CoChat

Stretchable and durable HD-sEMG electrodes for accurate recognition of swallowing activities on complex epidermal surfaces

Open access

Published version of a preprint

The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.

Abstract

Surface electromyography (sEMG) is widely used in monitoring human health. Nonetheless, it is challenging to capture high-fidelity sEMG recordings in regions with intricate curved surfaces such as the larynx, because regular sEMG electrodes have stiff structures. In this study, we developed a stretchable, high-density sEMG electrode array via layer-by-layer printing and lamination. The electrode offered a series of excellent human‒machine interface features, including conformal adhesion to the skin, high electron-to-ion conductivity (and thus lower contact impedance), prolonged environmental adaptability to resist water evaporation, and epidermal biocompatibility. This made the electrode more appropriate than commercial electrodes for long-term wearable, high-fidelity sEMG recording devices at complicated skin interfaces. Systematic in vivo studies were used to investigate its ability to classify swallowing activities, which was accomplished with high accuracy by decoding the sEMG signals from the chin via integration with an ear-mounted wearable system and machine learning algorithms. The results demonstrated the clinical feasibility of the system for noninvasive and comfortable recognition of swallowing motions for comfortable dysphagia rehabilitation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41378-023-00591-3

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Schematic illustration of the HD-sEMG electrode patch. a HD-sEMG electrode patch enables swallowing classification. b A layer-by-layer printing and lamination fabrication method
Fig. 1 Schematic illustration of the HD-sEMG electrode patch. a HD-sEMG electrode patch enables swallowing classification. b A layer-by-layer printing and lamination fabrication methodCC BY · PubMed Central
Fig. 2 Mechanical properties of the GW-PA gels. a optical photograph showing tight bonding between the GW-PA gel and human skin; b adhesion mechanisms of GW-PA gels; c FTIR-ATR spectra of the hydrogel with glycerin (GW-PA) or without glycerin (PA); d, e tensile strength, f, g interfacial toughness, and h, i adhesion strength of the GW-PA gels as a function of the glycerin content (0%, 25%, 50%, 75%). j, k Visual demonstration of strong adherence between the GW-PA gel and human skin with considerable stretching, compression, and twisting, which did not show any sign of detaching from the skin. Scale bar: 10 mm
Fig. 2 Mechanical properties of the GW-PA gels. a optical photograph showing tight bonding between the GW-PA gel and human skin; b adhesion mechanisms of GW-PA gels; c FTIR-ATR spectra of the hydrogel with glycerin (GW-PA) or without glycerin (PA); d, e tensile strength, f, g interfacial toughness, and h, i adhesion strength of the GW-PA gels as a function of the glycerin content (0%, 25%, 50%, 75%). j, k Visual demonstration of strong adherence between the GW-PA gel and human skin with considerable stretching, compression, and twisting, which did not show any sign of detaching from the skin. Scale bar: 10 mmCC BY · PubMed Central
Fig. 3 Electrical characterization with the GW-PA-Ag electrode. a Schematic representation of the sEMG signal traveling from the skin to the electrode with an equivalent circuit model; (b, c) Comparison of the contact impedances for three types of sEMG electrodes; (d) photograph of the GW-PA-Ag electrode used to measure sEMG signals from the submandibular of a participant practicing a swallowing muscle exercise; (e, f) results showing the amplitude and SNR of sEMG signals proportional to the submandibular force; (g, h) sEMG signal quality of the GW-PA-Ag electrode during cyclic deformation in comparison to the commercial electrode
Fig. 3 Electrical characterization with the GW-PA-Ag electrode. a Schematic representation of the sEMG signal traveling from the skin to the electrode with an equivalent circuit model; (b, c) Comparison of the contact impedances for three types of sEMG electrodes; (d) photograph of the GW-PA-Ag electrode used to measure sEMG signals from the submandibular of a participant practicing a swallowing muscle exercise; (e, f) results showing the amplitude and SNR of sEMG signals proportional to the submandibular force; (g, h) sEMG signal quality of the GW-PA-Ag electrode during cyclic deformation in comparison to the commercial electrodeCC BY · PubMed Central
Fig. 4 Long-term stability of the GW-PA-Ag electrode. a qualitative comparison of the mechanical strengths for the GW-PA and PA hydrogels after 7 days of drying; b time-dependent weight change of the GW-PA-Ag electrodes as a function of the glycerol content at a temperature of 25 °C and a humidity of 60%; c the PA-GW-Ag electrodes with 50% or 75% w/w glycerol maintained a SNR > 30 dB over 7 days
Fig. 4 Long-term stability of the GW-PA-Ag electrode. a qualitative comparison of the mechanical strengths for the GW-PA and PA hydrogels after 7 days of drying; b time-dependent weight change of the GW-PA-Ag electrodes as a function of the glycerol content at a temperature of 25 °C and a humidity of 60%; c the PA-GW-Ag electrodes with 50% or 75% w/w glycerol maintained a SNR > 30 dB over 7 daysCC BY · PubMed Central
Fig. 5 GW-PA-Ag electrode patch for swallowing detection. a schematic showing the patch placed on the swallowing muscles; b photographs of the patch connected with a 16-channel readout circuit. Scale bar: 5 mm. c Qualitative characterization of the patch under tension with an inflated balloon. Scale bar: 50 mm. d Photographs showing the crosstalk of the patch; e sEMG signal magnitudes for the FPL, FDS, and FCU muscles when the thumb moved, f and the crosstalk rate of the latter two on the FPL muscle as a function of electrode diameter. The g magnitude and h SNR of sEMG signals measured on the FPL as a function of electrode diameter
Fig. 5 GW-PA-Ag electrode patch for swallowing detection. a schematic showing the patch placed on the swallowing muscles; b photographs of the patch connected with a 16-channel readout circuit. Scale bar: 5 mm. c Qualitative characterization of the patch under tension with an inflated balloon. Scale bar: 50 mm. d Photographs showing the crosstalk of the patch; e sEMG signal magnitudes for the FPL, FDS, and FCU muscles when the thumb moved, f and the crosstalk rate of the latter two on the FPL muscle as a function of electrode diameter. The g magnitude and h SNR of sEMG signals measured on the FPL as a function of electrode diameterCC BY · PubMed Central
Fig. 6 Swallowing activity classification. Schematic illustration of (a) the swallowing recognition system with (b) the machine learning algorithm. c Raw sEMG signals for (d) 11 swallowing actions, each with 16-channel inputs. e Confusion matrix of the swallowing classification for the 11 swallowing actions
Fig. 6 Swallowing activity classification. Schematic illustration of (a) the swallowing recognition system with (b) the machine learning algorithm. c Raw sEMG signals for (d) 11 swallowing actions, each with 16-channel inputs. e Confusion matrix of the swallowing classification for the 11 swallowing actionsCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

