Modular Synthesis of Semiconducting Graft Copolymers to Achieve “Clickable” Fluorescent Nanoparticles with Long Circulation and Specific Cancer Targeting
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Semiconducting polymer nanoparticles (SPNs) are explored for applications in cancer theranostics because of their high absorption coefficients, photostability, and biocompatibility. However, SPNs are susceptible to aggregation and protein fouling in physiological conditions, which can be detrimental for in vivo applications. Here, a method for achieving colloidally stable and low‐fouling SPNs is described by grafting poly(ethylene glycol) (PEG) onto the backbone of the fluorescent semiconducting polymer, poly(9,9′‐dioctylfluorene‐5‐fluoro‐2,1,3‐benzothiadiazole), in a simple one‐step substitution reaction, postpolymerization. Further, by utilizing azide‐functionalized PEG, anti‐human epidermal growth factor receptor 2 (HER2) antibodies, antibody fragments, or affibodies are site‐specifically “clicked” onto the SPN surface, which allows the functionalized SPNs to specifically target HER2‐positive cancer cells. In vivo, the PEGylated SPNs are found to have excellent circulation efficiencies in zebrafish embryos for up to seven days postinjection. SPNs functionalized with affibodies are then shown to be able to target HER2 expressing cancer cells in a zebrafish xenograft model. The covalent PEGylated SPN system described herein shows great potential for cancer theranostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, SPNs have been shown to have a superior photostability when compared to typical fluorescent dyes22,23.”
From Bright and stable anti-counterfeiting devices with independent stochastic processes covering multiple length scales (2025) · cites this paper as [23]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicolor Fluorescent Semiconducting Polymer Dots with Narrow Emissions and High Brightness
Rong, Y., Wu, C., Yu, J., Zhang, X., Ye, F., Zeigler, M., Gallina, M. E., Wu, I.-C., Zhang, Y., Chan, Y.-H., et al. (2013) · ACS Nano · doi:10.1021/nn304376z · Cited by 215
Cheng, K., Chen, H., Jenkins, C. H., Zhang, G., Zhao, W., Zhang, Z., Han, F., Fung, J., Yang, M., Jiang, Y., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05966 · Cited by 156
Yang, Z., Zheng, S., Harrison, W. J., Harder, J., Wen, X., Gelovani, J. G., Qiao, A., & Li, C. (2007) · Biomacromolecules · doi:10.1021/bm7005399 · Cited by 130
Research works printed but not linked: 58
- 10.1016/j.biomaterials.2017.11.025 · DOI · Paper page
- 10.1021/acs.accounts.9b00569 · DOI · Paper page
- 10.1039/D0MH00012D · DOI
- 10.1002/anie.201814730 · DOI · Paper page
- 10.1021/jacs.8b13507 · DOI · Paper page
- 10.1002/ange.201808074 · DOI
- 10.7150/thno.34390 · DOI · Paper page
- 10.1039/D0SC01721C · DOI
- 10.1002/adfm.201605397 · DOI · Paper page
- 10.1002/adma.201801331 · DOI · Paper page
- 10.1080/17425247.2021.1874916 · DOI
- 10.1002/adma.202110305 · DOI
- 10.1021/acsanm.9b02292 · DOI
- 10.1021/ja107196s · DOI · Paper page
- 10.1016/0300-483X(95)03123-W · DOI · Paper page
- 10.1080/14686996.2017.1370361 · DOI
- 10.1039/C6SC02403C · DOI · Paper page
- 10.1016/j.jconrel.2020.01.035 · DOI · Paper page
- 10.1158/1078-0432.CCR-03-0041 · DOI
- 10.2147/IJN.S153795 · DOI
- 10.1042/BJ20101860 · DOI · Paper page
- 10.1016/j.jbiotec.2009.01.014 · DOI
- 10.1016/j.ddtec.2018.10.005 · DOI · Paper page
- 10.1007/s00259-007-0658-0 · DOI · Paper page
- 10.1038/s41419-020-03077-6 · DOI
- 10.1016/j.biomaterials.2010.11.053 · DOI
- 10.1002/smll.201002291 · DOI · Paper page
- Narsireddy A., 2015, Int. J. Nanomed., 10, 6865
- 10.1002/smll.201602807 · DOI · Paper page
- 10.1039/c3py00605k · DOI
- 10.1002/smll.201906719 · DOI
- 10.1016/j.ebiom.2020.102902 · DOI
- 10.1021/acsapm.2c01153 · DOI
- 10.1021/acs.analchem.9b03010 · DOI
- 10.1021/acsami.5b04987 · DOI
- 10.1039/C6RA18678E · DOI
- 10.1038/s41598-022-15244-0 · DOI
- 10.1002/mabi.202000087 · DOI
- 10.1038/s41467-018-05381-4 · DOI
- 10.1007/s10118-021-2537-8 · DOI
- 10.1039/D2MH00519K · DOI
- 10.1002/ppsc.201400123 · DOI · Paper page
- 10.1039/C5TB01827G · DOI
- 10.1002/adhm.201300534 · DOI
- 10.1002/adma.201502285 · DOI · Paper page
- 10.1002/smll.202004723 · DOI · Paper page
- 10.1039/C8SC00206A · DOI · Paper page
- 10.1002/ange.201303420 · DOI
- 10.1002/smll.201907574 · DOI · Paper page
- 10.1021/acscentsci.1c01368 · DOI
- 10.1002/smll.202201993 · DOI
- 10.1039/D0OB00106F · DOI
- 10.1039/D2OB00310D · doi:10.1039/d2ob00310d
- 10.1021/acsnano.7b06995 · DOI · Paper page
- 10.1002/adma.201906274 · DOI
- 10.1021/nn506750r · DOI
- 10.1093/bioinformatics/btu328 · DOI
- Kapusta P., 2010, Absolute Diffusion Coefficients: Compilation of Reference Data for FCS Calibration
Cited by
Zhang, J., Creamer, A., Xie, K., Tang, J., Salter, L., Wojciechowski, J. P., & Stevens, M. M. (2025) · Nature Communications · doi:10.1038/s41467-024-55646-4 · Cited by 33
Self-citation
Metadata
- Authors
- Creamer, A., Fiego, A. L., Agliano, A., Prados‐Martin, L., Høgset, H., Najer, A., Richards, D. A., Wojciechowski, J. P., Foote, J. E. J., Kim, N., Monahan, A., Tang, J., Shamsabadi, A., Rochet, L. N. C., Thanasi, I. A., de la Ballina, L. R., Rapley, C. L., Turnock, S., Love, E. A., Bugeon, L., Dallman, M. J., Heeney, M., Kramer‐Marek, G., Chudasama, V., Fenaroli, F., & Stevens, M. M.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2023-04-02
- Volume
- 36
- Issue
- 20
- ISSN
- 0935-9648
- 1521-4095
- Cited by
- 27
- References
- 3
- Language
- en
- Funders
- Cancer Research UK (100063, 27886, 29385)
- Leverhulme Trust
- Engineering and Physical Sciences Research Council (EP/S023518/1, EP/K020641/1, EP/T517793/1)
- Wellcome Trust (209121_Z_17_Z)
- UK Regenerative Medicine Platform (MR/R015651/1)
- Rosetrees Trust
- European Commission (859458)
- LifeArc
- Institute of Cancer Research
- Royal Society
- Wolfson Foundation
- Kreftforeningen (711091)
- H2020 Excellent Science (859458)
- University College London
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.