Development and characterization of pH‐responsive polyethylene glycol‐co‐poly(methacrylic acid) polymeric network system for colon target delivery of oxaliplatin: Its acute oral toxicity study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
An oral route of administration is a most acceptable route for a patient, so we designed chemically cross‐linked polyethylene glycol‐co‐poly(methacrylic acid) oral hydrogels (PEGMA 4000) by free radical polymerization method for pH‐responsive colon target delivery of oxaliplatin (OXP). Polyethylene glycol (PEG 4000) was cross‐linked chemically with methacrylic acid (MAA) in distilled water. Ammonium peroxodisulfate (APS) and N, N‐methylene bisacrylamide (MBA) were used as initiator and cross‐linker respectively. OXP was loaded in prepared hydrogels. FTIR, DSC, TGA, SEM, and XRD were conducted for characterization of developed hydrogels which endorsed the formation of new polymeric network. The pH‐sensitive behavior of hydrogels was observed by swelling dynamics and equilibrium swelling ratio at low (1.2) and higher pH (7.4). Toxicity study was also conducted on rabbits to evaluate toxicity and biocompatibility of developed carrier system to biological system. Hydrogels with higher PEG 4000 concentration showed maximum swelling and higher drug loading at 7.4 pH. Toxicity study confirmed the developed hydrogels as non‐toxic and biocompatible for biological system. Resultantly, these hydrogels can become an excellent candidates for colon targeting of OXP to treat colorectal cancer with no toxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogel: Preparation, characterization, and applications: A review
Ahmed, E. M. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2013.07.006 · Cited by 5,800
Samanta, H. S., & Ray, S. K. (2014) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2013.09.004 · Cited by 293
Murthy, P. S. K., Mohan, Y. M., Sreeramulu, J., & Raju, K. M. (2006) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2006.04.010 · Cited by 156
Singh, B., Sharma, N., & Chauhan, N. (2007) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2007.01.020 · Cited by 95
Cited by
Review of Stimuli-Responsive Polymers in Drug Delivery and Textile Application
CHATTERJEE, S., & Chi-leung HUI, P. (2019) · Molecules · doi:10.3390/molecules24142547 · Cited by 201
“The pH-responsive hydrogel made of the co-polymeric network of PEG and poly(methacrylic acid) was used for oral delivery of model drug oxaliplatin and it was used for colon targeting of the drug [116].”
MethodMalik, N. S., Ahmad, M., Alqahtani, M. S., Mahmood, A., Barkat, K., Khan, M. T., Tulain, U. R., & Rashid, A. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1921074 · Cited by 57
Self-citationNasir, N., Ahmad, M., Minhas, M. U., Barkat, K., & Khalid, M. F. (2019) · Journal of Polymer Research · doi:10.1007/s10965-019-1872-8 · Cited by 52
Self-citationRetractedSuhail, M., Chiu, I.-H., Hung, M.-C., Vu, Q. L., Lin, I.-L., & Wu, P.-C. (2022) · Gels · doi:10.3390/gels8070406 · Cited by 26
“Hence, we can conclude that thermal stability of the developed hydrogel was greater than Cs and Sps [58,59].”
BackgroundSuhail, M., Liu, J.-Y., Hsieh, W.-C., Lin, Y.-W., Usman Minhas, M., & Wu, P.-C. (2022) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2021.103590 · Cited by 20
Metadata
- Authors
- Barkat, K., Ahmad, M., Usman Minhas, M., Khalid, I., & Nasir, B.
- Venue
- Advances in Polymer Technology
- Publisher
- Wiley
- Published
- 2017-05-25
- Volume
- 37
- Issue
- 6
- Pages
- 1806-1822
- ISSN
- 0730-6679 (ISSN-L)
- 1098-2329
- OpenAlex
- W2617070659
- Cited by
- 72
- References
- 4
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.