The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Simple 3D Printed Scaffold‐Removal Method for the Fabrication of Intricate Microfluidic Devices
Open accessAbstract
An easy and cheap fabrication method for intricate polydimethylsiloxane microfluidic devices is presented. The acrylonitrile butadiene styrene scaffold-removal method uses cheap, off-the-shelf materials and equipment for the fabrication of intricate microfluidic devices. The versatility of the method is proven by the fabrication of 3D multilayer, ship-in-a-bottle, selective heating, sensing, and NMR microfluidic devices. The methodology is coined ESCARGOT: Embedded SCAffold RemovinG Open Technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Fabricated: The New World of 3D Printing
Lipson, H., & Kurman, M. (2013) · Cited by 1,032
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Microfluidic scaffolds for tissue engineering
Choi, N. W., Cabodi, M., Held, B., Gleghorn, J. P., Bonassar, L. J., & Stroock, A. D. (2007) · Nature Materials · doi:10.1038/nmat2022 · Cited by 622
Cost-Effective Three-Dimensional Printing of Visibly Transparent Microchips within Minutes
Shallan, A. I., Smejkal, P., Corban, M., Guijt, R. M., & Breadmore, M. C. (2014) · Analytical Chemistry · doi:10.1021/ac4041857 · Cited by 501
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Configurable 3D-Printed millifluidic and microfluidic ‘lab on a chip’ reactionware devices
Kitson, P. J., Rosnes, M. H., Sans, V., Dragone, V., & Cronin, L. (2012) · Lab on a Chip · doi:10.1039/c2lc40761b · Cited by 484
3D printed microfluidic devices with integrated versatile and reusable electrodes
Erkal, J. L., Selimovic, A., Gross, B. C., Lockwood, S. Y., Walton, E. L., McNamara, S., Martin, R. S., & Spence, D. M. (2014) · Lab Chip · doi:10.1039/c4lc00171k · Cited by 287
Sugioka, K., Xu, J., Wu, D., Hanada, Y., Wang, Z., Cheng, Y., & Midorikawa, K. (2014) · Lab Chip · doi:10.1039/c4lc00548a · Cited by 259
Kamei, K.-I., Mashimo, Y., Koyama, Y., Fockenberg, C., Nakashima, M., Nakajima, M., Li, J., & Chen, Y. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9928-y · Cited by 196
Print your own membrane: direct rapid prototyping of polydimethylsiloxane
Femmer, T., Kuehne, A. J. C., & Wessling, M. (2014) · Lab on a Chip · doi:10.1039/c4lc00320a · Cited by 161
Verma, M. K. S., Majumder, A., & Ghatak, A. K. (2006) · Langmuir · doi:10.1021/la062516n · Cited by 143
New materials for microfluidics in biology
Ren, K., Chen, Y., & Wu, H. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.004 · Cited by 142
Small-Volume Nuclear Magnetic Resonance Spectroscopy
Fratila, R. M., & Velders, A. H. (2011) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061010-114024 · Cited by 109
Self-citationMonolithic multilayer microfluidics via sacrificial molding of 3D-printed isomalt
Gelber, M. K., & Bhargava, R. (2015) · Lab on a Chip · doi:10.1039/c4lc01392a · Cited by 91
Applications of Microfluidics in Stem Cell Biology
Zhang, Q., & Austin, R. H. (2012) · BioNanoScience · doi:10.1007/s12668-012-0051-8 · Cited by 80
PDMS microchannel fabrication technique based on microwire-molding
Jia, Y., Jiang, J., Ma, X., Li, Y., Huang, H., Cai, K., Cai, S., & Wu, Y. (2008) · 中国科学通报:英文版 · doi:10.1007/s11434-008-0528-6 · Cited by 68
Fratila, R., Gomez, M., Sykora, S., & Velders, A. (2014) · Nature Communications · doi:10.1038/ncomms4025 · Cited by 59
Self-citationChemistry: Breaking the billion-hertz barrier
Bhattacharya, A. (2010) · Nature · doi:10.1038/463605a · Cited by 49
Cited by
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
Nielsen, A. V., Beauchamp, M. J., Nordin, G. P., & Woolley, A. T. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091619-102649 · Cited by 339
3D printing for chemical, pharmaceutical and biological applications
Capel, A. J., Rimington, R. P., Lewis, M. P., & Christie, S. D. R. (2018) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0058-y · Cited by 312
3D printing: an emerging tool for novel microfluidics and lab-on-a-chip applications
Yazdi, A. A., Popma, A., Wong, W., Nguyen, T., Pan, Y., & Xu, J. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1715-4 · Cited by 307
Recapitulating the vasculature using ORGAN-ON-CHIP technology
Pollet, A. M. A. O., & den Toonder, J. M. J. (2020) · Bioengineering · doi:10.3390/bioengineering7010017 · Cited by 73
Metadata
- Authors
- Saggiomo, V., & Velders, A. H.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2015-07-16
- Volume
- 2
- Issue
- 9
- Pages
- 1500125-1500125
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W1962135887
- Cited by
- 266
- References
- 29
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.