-01-15
- Volume
- 7
- Issue
- 9
- Pages
- e1701257-e1701257
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2783342489
- Semantic Scholar
- 9039ef07dcd4d894784d8f72546768d52ed6b4f2
- Cited by
- 147
- References
- 58
- Citations by year
- 2026: 8 · 2025: 19 · 2024: 17 · 2023: 27 · 2022: 16 · 2021: 22 · 2020: 20 · 2019: 12 · 2018: 6
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (CBET 1510700, 2017–2018)
- Achievement Rewards for College Scientists Foundation (2016–2017)
- International Foundation for Ethical Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- breast cancer, tumor invasion, intravasation, metastasis, MDA-MB-231 cells, tumor microenvironment, vascular permeability, vessel diameter, cytokines, stroma
- MeSH terms
- Breast Neoplasms, Female, Humans, Models, Biological, Neoplasm Invasiveness, Neovascularization, Pathologic, Cell Line, Tumor, Microfluidic Analytical Techniques, Tumor Microenvironment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.