The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
A Compliant Ionic Adhesive Electrode with Ultralow Bioelectronic Impedance
Abstract
Simultaneous implementation of high signal‐to‐noise ratio (SNR) but low crosstalk is of great importance for weak surface electromyography (sEMG) signals when precisely driving a prosthesis to perform sophisticated activities. However, due to gaps with the curved skin during muscle contraction, many electrodes have poor compliance with skin and suffer from high bioelectrical impedance. This causes serious noise and error in the signals, especially the signals from low‐level muscle contractions. Here, the design of a compliant electrode based on an adhesive hydrogel, alginate–polyacrylamide (Alg‐PAAm) is reported, which eliminates those large gaps through the strong electrostatic interaction and abundant hydrogen bond with the skin. The obtained compliant electrode, having an ultralow bioelectrical impedance of ≈20 kΩ, can monitor even 2.1% maximal voluntary contraction (MVC) of muscle. Furthermore, benefiting from the high SNR of >5:1 at low‐level MVC, the crosstalk from irrelevant muscle is minimized through reducing the electrode size. Finally, a prosthesis is successfully demonstrated to precisely grasp a needle based on a 9 mm 2 Alg‐PAAm compliant electrode. The strategy to design such compliant electrodes provides the potential for improving the quality of dynamically weak sEMG signals to precisely control prosthesis in performing purposefully dexterous activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
The evolution of human skin and skin color
Jablonski, N. G. (2004) · Annual Review of Anthropology · doi:10.1146/annurev.anthro.33.070203.143955 · Cited by 367
Plasticizing Silk Protein for On‐Skin Stretchable Electrodes
Chen, G., Matsuhisa, N., Liu, Z., Qi, D., Cai, P., Jiang, Y., Wan, C., Cui, Y., Leow, W. R., Liu, Z., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800129 · Cited by 343
Self-citation
Cited by
Natural Biopolymer-Based Biocompatible Conductors for Stretchable Bioelectronics
Wang, C., Yokota, T., & Someya, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00897 · Cited by 412
Zhang, Z., Yang, J., Wang, H., Wang, C., Gu, Y., Xu, Y., Lee, S., Yokota, T., Haick, H., Someya, T., et al. (2024) · Science Advances · doi:10.1126/sciadv.adj5389 · Cited by 292
Mechanically Durable Memristor Arrays Based on a Discrete Structure Design
Wang, T., Cui, Z., Liu, Y., Lu, D., Wang, M., Wan, C., Leow, W. R., Wang, C., Pan, L., Cao, X., et al. (2022) · Advanced Materials · doi:10.1002/adma.202106212 · Cited by 42
Self-citationZhang, D., Chen, Z., Xiao, L., Zhu, B., Wu, R., Ou, C., Ma, Y., Xie, L., & Jiang, H. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00591-3 · Cited by 43
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 9
Metadata
- Authors
- Pan, L., Cai, P., Mei, L., Cheng, Y., Zeng, Y., Wang, M., Wang, T., Jiang, Y., Ji, B., Li, D., & Chen, X.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-08-07
- Volume
- 32
- Issue
- 38
- Pages
- e2003723-e2003723
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3047692618
- Cited by
- 167
- References
- 12
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Compliant Ionic Adhesive Electrode with Ultralow Bioelectronic Impedance. https://app.cochat.ai/papers/10.1002/adma.202003723
- The paper
- Pan, L., Cai, P., Mei, L., Cheng, Y., Zeng, Y., Wang, M., Wang, T., Jiang, Y., Ji, B., Li, D., & Chen, X. (2020). A Compliant Ionic Adhesive Electrode with Ultralow Bioelectronic Impedance. Advanced Materials. https://doi.org/10.1002/adma.202003723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.