Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Flexible Organic/Inorganic Hybrid Near‐Infrared Photoplethysmogram Sensor for Cardiovascular Monitoring

Xu, Huihua, Liu, Jing, Zhang, Jie, Zhou, Guodong, Luo, Ningqi, Zhao, Ni·2017·Advanced Materials

Abstract

Wearable photoplethysmogram (PPG) sensors offer convenient and informative measurements for evaluating daily physiological states of individuals. In this work, epidermal and flexible near‐infrared (NIR) PPG sensors integrating a low‐power, high‐sensitivity organic phototransistor (OPT) with a high‐efficiency inorganic light‐emitting diode are developed. By exploiting an organic bulk heterojunction active layer and a bilayer gate dielectric design, a low voltage (<3 V) operated OPT with NIR responsivity as high as 3.5 × 10 5 A W−1 and noise equivalent power of 1.2 × 10−15 W Hz−1/2 is achieved, greatly surpassing commercial available silicon‐based photodetectors. In addition, the ultrathin encapsulation structure renders the device highly flexible and allows transfer printing of the device directly onto human skin. It is demonstrated that the epidermal/flexible PPG sensors are capable of continuously monitoring heart rate variability and precisely tracking the changes of pulse pressure at different postures of human subjects with the aid of electrocardiogram monitoring, exhibiting more reliable performance than commercial PPG sensors while consuming less power. The study suggests that the hybrid PPG sensor design may provide a promising solution for low‐power, real‐time physiological monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201700975

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 298

Metadata

Authors
Xu, H., Liu, J., Zhang, J., Zhou, G., Luo, N., & Zhao, N.
Venue
Advanced Materials
Publisher
Wiley
Published
2017-06-14
Volume
29
Issue
31
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2625649160
Cited by
298
References
7
FWCI
8.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Organic/Inorganic Hybrid Near‐Infrared Photoplethysmogram Sensor for Cardiovascular Monitoring. https://app.cochat.ai/papers/10.1002/adma.201700975
The paper
Xu, H., Liu, J., Zhang, J., Zhou, G., Luo, N., & Zhao, N. (2017). Flexible Organic/Inorganic Hybrid Near‐Infrared Photoplethysmogram Sensor for Cardiovascular Monitoring. Advanced Materials. https://doi.org/10.1002/adma.201700975

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.