Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 373

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Highly Conformable Conducting Polymer Electrodes for In Vivo Recordings

Khodagholy, Dion, Doublet, Thomas, Gurfinkel, Moshe, Quilichini, Pascale, Ismailova, Esma, Leleux, Pierre, Herve, Thierry, Sanaur, Sébastien, Bernard, Christophe, Malliaras, George G.·2011·Advanced Materials

Abstract

A photolithographic process was used to integrate the conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) with parylene C, yielding highly conformable electrode arrays that were only four micrometers thick (shown here to conform to the midrib of a small leaf). The arrays were sufficiently self-supporting to allow in vivo evaluation in rats, yielding high-quality electrocorticography recordings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201102378

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 373

Metadata

Authors
Khodagholy, D., Doublet, T., Gurfinkel, M., Quilichini, P., Ismailova, E., Leleux, P., Herve, T., Sanaur, S., Bernard, C., & Malliaras, G. G.
Venue
Advanced Materials
Publisher
Wiley
Published
2011-08-09
Volume
23
Issue
36
Pages
H268-72
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2138185621
Cited by
373
References
29
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Conformable Conducting Polymer Electrodes for In Vivo Recordings. https://app.cochat.ai/papers/10.1002/adma.201102378
The paper
Khodagholy, D., Doublet, T., Gurfinkel, M., Quilichini, P., Ismailova, E., Leleux, P., Herve, T., Sanaur, S., Bernard, C., & Malliaras, G. G. (2011). Highly Conformable Conducting Polymer Electrodes for In Vivo Recordings. Advanced Materials. https://doi.org/10.1002/adma.201102378

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.