Comparison of different bioelectrical impedance analyzers in the prediction of body composition
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To investigate the influence of different bioelectrical impedance (BI) analyzers on the prediction of body composition from bioelectrical resistive impedance (R), 146 healthy white adults (73 men; 73 women) were studied at two independent laboratories: The University of Florida (UF) and the USDA, San Francisco. Whole body R was measured on each subject with three different BI analyzers. AT UF analyzers were: Valhalla Scientific model 1990‐A (VH), RJL Systems model BIA‐101 (RJL), and Medi‐Fitness model 1000 (MF). At USDA analyzers were: VH, RJL, and Bioelectrical Sciences model 200Z (BES). The largest difference in R (36 ohms, P ⩽ 0.01) was noted between BES and VH at USDA. When applied to current BI prediction equations, the observed differences among analyzers resulted in differences in predicated % fat of up to 6.3% although most comparisons among mean values (79%) showed differences below 3%. Crossvalidation of the selected BI prediction equations with hydrostatistically determines body composition using the different R values revealed total errors of prediction (E) ranging from 3.6 to 9.8% fat. The prediction equations were most accurate when used with data collected on the same instrument that was to used to develop the equation (E = 3.6 to 5.3% fat). These findings indicate that different analyzers can be a significant source of variation when predicting body composition from R. To minimize this source of variation, it is recommended that BI prediction equations be used with the same type of instrument as that with which they were developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Cited by
Bioelectrical Impedance Analysis: A Review of Principles and Applications
Kushner, R. F. (1992) · Journal of the American College of Nutrition · doi:10.1080/07315724.1992.12098245 · Cited by 625
Single prediction equation for bioelectrical impedance analysis in adults aged 20–94 years
Kyle, U. G., Genton, L., Karsegard, L., Slosman, D. O., & Pichard, C. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00553-0 · Cited by 575
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Self-citationWood, N., Johnson, R. B., & Streckfus, C. F. (2003) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.2003.00353.x · Cited by 282
Campa, F., Gobbo, L. A., Stagi, S., Cyrino, L. T., Toselli, S., Marini, E., & Coratella, G. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-021-04879-y · Cited by 115
Metadata
- Authors
- Graves, J. E., Pollock, M. L., Colvin, A. B., Van Loan, M., & Lohman, T. G.
- Venue
- American Journal of Human Biology
- Publisher
- Wiley
- Published
- 1989-01
- Volume
- 1
- Issue
- 5
- Pages
- 603-611
- ISSN
- 1042-0533 (ISSN-L)
- 1520-6300
- OpenAlex
- W2124285212
- Cited by
- 83
- References
- 2
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.