CoChat

An All‐Elastomeric Transparent and Stretchable Temperature Sensor for Body‐Attachable Wearable Electronics

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

A transparent stretchable (TS) gated sensor array with high optical transparency, conformality, and high stretchability of up to 70% is demonstrated. The TS-gated sensor array has high responsivity to temperature changes in objects and human skin. This unprecedented TS-gated sensor array, as well as the integrated platform of the TS-gated sensor with a transparent and stretchable strain sensor, show great potential for application to wearable skin electronics for recognition of human activity.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.201504441

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 1

  1. 10.1021/acsnano.5b01613 · DOI · Paper page

Cited by

Items 701–800 of 870

Metadata

Authors
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N.
Affiliations
  • Sungkyunkwan University (KR)
  • Korea Institute of Science and Technology (KR)
Corresponding author
Lee, Nae‐Eung
Venue
Advanced Materials
Publisher
Wiley
Published
2015-11-26
Volume
28
Issue
3
Pages
502-509
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2174636528
Cited by
870
References
31
Citations by year
2026: 24 · 2025: 63 · 2024: 64 · 2023: 98 · 2022: 114 · 2021: 111 · 2020: 128 · 2019: 104 · 2018: 87 · 2017: 54 · 2016: 23
FWCI
27.16
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministry of Science, ICT & Future Planning (2010-0015035 and 2013R1A2A1A01015232)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
Keywords
temperature sensors, wearable electronics, strain sensors, human activity recognition, optical transparency, stretchability
MeSH terms
Elasticity, Equipment Design, Humans, Stress, Mechanical, Temperature, Elastomers, Electrical Equipment and Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.