The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Vitrification and Rewarming of Magnetic Nanoparticle‐Loaded Rat Hearts
Abstract
To extend the preservation of donor hearts beyond the current 4–6 h, this paper explores heart cryopreservation by vitrification—cryogenic storage in a glass‐like state. While organ vitrification is made possible by using cryoprotective agents (CPA) that inhibit ice during cooling, failure occurs during convective rewarming due to slow and non‐uniform rewarming which causes ice crystallization and/or cracking. Here an alternative, “nanowarming”, which uses silica‐coated iron oxide nanoparticles (sIONPs) perfusion loaded through the vasculature is explored, that allows a radiofrequency coil to rewarm the organ quickly and uniformly to avoid convective failures. Nanowarming has been applied to cells and tissues, and a proof of principle study suggests it is possible in the heart, but proper physical and biological characterization especially in organs is still lacking. Here, using a rat heart model, controlled machine perfusion loading and unloading of CPA and sIONPs, cooling to a vitrified state, and fast and uniform nanowarming without crystallization or cracking is demonstrated. Further, nanowarmed hearts maintain histologic appearance and endothelial integrity superior to convective rewarming and indistinguishable from CPA load/unload control hearts while showing some promising organ‐level (electrical) functional activity. This work demonstrates physically successful heart vitrification and nanowarming and that biological outcomes can be expected to improve by reducing or eliminating CPA toxicity during loading and unloading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CPA damage, not physical injury from vitrification and nanowarming, was the limiting step for biologic and functional recovery.
“We found that CPA damage, not physical injury from vitrification and nanowarming, was the limiting step for biologic and functional recovery.”
From Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model (2023) · cites this paper as [17]
In past work, nanowarming could rewarm vitrified organs including kidneys from animal models with physical success, but only partial biological recovery and no transplant data.
“In the past, we and others have shown that nanowarming can rewarm vitrified organs (including kidneys) from animal models with physical success, but only partial biological recovery and no transplant data17–20.”
From Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model (2023) · cites this paper as [17]
Nanowarming of volumes up to 80 mL CPA and 30 mL biological at rates up to 50-100 °C/min has been published.
“So far, we and others have published on nanowarming of volumes up to 80 mL CPA mL and 30 mL biological nanowarming at rates up to 50–100 °C/min14–19 (see Table S1).”
From Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation (2025) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guardia, P., Di Corato, R., Lartigue, L., Wilhelm, C., Espinosa, A., Garcia-Hernandez, M., Gazeau, F., Manna, L., & Pellegrino, T. (2012) · ACS Nano · doi:10.1021/nn2048137 · Cited by 752
Flagged first, then by citations
Research works printed but not linked: 68
- 10.1111/ajt.15676 · DOI
- 10.1093/ejcts/ezu117 · DOI
- 10.1016/S0003-4975(99)01028-0 · DOI
- Nutt M., 1992, Circulation, 86, II333
- 10.1016/0003-4975(95)00761-X · DOI
- 10.1016/0891-5849(92)90101-L · DOI
- 10.1016/j.hlc.2013.07.011 · DOI
- 10.1111/tri.12361 · DOI
- 10.1016/S0022-5223(98)00452-8 · DOI
- 10.1016/j.hlc.2015.01.005 · DOI
- 10.1016/j.healun.2019.01.088 · DOI
- IuS A., 2008, Usp. Fiziol. Nauk, 39, 66
- 10.1159/000499453 · DOI
- 10.1016/0011-2240(84)90079-8 · DOI · Paper page
