Abstract
Implantable medical electronic devices are usually powered by batteries or capacitors, which have to be removed from the body after completing their function due to their non‐biodegradable property. Here, a fully bioabsorbable capacitor (BC) is developed for life‐time implantation. The BC has a symmetrical layer‐by‐layer structure, including polylactic acid (PLA) supporting substrate, PLA nanopillar arrays, self‐assembled zinc oxide nanoporous layer, and polyvinyl alcohol/phosphate buffer solution (PVA/PBS) hydrogel. The as‐fabricated BC can not only work normally in air but also in a liquid environment, including PBS and the animal body. Long‐term normal work time is achieved to 30 days in PBS and 50 days in Sprague–Dawley (SD) rats. The work time of BC in the liquid environment is tunable from days to weeks by adopting different encapsulations along BC edges. Capacitance retention of 70% is achieved after 3000 cycles. Three BCs in series can light up 15 green light‐emitting diodes (LEDs) in vivo. Additionally, after completing its mission, the BC can be fully degraded in vivo and reabsorbed by a SD rat. Considering its performance, the developed BC has a great potential as a fully bioabsorbable power source for transient electronics and implantable medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648
Self-citationBiodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Self-citationFully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
Self-citationDeroiné, M., Le Duigou, A., Corre, Y.-M., Le Gac, P.-Y., Davies, P., César, G., & Bruzaud, S. (2014) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2014.01.020 · Cited by 279
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
Cited by
The Evolution of Flexible Electronics: From Nature, Beyond Nature, and To Nature
Wang, P., Hu, M., Wang, H., Chen, Z., Feng, Y., Wang, J., Ling, W., & Huang, Y. (2020) · Advanced Science · doi:10.1002/advs.202001116 · Cited by 397
Biodegradable Materials and Green Processing for Green Electronics
Li, W., Liu, Q., Zhang, Y., Li, C., He, Z., Choy, W. C. H., Low, P. J., Sonar, P., & Kyaw, A. K. K. (2020) · Advanced Materials · doi:10.1002/adma.202001591 · Cited by 388
Yang, Q., Huang, Z., Li, X., Liu, Z., Li, H., Liang, G., Wang, D., Huang, Q., Zhang, S., Chen, S., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b03650 · Cited by 309
Self-citationSheng, H., Zhou, J., Li, B., He, Y., Zhang, X., Liang, J., Zhou, J., Su, Q., Xie, E., Lan, W., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe3097 · Cited by 180
A Bioresorbable Dynamic Pressure Sensor for Cardiovascular Postoperative Care
Ouyang, H., Li, Z., Gu, M., Hu, Y., Xu, L., Jiang, D., Cheng, S., Zou, Y., Deng, Y., Shi, B., et al. (2021) · Advanced Materials · doi:10.1002/adma.202102302 · Cited by 160
Self-citation
Metadata
- Authors
- Li, H., Zhao, C., Wang, X., Meng, J., Zou, Y., Noreen, S., Zhao, L., Liu, Z., Ouyang, H., Tan, P., Yu, M., Fan, Y., Wang, Z. L., & Li, Z.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2019-01-22
- Volume
- 6
- Issue
- 6
- Pages
- 1801625-1801625
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2912036416
- Cited by
- 151
- References
- 8
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.