Two‐Layered and Stretchable e‐Textile Patches for Wearable Healthcare Electronics
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Wearable healthcare systems require skin‐adhering electrodes that allow maximal comfort for patients as well as an electronics system to enable signal processing and transmittance. Textile‐based electronics, known as “e‐textiles,” is a platform technology that allows comfort for patients. Here, two‐layered e‐textile patches are designed by controlled permeation of Ag‐particle/fluoropolymer composite ink into a porous textile. The permeated ink forms a cladding onto the nanofibers in the textile substrate, which is beneficial for mechanical and electrical properties of the e‐textile. The printed e‐textile features conductivity of ≈3200 S cm−1, whereas 1000 cycles of 30% uniaxial stretching causes the resistance to increase only by a factor of ≈5, which is acceptable in many applications. Controlling over the penetration depth enables a two‐layer design of the e‐textile, where the sensing electrodes and the conducting traces are printed in the opposite sides of the substrate. The formation of vertical interconnected access is remarkably simple as an injection from a syringe. With the custom‐developed electronic circuits, a surface electromyography system with wireless data transmission is demonstrated. Furthermore, the dry e‐textile patch collects electroencephalography with comparable signal quality to commercial gel electrodes. It is anticipated that the two‐layered e‐textiles will be effective in healthcare and sports applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G. (2015) · ACS Nano · doi:10.1021/acsnano.5b00599 · Cited by 770
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
Advanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Cited by
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Toward Flexible Surface‐Enhanced Raman Scattering (SERS) Sensors for Point‐of‐Care Diagnostics
Xu, K., Zhou, R., Takei, K., & Hong, M. (2019) · Advanced Science · doi:10.1002/advs.201900925 · Cited by 633
Mechanically Flexible Conductors for Stretchable and Wearable E‐Skin and E‐Textile Devices
Wang, B., & Facchetti, A. (2019) · Advanced Materials · doi:10.1002/adma.201901408 · Cited by 515
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Metadata
- Authors
- La, T., Qiu, S., Scott, D. K., Bakhtiari, R., Kuziek, J. W. P., Mathewson, K. E., Rieger, J., & Chung, H.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-10-19
- Volume
- 7
- Issue
- 22
- Pages
- e1801033-e1801033
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2896613591
- Cited by
- 124
- References
- 9
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐Layered and Stretchable e‐Textile Patches for Wearable Healthcare Electronics. https://app.cochat.ai/papers/10.1002/adhm.201801033
- The paper
- La, T., Qiu, S., Scott, D. K., Bakhtiari, R., Kuziek, J. W. P., Mathewson, K. E., Rieger, J., & Chung, H. (2018). Two‐Layered and Stretchable e‐Textile Patches for Wearable Healthcare Electronics. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201801033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.