Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Engineered Microstructure Derived Hierarchical Deformation of Flexible Pressure Sensor Induces a Supersensitive Piezoresistive Property in Broad Pressure Range

Open access
Li, Gang, Chen, Duo, Li, Chenglong, Liu, Wenxia, Liu, Hong · 2020 · Advanced Science

Abstract

Fabricating flexible pressure sensors with high sensitivity in a broad pressure range is still a challenge. Herein, a flexible pressure sensor with engineered microstructures on polydimethylsiloxane (PDMS) film is designed. The high performance of the sensor derives from its unique pyramid‐wall‐grid microstructure (PWGM). A square array of dome‐topped pyramids and crossed strengthening walls on the film forms a multiheight hierarchical microstructure. Two pieces of PWGM flexible PDMS film, stacked face‐to‐face, form a piezoresistive sensor endowed with ultrahigh sensitivity across a very broad pressure range. The sensitivity of the device is as high as 383 665.9 and 269 662.9 kPa−1 in the pressure ranges 0–1.6 and 1.6–6 kPa, respectively. In the higher pressure range of 6.1–11 kPa, the sensitivity is 48 689.1 kPa−1, and even in the very high pressure range of 11–56 kPa, it stays at 1266.8 kPa−1. The pressure sensor possesses excellent bending and torsional strain detection properties, is mechanically durable, and has potential applications in wearable biosensing for healthcare. In addition, 2 × 2 and 4 × 4 sensor arrays are prepared and characterized, suggesting the possibility of manufacturing a flexible tactile sensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.202000154

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 199

Metadata

Authors
Li, G., Chen, D., Li, C., Liu, W., & Liu, H.
Venue
Advanced Science
Publisher
Wiley
Published
2020-08-19
Volume
7
Issue
18
Pages
2000154-2000154
ISSN
2198-3844 (ISSN-L)
OpenAlex
W3080610517
Cited by
199
References
11
FWCI
7.08
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.