Pulse Oximetry Using Organic Optoelectronics under Ambient Light
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Light absorption in oxygenated and deoxygenated blood varies appreciably over the visible and near‐infrared spectrum. Pulse oximeters use two distinct wavelengths of light to measure oxygen saturation SpO 2 of blood. Currently, light‐emitting diodes (LEDs) are used in oximeters, which need additional components to drive them and negatively impact the overall size of the sensor. In this work, an ambient light oximeter (ALO) is demonstrated, which can measure photoplethysmography signals and SpO 2 using various kinds of ambient light, avoiding the use of LEDs. Spectral filters are combined with organic photodiodes to create the ALO with sensitivity peaks at green (525 nm), red (610 nm), and near‐infrared (740 nm) wavelengths. Finally, the wearable ALO is used to measure photoplethysmography signals and SpO 2 on the index finger in different indoor and outdoor lighting conditions and the measurements are validated with commercial pulse oximeters under normal and ischemic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Multifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
Self-citationArtifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Wearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205
Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring
Khan, Y., Han, D., Ting, J., Ahmed, M., Nagisetty, R., & Arias, A. C. (2019) · IEEE Access · doi:10.1109/access.2019.2939798 · Cited by 111
Self-citation
Cited by
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
The Bulk Heterojunction in Organic Photovoltaic, Photodetector, and Photocatalytic Applications
Wadsworth, A., Hamid, Z., Kosco, J., Gasparini, N., & McCulloch, I. (2020) · Advanced Materials · doi:10.1002/adma.202001763 · Cited by 332
Self-citationRecent Progress on Broadband Organic Photodetectors and their Applications
Zhao, Z., Xu, C., Niu, L., Zhang, X., & Zhang, F. (2020) · Laser & Photonics Reviews · doi:10.1002/lpor.202000262 · Cited by 290
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“The system can detect the concentration of lactate in the blood during exercise to predict the lactate threshold.”
Background
Metadata
- Authors
- Han, D., Khan, Y., Ting, J., Zhu, J., Combe, C., Wadsworth, A., McCulloch, I., & Arias, A. C.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2020-03-06
- Volume
- 5
- Issue
- 5
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W3009191727
- Cited by
- 80
- References
- 9
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.