3D Printing Silicone Elastomer for Patient‐Specific Wearable Pulse Oximeter
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Commercial pulse oximeters are used clinically to measure heart rate and blood oxygen saturation and traditionally made from rigid materials. However, these devices are unsuitable for continuous monitoring due to poor fit and mechanical mismatch. Soft materials that match the elastic properties of biological tissue provide improved comfort and signal‐to‐noise but typically require molding to manufacture, limiting the speed and ease of customizing for patient‐specific anatomy. Here, freeform reversible embedding (FRE) 3D printing is used to create polydimethylsiloxane (PDMS) elastomer cuffs for use on the hand and foot. FRE enables printing liquid PDMS prepolymer in 3D geometries within a sacrificial hydrogel bath that provides support during cure. This serves as proof‐of‐concept for fabricating patient‐specific pulse oximeters with pressure sensing, termed P 3‐wearable. A sizing analysis establishes dimensional accuracy of FRE‐printed PDMS compared to anatomical computer‐aided design models. The P 3‐wearable successfully outputs photoplethysmography (PPG) and pressure amplitude signals wirelessly to a tablet in real time and the PPG is used to calculate heart rate, blood oxygen content, and activity state. The results establish that FRE printing of PDMS can be used to fabricate patient‐specific wearable devices and measure heart rate and blood oxygenation on par with commercial devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
3D bioprinting of collagen to rebuild components of the human heart
Lee, A., Hudson, A. R., Shiwarski, D. J., Tashman, J. W., Hinton, T. J., Yerneni, S., Bliley, J. M., Campbell, P. G., & Feinberg, A. W. (2019) · Science · doi:10.1126/science.aav9051 · Cited by 1,782
Self-citationLab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Multifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
3D Printing PDMS Elastomer in a Hydrophilic Support Bath via Freeform Reversible Embedding
Hinton, T. J., Hudson, A., Pusch, K., Lee, A., & Feinberg, A. W. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00170 · Cited by 437
Self-citationHarada, S., Kanao, K., Yamamoto, Y., Arie, T., Akita, S., & Takei, K. (2014) · ACS Nano · doi:10.1021/nn506293y · Cited by 350
Pathology of Peripheral Artery Disease in Patients With Critical Limb Ischemia
Narula, N., Dannenberg, A. J., Olin, J. W., Bhatt, D. L., Johnson, K. W., Nadkarni, G., Min, J., Torii, S., Poojary, P., Anand, S. S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.002 · Cited by 326
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Comparison of nasal and forehead oximetry accuracy and pressure injury in critically ill patients
Schallom, M., Prentice, D., Sona, C., Arroyo, C., & Mazuski, J. (2018) · Heart & Lung · doi:10.1016/j.hrtlng.2017.12.002 · Cited by 30
Cited by
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
FRESH 3D Bioprinting a Full-Size Model of the Human Heart
Mirdamadi, E., Tashman, J. W., Shiwarski, D. J., Palchesko, R. N., & Feinberg, A. W. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01133 · Cited by 292
Self-citationSun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“As one of the components of body fluids, interstitial fluid occupies about 60–70% of body fluids, and its composition is mostly determined by the types of cells around it.”
Background
Metadata
- Authors
- Abdollahi, S., Markvicka, E. J., Majidi, C., & Feinberg, A. W.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2020-06-16
- Volume
- 9
- Issue
- 15
- Pages
- e1901735-e1901735
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3034794841
- Cited by
- 82
- References
- 10
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Printing Silicone Elastomer for Patient‐Specific Wearable Pulse Oximeter. https://app.cochat.ai/papers/10.1002/adhm.201901735
- The paper
- Abdollahi, S., Markvicka, E. J., Majidi, C., & Feinberg, A. W. (2020). 3D Printing Silicone Elastomer for Patient‐Specific Wearable Pulse Oximeter. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201901735
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.