- 10.1089/cpt.2006.9994 · DOI
- 10.1126/scitranslmed.aah4586 · DOI · Paper page
- 10.1115/1.4047420 · DOI
- 10.1089/cpt.2007.9994 · DOI · Paper page
- 10.1016/0011-2240(90)90038-6 · DOI · Paper page
- 10.1016/0011-2240(72)90050-8 · DOI
- 10.1016/j.jtcvs.2007.08.056 · DOI
- 10.1039/C9NR01182J · DOI · Paper page
- 10.1002/advs.201901624 · DOI · Paper page
- 10.1126/sciadv.abe3005 · DOI · Paper page
- 10.1016/j.actbio.2016.01.026 · DOI
- 10.1002/admt.201800289 · DOI
- 10.1142/S2339547814500204 · DOI · Paper page
- 10.1021/acsnano.7b01762 · DOI
- 10.1021/acs.accounts.0c00355 · DOI
- 10.1016/j.lfs.2019.01.056 · DOI
- 10.1016/j.biomaterials.2017.11.012 · DOI
- 10.1002/adma.201904598 · DOI
- 10.1002/adfm.202002541 · DOI
- 10.1038/srep08579 · DOI
- 10.1126/sciadv.aaz0952 · DOI
- 10.1016/S0011-2240(03)00045-2 · DOI
- 10.1007/BF01812150 · DOI
- 10.1016/j.vascn.2006.05.006 · DOI
- 10.1016/S0003-4975(10)61782-1 · DOI
- 10.1001/archsurg.1964.01320040061009 · DOI
- Bergmann S. R., 1979, Am. J. Physiol., 236, H644
- 10.1016/0011-2240(86)90006-4 · DOI
- 10.1002/mrm.26394 · DOI
- 10.1002/mrm.26800 · DOI
- 10.1002/mrm.28123 · DOI
- 10.1006/cryo.1996.0044 · DOI
- Han Z., 2020, CryoLetters, 41, 185
- 10.1016/j.cryogenics.2014.09.005 · DOI
- 10.1016/j.cryobiol.2009.05.007 · DOI
- 10.1115/1.4032053 · DOI
- 10.1007/s10815-015-0513-3 · DOI
- 10.4161/org.5.3.9974 · DOI · Paper page
- 10.1016/j.cryobiol.2017.02.001 · DOI
- 10.1002/adhm.202000796 · DOI
- 10.1093/gigascience/gix027 · DOI
- Bernemann I., 2010, CryoLetters, 31, 493
- 10.1007/s10439-006-9176-7 · DOI
- 10.1016/j.jmr.2014.11.014 · DOI
- 10.1002/(SICI)1522-2594(199907)42:1<206::AID-MRM28>3.0.CO;2-Q · DOI
- 10.1161/01.HYP.4.6.864 · DOI
- 10.1115/1.4037406 · DOI
- 10.1016/j.cryobiol.2019.09.007 · DOI
- 10.3389/fphys.2018.00943 · DOI
- 10.14814/phy2.12786 · DOI
- Ehrlich L. E., 2020, PLoS One, 15, e0238941, 10.1371/journal.pone.0238941 · DOI
- 10.1039/tf9454100049 · DOI
- 10.1063/1.555636 · DOI
- 10.1016/0032-3861(65)90042-X · DOI
Cited by
Sorted by citations
Han, Z., Rao, J. S., Gangwar, L., Namsrai, B.-E., Pasek-Allen, J. L., Etheridge, M. L., Wolf, S. M., Pruett, T. L., Bischof, J. C., & Finger, E. B. (2023) · Nature Communications · doi:10.1038/s41467-023-38824-8 · Cited by 173
Self-citationPhysical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation
Gangwar, L., Han, Z., Scheithauer, C., Namsrai, B.-E., Kantesaria, S., Goldstein, R., Etheridge, M. L., Finger, E. B., & Bischof, J. C. (2025) · Nature Communications · doi:10.1038/s41467-025-63483-2 · Cited by 26
Self-citation
Metadata
- Authors
- Gao, Z., Namsrai, B., Han, Z., Joshi, P., Rao, J. S., Ravikumar, V., Sharma, A., Ring, H. L., Idiyatullin, D., Magnuson, E. C., Iaizzo, P. A., Tolkacheva, E. G., Garwood, M., Rabin, Y., Etheridge, M., Finger, E. B., & Bischof, J. C.
- Affiliations
- Department of Mechanical Engineering University of Minnesota 111 Church St. SE. Minneapolis MN 55455 USA
- Department of Surgery University of Minnesota 420 Delaware Street SE Minneapolis MN 55455 USA
- Department of Mechanical Engineering Carnegie Mellon University 5000 Forbes Avenue Pittsburgh PA 15213 USA
- Department of Biomedical Engineering University of Minnesota 312 Church St. SE Minneapolis MN 55455 USA
- Center for Magnetic Resonance Research Department of Radiology University of Minnesota 2021 6th Street S.E. Minneapolis Minneapolis MN 55455 USA
- ORCID
- Bischof, John C.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2021-10
- Volume
- 7
- Issue
- 3
- ISSN
- 2365-709X
- PMC
- PMC9164386
- Cited by
- 78
- References
- 1
- Language
- en
- Funders
- National Institutes of Health (R01 HL135046, R01 DK117425)
- National Science Foundation (1941543)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review