See all 43

Metadata

Authors
Zhang, D., Chen, Z., Xiao, L., Zhu, B., Wu, R., Ou, C., Ma, Y., Xie, L., & Jiang, H.
Affiliations
South China University of Technology (CN)
Corresponding author
  • Xie, Longhan
  • Jiang, Hongjie
Venue
Microsystems & Nanoengineering
Published
2023-09-18
Volume
9
Issue
1
Pages
115-115
ISSN
2055-7434 (ISSN-L)
OpenAlex
W4386835103
Cited by
43
References
46
Citations by year
2026: 13 · 2025: 20 · 2024: 8 · 2023: 2
FWCI
3.39
Type
journal article
Language
en
Open access
Licence
Locations
  • Microsystems & Nanoengineering (publishedVersion, cc-by)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Natural Science Foundation of China (No. 52075177, 52075177, 42177440, Grant No. 52075177, 51903079)
  • National Key Research and Development Program of China (No. 2021YFB3301400, 52075177, 2021YFB3301400)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
high-density electrode arrays, swallowing rehabilitation, laryngeal electromyography, layer-by-layer printing, lamination, contact impedance, wearable sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stretchable and durable HD-sEMG electrodes for accurate recognition of swallowing activities on complex epidermal surfaces. https://app.cochat.ai/papers/10.1038/s41378-023-00591-3
The paper
Zhang, D., Chen, Z., Xiao, L., Zhu, B., Wu, R., Ou, C., Ma, Y., Xie, L., & Jiang, H. (2023). Stretchable and durable HD-sEMG electrodes for accurate recognition of swallowing activities on complex epidermal surfaces. Microsystems & Nanoengineering. https://doi.org/10.1038/s41378-023-00591-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.