The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
X‐Space MPI: Magnetic Nanoparticles for Safe Medical Imaging
Open accessAbstract
One quarter of all iodinated contrast X‐ray clinical imaging studies are now performed on Chronic Kidney Disease (CKD) patients. Unfortunately, the iodine contrast agent used in X‐ray is often toxic to CKD patients’ weak kidneys, leading to significant morbidity and mortality. Hence, we are pioneering a new medical imaging method, called Magnetic Particle Imaging (MPI), to replace X‐ray and CT iodinated angiography, especially for CKD patients. MPI uses magnetic nanoparticle contrast agents that are much safer than iodine for CKD patients. MPI already offers superb contrast and extraordinary sensitivity. The iron oxide nanoparticle tracers required for MPI are also used in MRI, and some are already approved for human use, but the contrast agents are far more effective at illuminating blood vessels when used in the MPI modality. We have recently developed a systems theoretic framework for MPI called x‐space MPI, which has already dramatically improved the speed and robustness of MPI image reconstruction. X‐space MPI has allowed us to optimize the hardware for five MPI scanners. Moreover, x‐space MPI provides a powerful framework for optimizing the size and magnetic properties of the iron oxide nanoparticle tracers used in MPI. Currently MPI nanoparticles have diameters in the 10‐20 nanometer range, enabling millimeter‐scale resolution in small animals. X‐space MPI theory predicts that larger nanoparticles could enable up to 250 micrometer resolution imaging, which would represent a major breakthrough in safe imaging for CKD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Contrast-Induced Acute Kidney Injury
McCullough, P. A. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.12.035 · Cited by 822
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Gadolinium-based MR Contrast Agents and Nephrogenic Systemic Fibrosis
Kuo, P. H., Kanal, E., Abu-Alfa, A. K., & Cowper, S. E. (2007) · Radiology · doi:10.1148/radiol.2423061640 · Cited by 630
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
Biomimetic amplification of nanoparticle homing to tumors
Simberg, D., Duza, T., Park, J. H., Essler, M., Pilch, J., Zhang, L., Derfus, A. M., Yang, M., Hoffman, R. M., Bhatia, S., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610298104 · Cited by 471
FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease
Lu, M., Cohen, M. H., Rieves, D., & Pazdur, R. (2010) · American Journal of Hematology · doi:10.1002/ajh.21656 · Cited by 443
Goodwill, P. W., & Conolly, S. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2052284 · Cited by 395
Self-citationTwieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
Signal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Self-citationBarrett, T., Brechbiel, M., Bernardo, M., & Choyke, P. L. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20991 · Cited by 266
Contrast-induced nephrotoxicity: Clinical landscape
Katzberg, R. W., & Haller, C. (2006) · Kidney International · doi:10.1038/sj.ki.5000366 · Cited by 224
Optimization of nanoparticle core size for magnetic particle imaging
Ferguson, R. M., Minard, K. R., & Krishnan, K. M. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.083 · Cited by 222
Self-citationIx, J. H., Mercado, N., Shlipak, M. G., Lemos, P. A., Boersma, E., Lindeboom, W., O'Neill, W. W., Wijns, W., & Serruys, P. W. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.10.010 · Cited by 182
Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging
Ferguson, R. M., Minard, K. R., Khandhar, A. P., & Krishnan, K. M. (2011) · Medical Physics · doi:10.1118/1.3554646 · Cited by 162
Self-citationNew Classes of MRI Contrast Agents
Jacques, V., & Desreux, J. F. (2002) · Topics in current chemistry · doi:10.1007/3-540-45733-x_5 · Cited by 150
Narrowband Magnetic Particle Imaging
Goodwill, P. W., Scott, G., Stang, P. P., & Conolly, S. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013849 · Cited by 137
Self-citationKnopp, T., Biederer, S., Sattel, T. F., Erbe, M., & Buzug, T. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2113188 · Cited by 105
Ferrohydrodynamic relaxometry for magnetic particle imaging
Goodwill, P. W., Tamrazian, A., Croft, L. R., Lu, C.-N., Johnson, E., Pidaparthi, R., Ferguson, R. M., Khandhar, A. P., Krishnan, K. M., & Conolly, S. (2011) · Applied Physics Letters · doi:10.1063/1.3604009 · Cited by 91
Self-citationField-free line formation in a magnetic field
Knopp, T., Sattel, T. F., Biederer, S., & Buzug, T. M. (2009) · Journal of Physics A Mathematical and Theoretical · doi:10.1088/1751-8113/43/1/012002 · Cited by 48
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Self-citationRecent advances in magnetic nanoparticle-based multi-modal imaging
Shin, T.-H., Choi, Y., Kim, S., & Cheon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00345d · Cited by 602
Versatile Types of Organic/Inorganic Nanohybrids: From Strategic Design to Biomedical Applications
Zhao, N., Yan, L., Zhao, X., Chen, X., Li, A., Zheng, D., Zhou, X., Dai, X., & Xu, F.-J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00401 · Cited by 429
Unni, M., Uhl, A. M., Savliwala, S., Savitzky, B. H., Dhavalikar, R., Garraud, N., Arnold, D. P., Kourkoutis, L. F., Andrew, J. S., & Rinaldi, C. (2017) · ACS Nano · doi:10.1021/acsnano.7b00609 · Cited by 411
Metadata
- Authors
- Goodwill, P. W., Saritas, E. U., Croft, L. R., Kim, T. N., Krishnan, K. M., Schaffer, D. V., & Conolly, S. M.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2012-03-19
- Volume
- 24
- Issue
- 28
- Pages
- 3870-3877
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1994426390
- Cited by
- 301
- References
- 21
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.