The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Rational Design and Enhanced Biocompatibility of a Dry Adhesive Medical Skin Patch
Abstract
A new type of medical skin patch is developed that contains high-density, mushroom-like micropillars. Such dry-adhesive micropillars are highly biocompatible, have minimized side effects, and provide reasonable normal adhesion strength. To arrive at optimal conditions for the dry adhesive skin patch, the proper design of various structural and material parameters of micropillars is investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence for self-cleaning in gecko setae
Hansen, W. R., & Autumn, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408304102 · Cited by 601
Biologically inspired crack trapping for enhanced adhesion
Glassmaker, N. J., Jagota, A., Hui, C.-Y., Noderer, W. L., & Chaudhury, M. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703762104 · Cited by 258
Recent advances in the fabrication and adhesion testing of biomimetic dry adhesives
Sameoto, D., & Menon, C. (2010) · Smart Materials and Structures · doi:10.1088/0964-1726/19/10/103001 · Cited by 157
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Highly Skin‐Conformal Microhairy Sensor for Pulse Signal Amplification
Pang, C., Koo, J. H., Nguyen, A., Caves, J. M., Kim, M., Chortos, A., Kim, K., Wang, P. J., Tok, J. B. ‐., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201403807 · Cited by 734
Nanomaterial-Enabled Wearable Sensors for Healthcare
Yao, S., Swetha, P., & Zhu, Y. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700889 · Cited by 576
Recent advances in wet adhesives: Adhesion mechanism, design principle and applications
Cui, C., & Liu, W. (2021) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2021.101388 · Cited by 557
Metadata
- Authors
- Kwak, M. K., Jeong, H., & Suh, K. Y.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2011-07-28
- Volume
- 23
- Issue
- 34
- Pages
- 3949-3953
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2045040377
- Cited by
- 342
- References
- 3
- FWCI
- 23.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rational Design and Enhanced Biocompatibility of a Dry Adhesive Medical Skin Patch. https://app.cochat.ai/papers/10.1002/adma.201101694
- The paper
- Kwak, M. K., Jeong, H., & Suh, K. Y. (2011). Rational Design and Enhanced Biocompatibility of a Dry Adhesive Medical Skin Patch. Advanced Materials. https://doi.org/10.1002/adma.201101694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.