Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 509

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

A Magnetofluorescent Carbon Dot Assembly as an Acidic H2O2‐Driven Oxygenerator to Regulate Tumor Hypoxia for Simultaneous Bimodal Imaging and Enhanced Photodynamic Therapy

Jia, Qingyan, Ge, Jiechao, Liu, Weimin, Zheng, Xiuli, Chen, Shiqing, Wen, Yongmei, Zhang, Hongyan, Wang, Pengfei·2018·Advanced Materials

Abstract

Recent studies indicate that carbon dots (CDs) can efficiently generate singlet oxygen (1 O 2) for photodynamic therapy (PDT) of cancer. However, the hypoxic tumor microenvironment and rapid consumption of oxygen in the PDT process will severely limit therapeutic effects of CDs due to the oxygen‐dependent PDT. Thus, it is becoming particularly important to develop a novel CD as an in situ tumor oxygenerator for overcoming hypoxia and substantially enhancing the PDT efficacy. Herein, for the first time, magnetofluorescent Mn‐CDs are successfully prepared using manganese(II) phthalocyanine as a precursor. After cooperative self‐assembly with DSPE‐PEG, the obtained Mn‐CD assembly can be applied as a smart contrast agent for both near‐infrared fluorescence (FL) (maximum peak at 745 nm) and T1‐weighted magnetic resonance (MR) (relaxivity value of 6.97 mM−1 s−1) imaging. More interestingly, the Mn‐CD assembly can not only effectively produce 1 O 2 (quantum yield of 0.40) but also highly catalyze H 2 O 2 to generate oxygen. These collective properties of the Mn‐CD assembly enable it to be utilized as an acidic H 2 O 2‐driven oxygenerator to increase the oxygen concentration in hypoxic solid tumors for simultaneous bimodal FL/MR imaging and enhanced PDT. This work explores a new biomedical use of CDs and provides a versatile carbon nanomaterial candidate for multifunctional nanotheranostic applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201706090

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 509

Metadata

Authors
Jia, Q., Ge, J., Liu, W., Zheng, X., Chen, S., Wen, Y., Zhang, H., & Wang, P.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-02-13
Volume
30
Issue
13
Pages
e1706090-e1706090
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2789450843
Cited by
509
References
5
FWCI
26.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Magnetofluorescent Carbon Dot Assembly as an Acidic H2O2‐Driven Oxygenerator to Regulate Tumor Hypoxia for Simultaneous Bimodal Imaging and Enhanced Photodynamic Therapy. https://app.cochat.ai/papers/10.1002/adma.201706090
The paper
Jia, Q., Ge, J., Liu, W., Zheng, X., Chen, S., Wen, Y., Zhang, H., & Wang, P. (2018). A Magnetofluorescent Carbon Dot Assembly as an Acidic H2O2‐Driven Oxygenerator to Regulate Tumor Hypoxia for Simultaneous Bimodal Imaging and Enhanced Photodynamic Therapy. Advanced Materials. https://doi.org/10.1002/adma.201706090

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.